High-field magnetic resonance imaging using solenoid radiofrequency coils

被引:5
作者
Vegh, Viktor [1 ]
Glaeser, Philipp [1 ]
Maillet, Donald [1 ]
Cowin, Gary J. [1 ]
Reutens, David C. [1 ]
机构
[1] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld, Australia
关键词
Micro-coil; Micron resolution; Magnetic resonance imaging; Rat kidney; RADIO-FREQUENCY COIL; NMR PROBE DESIGN; RESOLUTION; SENSITIVITY; SAMPLES; MRI;
D O I
10.1016/j.mri.2012.04.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. Image quality was quantified using signal-to-noise ratio and signal variation over regions of interest. Benchmarking was conducted using 5-mm diameter coils, as this size is comparable to an established coil of the same size. Our 1.4-mm-diameter coils were compared directly to each other, from which we deduce performance as a function of conductor material and coating. A variety of materials and conductor coatings allowed us to choose an optimal design, which we used to image a kidney section at 10-micron resolution. We applied zero-fill extrapolation to achieve 5-micron resolution. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:1177 / 1185
页数:9
相关论文
共 22 条
  • [1] Bruker-Biospin, 2011, PAR
  • [2] Radio frequency coil technology for small-animal MRI
    Doty, F. David
    Entzminger, George
    Kulkarni, Jatin
    Pamarthy, Kranti
    Staab, John P.
    [J]. NMR IN BIOMEDICINE, 2007, 20 (03) : 304 - 325
  • [3] Doty FD, 1998, CONCEPT MAGNETIC RES, V10, P239, DOI 10.1002/(SICI)1099-0534(1998)10:4<239::AID-CMR2>3.0.CO
  • [4] 2-Y
  • [5] Doty FD, 1998, CONCEPT MAGNETIC RES, V10, P133, DOI 10.1002/(SICI)1099-0534(1998)10:3<133::AID-CMR1>3.0.CO
  • [6] 2-Y
  • [7] Haacke E.M., 1999, Magnetic Resonance Imaging: Physical Principles and Sequence Design
  • [8] Jacobsen NE, 2007, NMR SPECTROSCOPY EXPLAINED: SIMPLIFIED THEORY, APPLICATIONS AND EXAMPLES FOR ORGANIC CHEMISTRY AND STRUCTURAL BIOLOGY, P1, DOI 10.1002/9780470173350
  • [9] Reducing the NMR sample volume using a single organic liquid: Increased sensitivity for mass-limited samples with standard NMR probes
    Jarrell, H. C.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2009, 198 (02) : 204 - 208
  • [10] High-resolution liquid- and solid-state nuclear magnetic resonance of nanoliter sample volumes using microcoil detectors
    Kentgens, A. P. M.
    Bart, J.
    van Bentum, P. J. M.
    Brinkmann, A.
    Van Eck, E. R. H.
    Gardeniers, J. G. E.
    Janssen, J. W. G.
    Knijn, P.
    Vasa, S.
    Verkuijlen, M. H. W.
    [J]. JOURNAL OF CHEMICAL PHYSICS, 2008, 128 (05)