A New Design of a Lead-Acrylic Shield for Staff Dose Reduction in Radial and Femoral Access Coronary Catheterization

被引:9
作者
Eder, H. [1 ]
Seidenbusch, M. C. [2 ]
Treitl, M. [2 ]
Gilligan, P. [3 ]
机构
[1] Univ Munich, Formerly Bavarian Off Occupat Hlth & Safety, Dept Radiat Protect, Munich, Germany
[2] Univ Munich, Ctr Clin, Inst Clin Radiol, Munich, Germany
[3] Mater Private Hosp, Med Phys, Dublin, Ireland
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2015年 / 187卷 / 10期
关键词
coronary angiography; radiation safety; physics; technical aspects; PROTECTION;
D O I
10.1055/s-0034-1399688
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Today's standard radiation protection during coronary angiography and percutaneous coronary interventions is the combined use of lead acrylic shields and table-mounted lower body protection. Ambient dose measurements, however, have shown that these protection devices need improvement. Materials and Methods: Using an anthropomorphic physical phantom, various scenarios were investigated with respect to personnel exposure: a) enlarging the shield b) adding a flexible protective curtain to the bottom side of the shield, and c) application of radioprotective patient drapes. For visualization of the dose reduction effect, Monte Carlo simulations were performed. Results: The flexible curtain in contact with the patient's body reduces the ambient dose rate at the operator's position by up to (87.5% +/- 7.1) compared to the situation with the bare shield. The use of both the flexible curtain and the patient drape reduces the ambient dose rate by up to (90.8% +/- 7). Similar results were achieved for the assisting personnel when they were positioned next to the operator. In addition, the enlarged shield provides better protection of the head region of tall operators. Conclusion: Adding a flexible protective curtain to the bottom side of the shield can protect operators from high doses, especially for body parts which are not protected by lead aprons, e.g. head, and eye lenses. This may be important with respect to lower dose limits for eye lenses in future. The protective effect in real-life working conditions is still being evaluated in an ongoing clinical study.
引用
收藏
页码:915 / 923
页数:9
相关论文
共 17 条
  • [1] [Anonymous], 2008, INT RAD
  • [2] COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR
    BIRCH, R
    MARSHALL, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) : 505 - 517
  • [3] Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED project
    Donadille, L.
    Carinou, E.
    Brodecki, M.
    Domienik, J.
    Jankowski, J.
    Koukorava, C.
    Krim, S.
    Nikodemova, D.
    Ruiz-Lopez, N.
    Sans-Merce, M.
    Struelens, L.
    Vanhavere, F.
    Zaknoune, R.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1203 - 1209
  • [4] Ertel A, 2012, RAD DOSE REDUCTION R
  • [5] Radiation protection in interventional radiology
    Faulkner, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (832) : 325 - 326
  • [6] Radiation protection in interventional radiology
    Johnson, DR
    Kyriou, J
    Morton, EJ
    Clifton, A
    Fitzgerald, M
    MacSweeney, E
    [J]. CLINICAL RADIOLOGY, 2001, 56 (02) : 99 - 106
  • [7] Kleinschmidt C, 2001, Z Med Phys, V11, P119
  • [8] Effective dose to staff from interventional procedures: estimations from single and double dosimetry
    Kuipers, Gerritjan
    Velders, Xandra L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2009, 136 (02) : 95 - 100
  • [9] Reduction of Operator Radiation Dose by a Pelvic Lead Shield During Cardiac Catheterization by Radial Access Comparison With Femoral Access
    Lange, Helmut W.
    von Boetticher, Heiner
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) : 445 - 449
  • [10] Nelson WR, 1985, EGS4 SYSTEM VERSION4, P265