Determination of Traces of 2,4-Dichlorophenoxy Acetic Acid in Environmental Samples

被引:0
作者
Maleki, N. [1 ]
Safavi, A. [1 ]
Hasanpour, F. [1 ]
Shahbaazi, H. R. [2 ]
机构
[1] Shiraz Univ, Coll Sci, Dept Chem, Shiraz 71454, Iran
[2] Chem & Mfg Pakshoo Co, Tehran, Iran
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensitive determination of 2,4-dichlorophenoxy acetic acid (2,4-D) was studied at a static mercury drop electrode in aqueous media and in the presence of Britton-Robinson buffer as the electrolyte. In this study, the electroinactive 2,4-D was first converted to electroactive nitrated 2,4-D. Subsequent determination was carried out by differential pulse polarography. Under optimum conditions (pH = 11; v = 90 mV s(-1); modulation amplitude = 120 mV), the relative standard deviation was 4.5% and limit of detection in terms of nitrated 2,4-D was 5 mu g L-1 (1.88 x 10(-8) M) with linear concentration range from 8 to 300 mu g L-1(3 x 10(-8) - 1.12 x 10(-6)M). The proposed method offered high sensitivity as well as good selectivity. A mechanistic study, showed four-electron reduction of nitrated 2,4-D to its hydroxylamine derivative. The proposed method was, also, applied to the determination of 2,4-D in environmental samples such as soil samples.
引用
收藏
页码:430 / 434
页数:5
相关论文
共 22 条
[11]   Voltammetric behaviour of some nitropesticides at the mercury drop electrode [J].
Kotoucek, M ;
Opravilova, M .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :73-81
[12]   Electrochemical determination of 2,4-D at a mercury electrode [J].
Maleki, N ;
Safavi, A ;
Shahbaazi, HR .
ANALYTICA CHIMICA ACTA, 2005, 530 (01) :69-74
[13]   The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopy [J].
Navrátilová, I ;
Skládal, P .
BIOELECTROCHEMISTRY, 2004, 62 (01) :11-18
[14]   Optimisation of a gas chromatographic-mass spectrometric method for the determination of phenoxy acid herbicides in water samples as silyl derivatives [J].
Pereiro, IR ;
Irimia, RG ;
Cano, ER ;
Torrijos, RC .
ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) :249-256
[15]   Flow injection analysis of mercury(II) based on enzyme inhibition and thermometric detection [J].
Pirvutoiu, S ;
Surugiu, I ;
Dey, ES ;
Ciucu, A ;
Magearu, V ;
Danielsson, B .
ANALYST, 2001, 126 (09) :1612-1616
[16]   Determination of the herbicide 4-chloro-2-methylphenoxyacetic acid and its main metabolite, 4-chloro-2-methylphenol in water and soil by liquid chromatography-electrospray tandem mass spectrometry [J].
Pozo, O ;
Pitarch, E ;
Sancho, JV ;
Hernández, F .
JOURNAL OF CHROMATOGRAPHY A, 2001, 923 (1-2) :75-85
[17]   Optimized derivatization of acidic herbicides with trimethylsilyldiazomethane for GC analysis [J].
Ranz, Andreas ;
Korpecka, Justyna ;
Lankmayr, Ernst .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (04) :746-752
[18]   Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection [J].
Rosales-Conrado, N. ;
Leon-Gonzalez, M. E. ;
Perez-Arribas, L. V. ;
Polo-Diez, L. M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) :759-768
[19]  
Schaner A, 2007, J AOAC INT, V90, P1402
[20]  
SCHUETZ AJ, 1998, P 10 INT S 1998, P67