Highly sensitive nonenzymatic glucose and H2O2 sensor based on Ni(OH)2/electroreduced graphene oxide-Multiwalled carbon nanotube film modified glass carbon electrode

被引:124
作者
Gao, Wei [1 ]
Tjiu, Weng Weei [2 ]
Wei, Junchao [1 ]
Liu, Tianxi [1 ]
机构
[1] Fudan Univ, Dept Macromol Sci, State Key Lab Mol Engn Polymers, Shanghai 200433, Peoples R China
[2] ASTAR, Inst Mat Res & Engn, Singapore 117602, Singapore
基金
中国国家自然科学基金;
关键词
Graphene; Multiwalled carbon nanotubes; Ni(OH)(2); Glucose sensor; Hydrogen peroxide sensor; HYDROGEN-PEROXIDE DETECTION; CO-REDUCTION SYNTHESIS; ELECTROCHEMICAL SENSORS; ENZYME-FREE; NANOPARTICLES; FUNCTIONALIZATION; NANOCOMPOSITES; PERFORMANCE; DISPERSION; NANOSHEETS;
D O I
10.1016/j.talanta.2013.12.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, a nonenzymatic sensor based on Ni(OH)(2)/electroreduced graphene oxide (ERGO)-multiwalled carbon nanotube (MWNT) nanocomposites is fabricated via convenient electrodeposition of Ni(OH)(2) nanoparticles on ERGO-MWNT film modified glass carbon electrode (GCE). Graphene oxide (GO) sheets can serve as surfactants to stabilize the dispersion of pristine MWNTs in aqueous solution, rendering a fine coverage of ERGO-MWNT film on GCE during the fabrication process. MWNTs perform as conducting bridges between ERGO sheets to enhance the electron transfer rate in the substrate. By combining the advantages of ERGO and MWNTs, together with electrocatalytic effect of Ni(OH)(2) nanoparticles, the well-designed nanocomposites exhibit excellent sensing behavior towards glucose and hydrogen peroxide (H2O2). The linear detection ranges for glucose and H2O2 are 10-1500 mu M and 10 mu M-9050 mu M while the detection limits are 2.7 mu M and 4.0 mu M, respectively. Furthermore, a very high sensitivity is achieved with 2042 mu Am M-1 cm(-2) estimated for glucose and 711 mu Am M-1 cm(-2) for H2O2. These results suggest that Ni(OH)(2)/ERGO-MWNT nanocomposites thus easily prepared through a green electrochemical method are promising electrode materials for biosensing. Additionally, good recoveries of analytes in real samples like urine and milk confirm the reliability of the prepared sensor in practical applications. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:484 / 490
页数:7
相关论文
共 39 条
[1]   Preparation of platinum/carbon nanotube in aqueous solution by femtosecond laser for non-enzymatic glucose determination [J].
Chang, Han-Wei ;
Tsai, Yu-Chen ;
Cheng, Chung-Wei ;
Lin, Cen-Ying ;
Wu, Ping-Han .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 :34-39
[2]   Electrochemical Behavior of Hydrogen Peroxide at a Glassy Carbon Electrode Modified with Nickel Hydroxide-Decorated Multiwalled Carbon Nanotubes [J].
Chang, Yan ;
Qiao, Jie ;
Liu, Qiaoling ;
Shangguan, Lingzhi ;
Ma, Xuwen ;
Shuang, Shaomin ;
Dong, Chuan .
ANALYTICAL LETTERS, 2008, 41 (17) :3147-3160
[3]   Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite [J].
Chen, Jin ;
Zhang, Wei-De ;
Ye, Jian-Shan .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) :1268-1271
[4]   Bimetallic PtM (M = Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for H2O2 [J].
Chen, Kuan-Jung ;
Pillai, K. Chandrasekara ;
Rick, John ;
Pan, Chun-Jern ;
Wang, Shih-Han ;
Liu, Chung-Chiun ;
Hwang, Bing-Joe .
BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) :120-127
[5]   Arrayed CNT-Ni nanocomposites grown directly on Si substrate for amperometric detection of ethanol [J].
Chen, Yan-Shi ;
Huang, Jin-Hua .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :207-212
[6]  
Cu A.X., 2010, ELECTROCHIM ACTA, V55, P7182
[7]   Electrochemical co-reduction synthesis of graphene/Au nanocomposites in ionic liquid and their electrochemical activity [J].
Fu, Chaopeng ;
Kuang, Yafei ;
Huang, Zhongyuan ;
Wang, Xiao ;
Du, Nana ;
Chen, Jinhua ;
Zhou, Haihui .
CHEMICAL PHYSICS LETTERS, 2010, 499 (4-6) :250-253
[8]   Aqueous dispersions of reduced graphene oxide and multi wall carbon nanotubes for enhanced glucose oxidase bioelectrode performance [J].
Grosse, Willo ;
Champavert, Joffrey ;
Gambhir, Sanjeeu ;
Wallace, Gordon G. ;
Moulton, Simon E. .
CARBON, 2013, 61 :467-475
[9]   A Green Approach to the Synthesis of Graphene Nanosheets [J].
Guo, Hui-Lin ;
Wang, Xian-Fei ;
Qian, Qing-Yun ;
Wang, Feng-Bin ;
Xia, Xing-Hua .
ACS NANO, 2009, 3 (09) :2653-2659
[10]   Multiwall carbon nanotube modified glassy carbon electrode as voltammetric sensor for the simultaneous determination of ascorbic acid and caffeine [J].
Gupta, Vinod Kumar ;
Jain, Ajay Kumar ;
Shoora, Sudhir Kumar .
ELECTROCHIMICA ACTA, 2013, 93 :248-253