共 22 条
Relative biological efficiency of protons at low and therapeutic doses in induction of 53BP1/γH2AX foci in lymphocytes from umbilical cord blood
被引:14
作者:
Sorokina, Svetlana
[1
,2
]
Markova, Eva
[1
]
Gursky, Jan
[1
]
Dobrovodsky, Jozef
[3
]
Belyaev, Igor
[1
,4
]
机构:
[1] Slovak Acad Sci, Canc Res Inst, Bratislava 83391, Slovakia
[2] Russian Acad Sci, Inst Theoret & Expt Biophys, Lab Cytogenet, Pushchino 142292, Russia
[3] Slovak Inst Metrol, Bratislava, Slovakia
[4] Russian Acad Sci, Inst Gen Phys, Radiobiol Lab, Moscow, Russia
关键词:
Protons;
cord blood lymphocytes;
DNA double-strand breaks;
DOUBLE-STRAND BREAKS;
DNA-DAMAGE;
BEAM THERAPY;
ION-BEAMS;
X-RAYS;
RADIATION;
CELLS;
FIBROBLASTS;
QUALITY;
CANCER;
D O I:
10.3109/09553002.2013.797619
中图分类号:
Q [生物科学];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Purpose : In order to evaluate DNA damage induced by protons at low and radiotherapeutic doses at the therapeutic proton complex at Ruzomberok, Slovak Republic, lymphocytes from umbilical cord blood (UCB) of the same four probands were irradiated in the dose range of 1-200 cGy with gamma-rays and protons (200 MeV, irradiation in the Bragg peak). Materials and methods : DNA repair gamma H2AX/53BP1 foci were analyzed by fluorescent microscopy and flow cytometry. Results : Statistically significant effects of radiations were detected by fluorescent microscopy at all doses higher 1 cGy. Almost all distributions of foci in irradiated cells fitted to the Poisson distribution. In general, there was no difference in the levels of gamma H2AX and 53BP1 foci in irradiated cells. Flow cytometry was less sensitive and detected radiation induced effects at doses of 50 cGy and higher. Factorial analysis of variance in the whole studied dose range has shown no significant effect of radiation quality on number of gamma H2AX and 53BP1 foci. The ratio of proton-induced foci to gamma-ray-induced foci was 0.86 +/- 0.16 (53BP1) and 0.99 +/- 0.34 (gamma H2AX) as measured by fluorescent microscopy and 0.99 +/- 0.16 (gamma H2AX) as measured by flow cytometry at the radiotherapeutic dose of 2 Gy. Conclusions : Both flow cytometry and fluorescent microscopy indicated that the average value of relative biological efficiency (RBE) at radiation doses >= 20 cGy was about 1.0. Our data that RBE increased at low doses < 20 cGy are relevant both to the development of treatment modalities and exposures that take place during space exploration and should be verified by further studies.
引用
收藏
页码:716 / 723
页数:8
相关论文