Influence of surface roughness on the bond of FRP laminates to concrete

被引:99
作者
Iovinella, Ivano [1 ]
Prota, Andrea [1 ]
Mazzotti, Claudio [2 ]
机构
[1] Univ Naples Federico II, Dept Struct Eng, I-80125 Naples, Italy
[2] Univ Bologna, DICAM, I-40136 Bologna, Italy
关键词
FRP; Surface preparations; Roughness; Pull out; Profilometer; Fracture energy;
D O I
10.1016/j.conbuildmat.2012.09.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The potential of Fiber Reinforced Polymer FRP in the reinforcement of concrete structures has been shown in many studies and practical applications. However, few works have been focused systematically on the development of quantitative criteria to measure surface roughness and relate this parameter to the debonding stress. Roughness has a direct influence on the FRP performance in terms of bond to concrete, which is important to ensure the effectiveness of the external FRP reinforcement. Currently, there is not much evidence about the parameters related to surface state of concrete structures nor many guidelines about assessing the optimal conditions of concrete surface for the application of the FRP. To respond to these needs, the presented study deals with the effects of the surface characteristics of concrete on debonding strength of the FRP; this objective has been pursued by means of experimental tests on concrete specimens characterized by different levels of roughness of the concrete surface. The paper describes the experimental campaign outlining the analyzed surface preparation procedures (i.e., sandblast, bush-ammering, grinding, brushing) and the subsequent tests performed on the installed FRP by means of two different test methods. The former is a laboratory method which performs shear tests to evaluate the debonding shear strength of the FRP reinforcement; the latter is pull-out test which is a typical method used for in situ check of quality of the FRP application. The results of these experimental tests are discussed in the paper with emphasis on the correlation between the roughness of the surface and the outcomes of both shear and pull-out tests; this information can be used in design in order to prescribe the minimum roughness level necessary to attain the expected debonding strength of the reinforcement. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:533 / 542
页数:10
相关论文
共 25 条
[11]  
Iovinella I, 2009, THESIS U NAPLES FEDE
[12]  
Italian National Research Council, Technical Guideline No. 200/2004
[13]   Bond-slip models for FRP sheets/plates bonded to concrete [J].
Lu, XZ ;
Teng, JG ;
Ye, LP ;
Jiang, JJ .
ENGINEERING STRUCTURES, 2005, 27 (06) :920-937
[14]  
Maerz N.H., 1990, THESIS U WATERLOO
[15]   An experimental study on delamination of FRP plates bonded to concrete [J].
Mazzotti, C. ;
Savoia, M. ;
Ferracuti, B. .
CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (07) :1409-1421
[16]   A new single-shear set-up for stable debonding of FRP-concrete joints [J].
Mazzotti, C. ;
Savoia, M. ;
Ferracuti, B. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (04) :1529-1537
[17]  
Miller B, 1999, MATERIALS AND CONSTRUCTION: EXPLORING THE CONNECTION, P240
[18]  
Miller B, 1999, STRUCTURAL FAULTS RE
[19]  
Miller B, 1999, THESIS U MISSOURI RO
[20]   Modeling of flexural behavior of RC beams strengthened with mechanically fastened FRP strips [J].
Nardone, Fabio ;
Lignola, Gian Piero ;
Prota, Andrea ;
Manfredi, Gaetano ;
Nanni, Antonio .
COMPOSITE STRUCTURES, 2011, 93 (08) :1973-1985