Flow-injection method for the determination of iodide/iodine using Ru(bpy)33+-NADH chemiluminescence detection

被引:10
作者
Waseem, Amir [1 ]
Yaqoob, Mohammad [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; Ru(bpy)(3)(2+); chemiluminescence; iodide/iodine; iodized salts; pharmaceuticals;
D O I
10.1002/bio.1037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A two-channel flow-injection (FI) method is reported for the determination of iodide and iodine by its enhancement effect on the Ru(bpy)(3)(3+)-NADH chemiluminescence (CL) system. The limit of detection (3 s of blank) was 1.0 x 10(-9) mol/L iodide/iodine, with a sample throughput of 60/h. The calibration graphs over the range 1.0-50 x 10(-8) mol/L gave correlation coefficients of 0.9994 and 0.999 (n = 5) with relative standard deviations (RSD; n = 4) of 1.0-2.5%, respectively. The effects of interfering cations, anions and some organic compounds were also studied. The method was applied to iodized salts and pharmaceutical samples and the results obtained were in good agreement with the value quoted. The CL method developed was compared with spectrophotometric method. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:316 / 320
页数:5
相关论文
共 27 条
[1]   Head-space flow injection for the on-line determination of iodide in urine samples with chemiluminescence detection [J].
Burguera, JL ;
Brunetto, MR ;
Contreras, Y ;
Burguera, M ;
Gallignani, M ;
Carrero, P .
TALANTA, 1996, 43 (06) :839-850
[2]   Use of pseudo-first order kinetics in flow injection for determination of trace inorganic iodine [J].
Choengchan, N ;
Lukkanakul, K ;
Ratanawimarnwong, N ;
Waiyawat, W ;
Wilairata, P ;
Nacapricha, D .
ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) :115-122
[3]   Simple flow injection system for colorimetric determination of iodate in iodized salt [J].
Choengchan, N ;
Uraisin, K ;
Choden, K ;
Veerasaia, W ;
Grudpan, K ;
Nacaprich, D .
TALANTA, 2002, 58 (06) :1195-1201
[4]  
ERBAO L, 2002, J ANAL SCI, V18, P207
[5]   An improved method for the flow-injection determination of iodine using the luminol chemiluminescence reaction in a reversed micellar medium of cetyltrimethylammonium chloride in 1-hexanol-cyclohexane [J].
Fujiwara, T ;
Mohammadzai, IU ;
Kojima, M ;
Kumamaru, T .
ANALYTICAL SCIENCES, 2006, 22 (01) :67-71
[6]   Trends in the analytical applications of chemiluminescence in the liquid phase [J].
Garcia-Campana, Ana M. ;
Lara, Francisco J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :165-169
[7]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41
[8]   Two chemical approaches for the production of stable solutions of tris(2,2′-bipyridyl)ruthenium(III) for analytical chemiluminescence [J].
Gerardi, RD ;
Barnett, NW ;
Jones, P .
ANALYTICA CHIMICA ACTA, 1999, 388 (1-2) :1-10
[9]  
Haldimann M, 1998, CLIN CHEM, V44, P817
[10]  
HE YH, 2001, CHIN J ANAL LAB, V20, P70