A general distributed-parameter model for thermal performance of cold box with parallel plate-fin heat exchangers based on graph theory

被引:13
作者
Sun, Haoran [1 ]
Hu, Haitao [1 ]
Ding, Guoliang [1 ]
Chen, Hui [2 ]
Zhang, Zhigang [3 ]
Wu, Chunlin [3 ]
Wang, Lichun [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Shanxi Fenxi Heavy Ind Co Ltd, Taiyuan 030027, Shanxi, Peoples R China
[3] Shanxi Fenxi Electromech Co Ltd, Taiyuan 030027, Shanxi, Peoples R China
关键词
Distributed-parameter; Cold box; Plate-fin heat exchanger; Model; Graph theory; GAS LIQUEFACTION PROCESS; PRESSURE-DROP; OPTIMIZATION; SIMULATION; SINGLE; DESIGN; CONDUCTION;
D O I
10.1016/j.applthermaleng.2018.11.054
中图分类号
O414.1 [热力学];
学科分类号
摘要
For predicting the thermal performance of cold box with parallel plate-fin heat exchangers, a general distributed-parameter model based on graph theory was developed. In the present study, a mathematical description model of cold box based on graph theory was established, capable of describing the connection relations of multiple streams and components in cold box; a distributed-parameter thermal performance model of plate-fin heat exchangers based on approximate analytical method was developed, and the temperature gradients along both axial and transversal directions are reflected; a mass flow rate distribution model of parallel pipelines based on the pressure balance was presented to calculate the flow distribution of multiple streams in pipelines. A tailor-made iteration algorithm using graph-based traversal method was developed to solve the present model. The validation of the proposed model shows that the deviations of the calculated heat capacity and outlet temperature of natural gas from experimental data are -1.9% and +4.35 degrees C, respectively.
引用
收藏
页码:478 / 490
页数:13
相关论文
共 37 条
[31]  
Wilhelmsen O., 2018, INT J HYDROGEN ENERG
[32]   Bi-level optimizing operation of natural gas liquefaction process [J].
Won, Wangyun ;
Kim, Jiyong .
COMPUTERS & CHEMICAL ENGINEERING, 2017, 96 :87-102
[33]   Automatically varying the composition of a mixed refrigerant solution for single mixed refrigerant LNG (liquefied natural gas) process at changing working conditions [J].
Xu, Xiongwen ;
Liu, Jinping ;
Cao, Le ;
Pang, Weiqiang .
ENERGY, 2014, 64 :931-941
[34]   The correlation between mixed refrigerant composition and ambient conditions in the PRICO LNG process [J].
Xu, Xiongwen ;
Liu, Jinping ;
Jiang, Chuanshuo ;
Cao, Le .
APPLIED ENERGY, 2013, 102 :1127-1136
[35]   A distributed parameter model and its application in optimizing the plate-fin heat exchanger based on the minimum entropy generation [J].
Zhang, Lina ;
Yang, Chunxin ;
Zhou, Jianhui .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (08) :1427-1436
[36]   Fluid Flow Distribution and Heat Transfer in Plate-Fin Heat Exchangers [J].
Zhang, Zhe ;
Mehendale, Sunil ;
Tian, Jinjin ;
Li, Yanzhong .
HEAT TRANSFER ENGINEERING, 2015, 36 (09) :806-819
[37]   New integral-mean temperature difference model for thermal design and simulation of parallel three-fluid heat exchanger [J].
Zhao, Min ;
Li, Yanzhong .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 59 :203-213