Asymmetry assessment using cone beam CT A Class I and Class II patient comparison

被引:20
|
作者
Sievers, Matthew M.
Larson, Brent E. [1 ]
Gaillard, Philippe R. [2 ]
Wey, Andrew [2 ]
机构
[1] Univ Minnesota, Sch Dent, Div Orthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Clin & Translat Sci Inst, Biostat Design & Anal Ctr, Minneapolis, MN USA
关键词
Asymmetry assessment; Cone-beam; CBCT; 3 dimensional analysis; Facial asymmetry; CEPHALOMETRIC LANDMARK IDENTIFICATION; COMPUTED-TOMOGRAPHY; RELIABILITY; ACCURACY; PRECISION;
D O I
10.2319/041711-271.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To estimate possible differences in skeletal asymmetry between patients with skeletal Class I and skeletal Class II relationships. Materials and Methods: Cone beam computed tomography (CBCT) images were examined from 70 consecutive patients who presented for orthodontic care and fit the inclusion criteria. Asymmetry was quantified using an asymmetry index developed by Katsumata et al. Anatomic landmarks were defined and reference planes were established to determine the asymmetry of the landmarks using a constructed coordinate plane system. Thirty randomly selected patients were reanalyzed to assess the reliability of the method. Results: Statistical analysis did not find any significant relationship between asymmetry and A-P skeletal relationship for any of the landmarks. Asymmetry index scores were reproducible within a certain range of agreement for each landmark. Conclusions: Based on this study, the discrepant jaw growth resulting in a Class II skeletal pattern results in no more skeletal asymmetry than Class I skeletal patterns. (Angle Orthod. 2012;82:410-417.)
引用
收藏
页码:410 / 417
页数:8
相关论文
共 50 条
  • [31] A comparison of weight histories in women with class III vs. class I-II obesity
    Crerand, Canice E.
    Wadden, Thomas A.
    Sarwer, David B.
    Fabricatore, Anthony N.
    Kuehnel, Robert H.
    Gibbons, Lauren M.
    Brock, Johanna R.
    Williams, Noel N.
    OBESITY, 2006, 14 : 63S - 69S
  • [32] The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT
    Yamashina, A.
    Tanimoto, K.
    Sutthiprapaporn, P.
    Hayakawa, Y.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (05) : 245 - 251
  • [33] Cone-beam evaluation of pharyngeal airway space in adult skeletal Class II patients with different condylar positions
    Xu, Jintao
    Sun, Ruonan
    Wang, Linna
    Hu, Xiaoying
    ANGLE ORTHODONTIST, 2019, 89 (02) : 312 - 316
  • [34] Comparison of the occlusal contact area of virtual models and actual models: a comparative in vitro study on Class I and Class II malocclusion models
    Lee, Hyemin
    Cha, Jooly
    Chun, Youn-Sic
    Kim, Minji
    BMC ORAL HEALTH, 2018, 18
  • [35] Comparison efficiency of posteroanterior cephalometry and cone-beam computed tomography in detecting craniofacial asymmetry: A systematic review
    Yousefi, Faezeh
    Rafiei, Elahe
    Mahdian, Mina
    Mollabashi, Vahid
    Saboonchi, Seyedeh Shabnam
    Hosseini, Seyed Mehdi
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (02) : 358 - 371
  • [36] Comparison of panoramic radiography and cone beam CT in the assessment of juxta-apical radiolucency
    Leandro Nascimento, Eduarda Helena
    Costa Oenning, Anne Caroline
    Freire, Bernardo Barbosa
    Gaeta-Araujo, Hugo
    Haiter-Neto, Francisco
    Freitas, Deborah Queiroz
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (01)
  • [37] Hard and Soft Tissue Asymmetry in Patients with Skeletal Class III Malocclusion: A Cone-Beam Computed Tomography Study
    Tam, Tim King Man
    Guo, Runzhi
    Liu, Hao
    Lin, Yifan
    DIAGNOSTICS, 2023, 13 (05)
  • [38] Comparison of 96-kV and 120-kV cone-beam CT for the assessment of cochlear implants
    Burck, Iris
    Yel, Ibrahim
    Martin, Simon
    Albrecht, Moritz H.
    Koch, Vitali
    Booz, Christian
    dos Santos, Daniel Pinto
    Kaltenbach, Benjamin
    Ackermann, Hanns
    Koivisto, Juha
    Helbig, Silke
    Stoever, Timo
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [39] Hindfoot alignment of adult acquired flatfoot deformity: A comparison of clinical assessment and weightbearing cone beam CT examinations
    Netto, Cesar de Cesar
    Shakoor, Delaram
    Roberts, Lauren
    Chinanuvathana, Apisan
    Mousavian, Alireza
    Lintz, Francois
    Schon, Lew C.
    Demehri, Shadpour
    Richter, Martinus
    Netto, Cesar de Cesar
    Lintz, Francois
    Burssens, Arne
    Barg, Alexej
    Buedts, Kris
    Easley, Mark
    Ellis, Scott J.
    Den Hartog, Bryan D.
    Godoy-Santos, Alexandre L.
    Krahenbuhl, Nicola
    Marzo, John M.
    Schon, Lew C.
    Welck, Matthew
    FOOT AND ANKLE SURGERY, 2019, 25 (06) : 790 - 797
  • [40] Patient doses and projection angle in cone beam CT
    He, Wenjun
    Huda, Walter
    Magill, Dennise
    Tavrides, Emily
    Yao, Hai
    MEDICAL PHYSICS, 2010, 37 (05) : 2359 - 2368