Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

被引:4
作者
Trattner, Sigal [1 ,2 ]
Cheng, Bin [3 ]
Pieniazek, Radoslaw L. [2 ,4 ]
Hoffmann, Udo [5 ,6 ]
Douglas, Pamela S. [7 ]
Einstein, Andrew J. [1 ,2 ,8 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] New York Presbyterian Hosp, New York, NY 10032 USA
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY 10032 USA
[4] Columbia Univ, Med Ctr, Ctr Radiol Res, New York, NY 10032 USA
[5] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[6] Harvard Univ, Sch Med, Boston, MA 02114 USA
[7] Duke Univ, Dept Med, Div Cardiol, Durham, NC 27715 USA
[8] Columbia Univ, Med Ctr, Dept Radiol, New York, NY 10032 USA
关键词
effective dose; MOSFET; computer tomography; dosimetry; sample size; CT ANGIOGRAPHY; PHANTOM; TECHNOLOGY;
D O I
10.1118/1.4868693
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen-pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence. (c) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 17 条
  • [1] AAPM, 2011, 204 AAPM TG
  • [2] Establishing a standard calibration methodology for MOSFET detectors in computed tomography dosimetry
    Brady, S. L.
    Kaufman, R. A.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3031 - 3040
  • [3] Response functions for computing absorbed dose to skeletal tissues from photon irradiation
    Eckerman, K. F.
    Boch, W. E.
    Zankl, M.
    Petoussi-Henss, N.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) : 187 - 191
  • [4] Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography
    Einstein, Andrew J.
    Elliston, Carl D.
    Groves, Daniel W.
    Cheng, Bin
    Wolff, Steven D.
    Pearson, Gregory D. N.
    Peters, M. Robert
    Johnson, Lynne L.
    Bokhari, Sabahat
    Johnson, Gary W.
    Bhatia, Ketan
    Pozniakoff, Theodore
    Brenner, David J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 100 - 108
  • [5] Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner
    Einstein, Andrew J.
    Elliston, Carl D.
    Arai, Andrew E.
    Chen, Marcus Y.
    Mather, Richard
    Pearson, Gregory D. N.
    DeLaPaz, Robert L.
    Nickoloff, Edward
    Dutta, Ajoy
    Brenner, David J.
    [J]. RADIOLOGY, 2010, 254 (03) : 698 - 706
  • [6] Conventional and CT angiography in children: dosimetry and dose comparisons
    Frush, Donald P.
    Yoshizumi, Terry
    [J]. PEDIATRIC RADIOLOGY, 2006, 36 (Suppl 2) : 154 - 158
  • [7] State-of-the-art in CT hardware and scan modes for cardiovascular CT
    Halliburton, Sandra
    Arbab-Zadeh, Armin
    Dey, Damini
    Einstein, Andrew J.
    Gentry, Ralph
    George, Richard T.
    Gerber, Thomas
    Mahesh, Mahadevappa
    Weigold, Wm. Guy
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) : 154 - 163
  • [8] A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiology
    Huggett, Jamie
    Mukonoweshuro, William
    Loader, Robert
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 155 (02) : 161 - 168
  • [9] Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols
    Hurwitz, Lynne M.
    Yoshizumi, Terry T.
    Goodman, Philip C.
    Frush, Donald P.
    Nguyen, Giao
    Toncheva, Greta
    Lowry, Carolyn
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) : 544 - 549
  • [10] International Atomic Energy Agency, 2011, IAEA Human Health Reports, V5