Performance of Iterative Image Reconstruction in CT of the Paranasal Sinuses: A Phantom Study

被引:53
作者
Schulz, B. [1 ]
Beeres, M. [1 ]
Bodelle, B. [1 ]
Bauer, R. [1 ]
Al-Butmeh, F. [1 ]
Thalhammer, A. [1 ]
Vogl, T. J. [1 ]
Kerl, J. M. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
DOSE REDUCTION; QUALITY; ANGIOGRAPHY; ALGORITHM;
D O I
10.3174/ajnr.A3339
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: CT in low dose technique is the criterion standard imaging modality for evaluation of the paranasal sinus. Our aim was to evaluate the dose-reduction potential of a recently available sinogram-affirmed iterative reconstruction technique, regarding noise, image quality, and time duration when evaluating this region. MATERIALS AND METHODS: CT was performed on a phantom head at different tube voltages (120 kV, 100 kV) and currents (100 mAs, 50 mAs, 25 mAs). Each protocol was reconstructed (in soft tissue and bony kernel) by using standard filtered back-projection and 5 different SAFIRE strengths, and image noise was evaluated. Subjective image quality was evaluated on noise-aligned image triplets acquired at tube currents of 100% (FBP), 50% (SAFIRE), and 25% (SAFIRE) by using a 5-point scale (1 = worst, 5 = best). The time duration for image reconstruction was noted for calculations with FBP and SAFIRE. RESULTS: SAFIRE reduced image noise by 15%-85%, depending on the iterative strength, rendering kernel, and dose parameters. Noise reduction was stronger at a bone kernel algorithm both in 1- and 3-mm images (P < .05). Subjective quality evaluation of the noise-adapted images showed preference for those acquired at 100% tube current with FBP (4.7-5.0) versus 50% dose with SAFIRE (3.4-4.4) versus 25% dose with SAFIRE (2.0-3.1). The time duration for FBP image sets was 2.9-6.6 images per second versus SAFIRE with 0.9-1.6 images per second. CONCLUSIONS: For CT of the paranasal sinus, SAFIRE algorithms are suitable for image-noise reduction. Because image quality decreases with dosage, careful choice of the appropriate iterative method is necessary to achieve an optimal balance between image noise and quality.
引用
收藏
页码:1072 / 1076
页数:5
相关论文
共 16 条
[1]   Conventional sinus radiography compared with CT in the diagnosis of acute sinusitis [J].
Aalokken, TM ;
Hagtvedt, T ;
Dalen, I ;
Kolbenstvedt, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) :60-62
[2]  
Bongartz G, 199916262 EUR, P16262
[3]   Multidetector CT of the paranasal sinus: Potential for radiation dose reduction [J].
Brem, Matthias H. ;
Zamani, Amir A. ;
Riva, Roberto ;
Zou, Kelly H. ;
Rumboldt, Zoran ;
Hennig, Friedrich F. ;
Kikinis, Ron ;
Norbash, Alexander M. ;
Schoepf, U. Joseph .
RADIOLOGY, 2007, 243 (03) :847-852
[4]   Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality [J].
Bulla, Stefan ;
Blanke, Philipp ;
Hassepass, Frederike ;
Krauss, Tobias ;
Winterer, Jan Thorsten ;
Breunig, Christine ;
Langer, Mathias ;
Pache, Gregor .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) :2246-2250
[5]  
Dammann F, 2007, RADIOLOGE, V47, P576, DOI 10.1007/s00117-007-1502-z
[6]   Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography [J].
Funama, Yoshinori ;
Taguchi, Katsuyuki ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Yanaga, Yumi ;
Yamashita, Yasuyuki ;
Awai, Kazuo .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) :480-485
[7]   CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT [J].
Gervaise, Alban ;
Osemont, Benoit ;
Lecocq, Sophie ;
Noel, Alain ;
Micard, Emilien ;
Felblinger, Jacques ;
Blum, Alain .
EUROPEAN RADIOLOGY, 2012, 22 (02) :295-301
[8]   Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space [J].
Hu, X. H. ;
Ding, X. F. ;
Wu, R. Z. ;
Zhang, M. M. .
CLINICAL RADIOLOGY, 2011, 66 (11) :1023-1029
[9]   Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :649-654
[10]   Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction? [J].
Mazonakis, Michalis ;
Tzedakis, Antonis ;
Damilakis, John ;
Gourtsoyiannis, Nicholas .
EUROPEAN RADIOLOGY, 2007, 17 (05) :1352-1357