Extended smart meters-based remote detection method for illegal electricity usage

被引:18
作者
Bat-Erdene, Byambasuren [1 ]
Lee, Bumjoo [2 ]
Kim, Min-Young [3 ]
Ahn, Tae Hong [4 ]
Kim, Donghan [1 ]
机构
[1] Kyung Hee Univ, Dept Elect Engn, Seoul, South Korea
[2] Myongji Univ, Dept Elect Engn, Yongin, South Korea
[3] Kyungpook Natl Univ, Sch Elect Engn & Comp Sci, Taegu, South Korea
[4] Chunnam Techno Univ, Dept Game Dev, Gokseong, South Korea
基金
新加坡国家研究基金会;
关键词
internetworking; mathematical analysis; network servers; power cables; power engineering computing; power supply quality; power system economics; smart meters; mathematical model; time measurement; low-voltage signal; power system feeder; GSM; gateway smart meter; TSM; terminal smart meter; power line carrier; low-voltage power system; AMR; automatic meter reading; electrical energy quality monitor; power delivery system; illegal electricity usage; extended smart meter-based remote detection method; MANAGEMENT;
D O I
10.1049/iet-gtd.2012.0287
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power delivery systems that use power lines can communicate with other electrical systems, monitor the quality of electrical energy and provide an economical solution for automatic meter reading (AMR). Energy meters can be connected to a low-voltage power system by power line carriers for all consumers. Illegal electricity usage in the power delivery system can be easily detected if AMR is installed in the system, which consists of a terminal smart meter (TSM) and a gateway smart meter (GSM). This study proposes a novel remote detection method for illegal electricity usage that uses both TSM and GSM, where the TSM and the GSM are installed on the power system of each consumer and on the node of the power system feeder, respectively. TSM and GSM simultaneously disconnect an electrical source for a very short period of time. After this, the proposed detection method sends a low-voltage signal with a high frequency from the TSM to the GSM during the time of disconnection. Once the signal has passed, the proposed detection method detects illegal electricity usage by measuring the amount of time it was disconnected. This study presents the structure of the proposed detection method as well as the mathematical model, proof, simulation and experimental results.
引用
收藏
页码:1332 / 1343
页数:12
相关论文
共 18 条
[1]  
Ahola J., 2003, THESIS ACTA U
[2]   LOAD MANAGEMENT AND AUTOMATIC METER READING THROUGH THE USE OF POWER-LINE CARRIER [J].
ARRINGTON, RA .
ELECTRIC POWER SYSTEMS RESEARCH, 1981, 4 (02) :85-104
[3]   A solution to remote detection of illegal electricity usage via power line communications [J].
Cavdar, IH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) :1663-1667
[4]  
Dostert K., 2001, COMMUNICATIONS
[5]  
Ganzorig L., 2010, ANN REPORT 2009 E DI
[6]  
Kirubakaran D., 2009, J IND TECHNOLOGY, V25, P1
[7]  
Larik AS, 2011, MEHRAN UNIV RES J EN, V30, P151
[8]   Experimenting remote kilowatthour meter reading through low-voltage power lines at dense housing estates [J].
Lim, TY ;
Chan, TW .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (03) :708-711
[9]   DESIGN CONSIDERATIONS FOR IMPLEMENTATION OF LARGE-SCALE AUTOMATIC METER READING SYSTEMS [J].
MAK, S ;
RADFORD, D .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) :97-103
[10]   AUTOMATIC METER-READING SYSTEM BY POWER-LINE CARRIER COMMUNICATIONS [J].
MIURA, N ;
SATO, H ;
NARITA, H ;
TAKAKI, M .
IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1990, 137 (01) :25-31