The effect of a combined tube current modulation system on dose delivered to patients undergoing thoracic and abdominal CT with a 128-slice scanner

被引:4
作者
Stratis, A. [1 ]
Kottou, S. [2 ]
Molfetas, M. [3 ]
Xirafi, I. [4 ]
Delis, H. [1 ]
Panayiotakis, G. [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26500, Greece
[2] Univ Athens, Sch Med, Dept Med Phys, GR-11527 Athens, Greece
[3] Evangelismos Gen Hosp, Dept Med Phys, Athens 10676, Greece
[4] Cent Clin Athens, Dept Med Phys, Athens 10680, Greece
关键词
AUTOMATIC EXPOSURE CONTROL; IMAGE QUALITY; SPIRAL CT; COMPUTED-TOMOGRAPHY; ONLINE MODULATION; REDUCTION; OPTIMIZATION; CHILDREN; ABDOMEN; PELVIS;
D O I
10.1093/rpd/ncs301
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Combined tube current modulation techniques (such as Care Dose4D used in this study) during computed tomography (CT) procedures bring together the benefits of the angular and z-axis modulation techniques, measuring X-ray attenuation profile in the z-axis together with the data from the perpendicular xy direction with a sophisticated algorithm. The purpose of this study was to investigate the radiation dose, in terms of computed tomography dose index (CTDIvol), delivered to patients during thoracic and abdominal CT using this technique and compare it with the corresponding CTDIvol of the fixed tube current CT technique. The results revealed a 532 dose reduction for chest CT and a dose reduction of 7.660 for the three-sequence abdominal CT scan of normal and overweight patients. In the case of obese patients a 15.418.7 dose increase for chest CT and a (1.5) (26.3) dose increase for the three-stage abdominal examinations for females and males, respectively, was revealed.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 25 条
[1]   Dose reduction and image quality in MDCT colonography using tube current modulation [J].
Graser, A. ;
Wintersperger, B. J. ;
Suess, C. ;
Reiser, M. F. ;
Becker, C. R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) :695-701
[2]   Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation [J].
Greess, H ;
Lutze, J ;
Nömayr, A ;
Wolf, H ;
Hothorn, T ;
Kalender, WA ;
Bautz, W .
EUROPEAN RADIOLOGY, 2004, 14 (06) :995-999
[3]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[4]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394
[5]   Dose reduction in spiral CT:: Detection of pulmonary nodules with and without anatomic adaptation of tube current. [J].
Greess, H ;
Baum, U ;
Wolf, H ;
Lell, M ;
Nömayr, A ;
Schmidt, B ;
Kalender, WA ;
Bautz, W .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (05) :466-470
[6]  
Greess H., 2006, RADIOLOGY, V225(P), P593
[7]   CT-automatic exposure control devices: What are their performances? [J].
Gutierrez, Daniel ;
Schmidt, Sabine ;
Denys, Alban ;
Schnyder, Pierre ;
Bochud, Francois O. ;
Verdun, Francis R. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :990-995
[8]  
Horiuchi T., 2002, JPN SOC RADIOL TECH, V78, P166
[9]   Chest CT performed with z-axis modulation: Scanning protocol and radiation dose [J].
Kalra, MK ;
Rizzo, S ;
Maher, MM ;
Halpern, EF ;
Toth, TL ;
Shepard, JAO ;
Aquino, SL .
RADIOLOGY, 2005, 237 (01) :303-308
[10]   Techniques and applications of automatic tube current modulation for CT [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Schmidt, B ;
Westerman, BL ;
Morgan, HT ;
Saini, S .
RADIOLOGY, 2004, 233 (03) :649-657