Prospective Evaluation of Passive Expansion of Partially Dilated Transjugular Intrahepatic Portosystemic Shunt Stent Grafts - A Three-Dimensional Sonography Study

被引:45
|
作者
Pieper, Claus Christian [1 ]
Jansen, Christian [2 ]
Meyer, Carsten [1 ]
Nadal, Jennifer [3 ]
Lehmann, Jennifer [2 ]
Schild, Hans Heinz [1 ]
Trebicka, Jonel [2 ]
Thomas, Daniel [1 ]
机构
[1] Univ Bonn, Dept Radiol, Sigmund Freud Str 25, D-53105 Bonn, Germany
[2] Univ Bonn, Dept Internal Med, Sigmund Freud Str 25, D-53105 Bonn, Germany
[3] Univ Bonn, Inst Med Biometry Informat & Epidemiol, Sigmund Freud Str 25, D-53105 Bonn, Germany
基金
欧盟地平线“2020”;
关键词
DIAMETER MEASUREMENT; PORTAL-HYPERTENSION; 3D ULTRASOUND; TIPS; ACCURACY; STENOSIS; QUANTIFICATION; ENCEPHALOPATHY; EXPERIENCE; PHANTOM;
D O I
10.1016/j.jvir.2016.06.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively investigate early expansion kinetics of underdilated self-expanding stent grafts used for transjugular intrahepatic portosystemic shunt (TIPS) creation. Materials and Methods: Twenty patients (7 female; mean age 66 y; range, 31-80 y) with liver cirrhosis undergoing TIPS creation for variceal bleeding (n = 5), refractory ascites (n = 14), or both (n = I) with underdilation of 10-mm stent grafts received two-dimensional (2-D) and three-dimensional (3-D) ultrasound (US) examinations immediately after TIPS creation and I and 6 weeks later. Orthogonal views of the TIPS within the parenchymal tract were reconstructed from 3-D volume data sets acquired in longitudinal orientation of the stent. 2-D images and reconstructed 3-D images were used for blinded diameter measurements. Measurement technique was validated with intrainterventional plain radiographs with a sizing catheter as the gold standard. Diameter changes over time and interrelations with patient characteristics (null hypothesis: no expansion, no interrelation) were analyzed using a general linear model for repeated measures. Results: After dilation to 8-mm diameter, 2-D and 3-D measurements showed stent recoil (mean diameter 7.7 mm 0.21 and 7.6 mm 0.17, respectively). Diameter increased significantly from initial measurements to measurements at I and 6 weeks (2-D, 8.8 mm 0.24 and 9,4 mm 0.15, both P < .001; 3-D, 8.7 mm 0.27 and 9.4 mm 0.11, both P < .001). Validation measurements showed no significant differences between 2-D or 3-D US and gold standard. There were no statistically significant associations between stent expansion and clinical parameters (sex, P = .78; age, P = .82; etiology/grade of cirrhosis, P = .99; indication for TIPS, P = .78, liver stiffness, P = .70). Conclusions: Underdilated self-expanding stent grafts used for TIPS creation significantly expand within first 6 weeks after intervention. These changes can be noninvasively monitored using 3-D US.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 43 条
  • [21] Technical and clinical outcome of transjugular intrahepatic portosystemic stent shunt: Bare metal stents (BMS) versus viatorr stent-grafts (VSG)
    Sommer, Christof M.
    Gockner, Theresa L.
    Stampfl, Ulrike
    Bellemann, Nadine
    Sauer, Peter
    Ganten, Tom
    Weitz, Juergen
    Kauczor, Hans U.
    Radeleff, Boris A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2273 - 2280
  • [22] Long-Term Patency and Clinical Analysis of Expanded Polytetrafluoroethylene-Covered Transjugular Intrahepatic Portosystemic Shunt Stent Grafts
    Weber, Charles N.
    Nadolski, Gregory J.
    White, Sarah B.
    Clark, Timothy W. I.
    Mondschein, Jeffrey I.
    Stavropoulos, S. William
    Shlansky-Goldberg, Richard D.
    Trerotola, Scott O.
    Soulen, Michael C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (09) : 1257 - 1265
  • [23] Transjugular Intrahepatic Portosystemic Shunt in the Treatment of Portal Hypertension Using Memotherm Stents: A Prospective Multicenter Study
    Dirk Domagk
    David Patch
    Robert Dick
    Maurizio Grosso
    Hervé Rousseau
    Philippe Otal
    Pierre Goffette
    Achim Heinecke
    Markus Drees
    Wolfram Domschke
    Josef Menzel
    CardioVascular and Interventional Radiology, 2002, 25 : 506 - 512
  • [24] Comparison Study of Doppler Ultrasound Surveillance of Expanded Polytetrafluoroethylene-Covered Stent versus Bare Stent in Transjugular Intrahepatic Portosystemic Shunt
    Huang, Qian
    Wu, Xingjiang
    Fan, Xinxin
    Cao, Jianmin
    Han, Jianming
    Xu, Lin
    Li, Ning
    JOURNAL OF CLINICAL ULTRASOUND, 2010, 38 (07) : 353 - 360
  • [25] Transjugular intrahepatic portosystemic shunt for portal vein thrombosis with variceal bleeding in liver cirrhosis: outcomes and predictors in a prospective cohort study
    Qi, Xingshun
    He, Chuangye
    Guo, Wengang
    Yin, Zhanxin
    Wang, Jianhong
    Wang, Zhengyu
    Niu, Jing
    Bai, Ming
    Yang, Zhiping
    Fan, Daiming
    Han, Guohong
    LIVER INTERNATIONAL, 2016, 36 (05) : 667 - 676
  • [26] Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft
    Fanelli, Fabrizio
    Bezzi, Mario
    Bruni, Antonio
    Corona, Mario
    Boatta, Emanuele
    Lucatelli, Pierleone
    Passariello, Roberto
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (01) : 100 - 105
  • [27] Course of platelet counts in cirrhotic patients after implantation of a transjugular intrahepatic portosystemic shunt -: a prospective, controlled study
    Gschwantler, M
    Vavrik, J
    Gebauer, A
    Kriwanek, S
    Schrutka-Kölbl, C
    Fleischer, J
    Madani, B
    Brownstone, E
    Tscholakoff, D
    Weiss, W
    JOURNAL OF HEPATOLOGY, 1999, 30 (02) : 254 - 259
  • [28] Economic evaluation of covered stents for transjugular intrahepatic portosystemic stent shunt in patients with variceal bleeding and refractory ascites secondary to cirrhosis
    Mattock, Richard
    Tripathi, Dhiraj
    O'Neill, Frank
    Craig, Joyce
    Tanner, Jennifer
    Patch, David
    Aithal, Guruprasad
    BMJ OPEN GASTROENTEROLOGY, 2021, 8 (01):
  • [29] Prospective evaluation of a clinical score for 60-day mortality after transjugular intrahepatic portosystemic stent-shunt:: Bonn TIPSS early mortality analysis
    Brensing, KA
    Raab, P
    Textor, J
    Görich, J
    Schiedermaier, P
    Strunk, H
    Paar, D
    Schepke, M
    Sudhop, T
    Spengler, U
    Schild, H
    Sauerbruch, T
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2002, 14 (07) : 723 - 731
  • [30] Clinical Efficacy of Transjugular Intrahepatic Portosystemic Shunt Created with Expanded Polytetrafluoroethylene-Covered Stent-Grafts: 8-mm Versus 10-mm
    Luo, Xuefeng
    Wang, Xiaoze
    Zhu, Yongjun
    Xi, Xiaotan
    Zhao, Ying
    Yang, Jinlin
    Li, Xiao
    Yang, Li
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (05) : 737 - 743