Terahertz Imaging Using Swept Source Optical-Coherence-Tomography Techniques

被引:0
|
作者
Ikeou, T. [1 ]
Isogawa, T. [1 ,2 ]
Ajito, K.
Kukutsu, N. [2 ]
Nagatsuma, T. [1 ]
机构
[1] Osaka Univ, Grad Sch Engn Sci, 1-3 Machikaneyama, Toyonaka, Osaka 5608531, Japan
[2] NTT Microsyst Integrat Labs, Atsigi 2430198, Japan
来源
2012 IEEE INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS (MWP) | 2012年
关键词
THz imaging; tomography; swept source optical-coherence-tomography; Mickelson interferometer;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents three-dimensional tomographic imaging using swept-source optical-coherence-tomography (SS-OCT) techniques in the terahertz (THz) region. The system employs photonically generated frequency-tunable THz signals. Operational principle and system configuration of the THz SS-OCT are described, and the first successful tomographic imaging using 250-450 GHz signals is demonstrated.
引用
收藏
页码:290 / 293
页数:4
相关论文
共 50 条
  • [21] Swept-source common-path optical coherence tomography with a MEMS endoscopic imaging probe
    Duan, Can
    Wang, Donglin
    Zhou, Zhengwei
    Liang, Peng
    Samuelson, Sean R.
    Pozzi, Antonio
    Xie, Huikai
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [22] Investigation of Puccinia triticina contagion on wheat leaves using swept source optical coherence tomography
    Rateria, Adya
    Mohan, Muktesh
    Mukhopadhyay, Kunal
    Poddar, Raju
    OPTIK, 2019, 178 : 932 - 937
  • [23] Evaluation of the Cortical Vitreous Using Swept-Source Optical Coherence Tomography in Normal Eyes
    Park, Seung Hun
    Lee, Jung Wook
    Lee, Min Ji
    Lee, Ju Hyang
    Song, In Seok
    Lee, Byung Ro
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (04): : 595 - 600
  • [24] Error rate of automated choroidal segmentation using swept-source optical coherence tomography
    Kong, Mingui
    Eo, Doo Ri
    Han, Gyule
    Park, Sung Yong
    Ham, Don-Il
    ACTA OPHTHALMOLOGICA, 2016, 94 (06) : E427 - E431
  • [25] Observation of Posterior Precortical Vitreous Pocket Using Swept-Source Optical Coherence Tomography
    Itakura, Hirotaka
    Kishi, Shoji
    Li, Danjie
    Akiyama, Hideo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3102 - 3107
  • [26] Simultaneous Topography and Tomography of Microstructures using Full-field Swept-source Optical Coherence Tomography
    Anna, Tulsi
    Shakher, Chandra
    Mehta, Dalip Singh
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 155 - 160
  • [27] Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging
    Chan, Tommy C. Y.
    Biswas, Sayantan
    Yu, Marco
    Jhanji, Vishal
    ACTA OPHTHALMOLOGICA, 2017, 95 (06) : E486 - E494
  • [28] Silver nanoparticles (AgNPs) as a contrast agent for imaging of animal tissue using swept-source optical coherence tomography (SSOCT)
    Mondal, Indranil
    Raj, Shipra
    Roy, Poulomi
    Poddar, Raju
    LASER PHYSICS, 2018, 28 (01)
  • [29] Choroidal thickness in normal Indian eyes using swept-source optical coherence tomography
    Bhayana, Amber A.
    Kumar, Vinod
    Tayade, Akshay
    Chandra, Mahesh
    Chandra, Parijat
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 252 - 255
  • [30] Metrics of Anterior Sclera in Normal Chinese Adults: Anterior Segment Imaging Using the Swept-Source Optical Coherence Tomography
    Lin, Na
    Sun, Yunqi
    Yang, Maoyuan
    Chen, Bichi
    Mao, Jieli
    Liu, Yongshun
    Deng, Ruzhi
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (01): : 23 - 28