Aerogel and krypton insulated evacuated flat-plate collector for process heat production

被引:14
作者
Benz, N
Beikircher, T
Aghazadeh, B
机构
关键词
D O I
10.1016/0038-092X(96)00007-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We investigated the reduction of gas heat conduction in evacuated flat-plate collectors with operating pressures between 10(3) and 10(4) Pa. In stationary heat loss experiments with a real-size model the pressure dependency of the thermal losses was examined for air, krypton and for a nanostructured SiO2-aerogel powder insulation between absorber and rear side of the casing. The theory for pressure dependent gaseous conduction was validated. Due to its high molecular mass, krypton as filling gas reduces gaseous conduction by 65% in the continuum range with respect to air. In a low emissive EFPC where gas conduction losses are comparable to radiative losses, the reduction in the total losses is about 30%. In principle, with unpacked aerogel the heat conduction could be reduced further: the nanostructures affect the gaseous heat conduction to be nearly totally suppressed below 10(2) Pa, because the mean free path of the gas is large compared to the pore dimensions of the aerogel. However, the applied packaging of PTFE-fabric compensates the excellent properties of the insulant due to solid conduction in the fabric. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 7 条
[1]  
AGHAZADEH B, 1995, THESIS L MAXIMILIANS
[2]  
BEIKIRCHER T, 1995, ASME
[3]   USE OF MODERATE VACUUM ENVIRONMENTS AS A MEANS OF INCREASING COLLECTION EFFICIENCIES AND OPERATING TEMPERATURES OF FLAT-PLATE SOLAR COLLECTORS [J].
EATON, CB ;
BLUM, HA .
SOLAR ENERGY, 1975, 17 (03) :151-158
[4]  
FREI U, 1993, LEISTUNGSDATEN THERM
[5]  
FRICKE J, 1994, HEAT TRANSFER 1994, V1, P223
[6]  
Garg H.P., 1987, ADV SOLAR ENERGY TEC, V2
[7]  