Effect of DC electric fields on COD in aerobic mixed sludge processes

被引:49
作者
Alshawabkeh, AN
Shen, YP
Maillacheruvu, KY
机构
[1] Northeastern Univ, Snell Engn Ctr 400, Dept Civil & Environm Engn, Boston, MA 02115 USA
[2] Bradley Univ, Dept Civil Engn & Construct, Peoria, IL 61625 USA
关键词
aerobic culture; direct current; electrolysis; microbial activity;
D O I
10.1089/109287504323066969
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluates the impact of direct electric currents on the physicochemical and biochemical properties of a mixed aerobic culture. First, changes in dissolved oxygen (DO) concentration, pH, electrical conductivity, temperature, and gas production were evaluated for 2 liters of mixed and aerated tap water samples under 13 and 70 mA constant direct currents. Samples (1.5 liters) of acclimated cultures were then placed in bioelectrochemical reactors and exposed to direct electric (DC) fields of 0, 0.28, 0.57, and 1.14 V/cm for a period of 50 h or higher. Dissolved oxygen concentration, pH, electrical conductivity, and temperature were monitored during exposure to electricity. The results showed that direct electric currents did not cause any significant change in the DO and pH of a completely mixed and aerated system of tap water or activated sludge. COD was monitored to assess if applied DC fields inhibited or stimulated COD removal in an aerobic culture. Low level fields of 0.28 V/cm did not have a significant impact on COD reduction. Exposure to higher level DC fields of 0.57 and 1.14 V/cm increased COD reduction. At the highest voltage applied (1.14 V/cm), the rate of COD reduction decreased after the first 24 h of exposure. There appears to be an optimum range, between 0.28 and 1.14 V/cm, where COD reduction in aerobic cultures can be enhanced. The impact of an applied DC field below 0.28 V/cm may be insignificant. A DC electric field greater than 1.4 V/cm may be harmful.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 17 条
  • [1] Electrokinetic remediation .1. Pilot-scale tests with lead-spiked kaolinite
    Acar, YB
    Alshawabkeh, AN
    [J]. JOURNAL OF GEOTECHNICAL ENGINEERING-ASCE, 1996, 122 (03): : 173 - 185
  • [2] Electrokinetic injection of ammonium and sulfate ions into sand and kaolinite beds
    Acar, YB
    Rabbi, MF
    Ozsu, EE
    [J]. JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1997, 123 (03) : 239 - 249
  • [3] Acar YB, 1996, CHEMTECH, V26, P40
  • [4] BERG H, 1993, BIOELECTROCH BIOENER, V31, P1
  • [5] BERG H, 1993, ELECTRO MAGNETOBIOL, V12, P147, DOI 10.3109/15368379309012869
  • [6] CHANGES IN TRANSCRIPTION IN HL-60 CELLS FOLLOWING EXPOSURE TO ALTERNATING CURRENTS FROM ELECTRIC-FIELDS
    BLANK, M
    SOO, L
    LIN, H
    HENDERSON, AS
    GOODMAN, R
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 28 (1-2): : 301 - 309
  • [7] Buerk D.G., 1993, Biosensors: Theory and Applications
  • [8] Casper M.S., 1978, Hydrogen Manufacture by Electrolysis, Thermal Decomposition and Unusual Techniques
  • [9] Electrokinetic transport of bacteria
    DeFlaun, MF
    Condee, CW
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 1997, 55 (1-3) : 263 - 277
  • [10] ELLIS TG, 1995, THESIS CLEMSON U