The evaluation of two automated soluble fibrin assays for use in the routine hospital laboratory

被引:5
作者
Westerlund, E. [1 ]
Woodhams, B. J. [2 ]
Eintrei, J. [3 ]
Soderblom, L. [3 ]
Antovic, J. P. [3 ]
机构
[1] Karolinska Univ Hosp, Dept Emergency Med, S-17176 Stockholm, Sweden
[2] HaemaCon Ltd, Kent, OH USA
[3] Karolinska Univ Hosp, Karolinska Inst & Clin Chem, Inst Mol Med & Surg, Dept Coagulat, S-17176 Stockholm, Sweden
关键词
Soluble fibrin; DIC; laboratory practice; coagulation; D-Dimer; DEGRADATION-PRODUCTS; D-DIMER; MARKER;
D O I
10.1111/ijlh.12117
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe soluble fibrin monomer (sFM) assay, like the D-dimer (DDi) assay, has the potential to be used both as an aid in the diagnosis of disseminated intravascular coagulation (DIC) and as a thrombotic marker. It differs from DDi in that it is a much earlier produced fragment produced only by thrombin action on fibrinogen, whereas DDi is a much later produced fragment formed by plasmin cleavage of cross-linked fibrin. MethodsIn our study, we compared two commercially available automated sFM assays in the routine hospital setting using samples obtained from the general hospital ward and the emergency room. The results obtained with the two automated assays (Stago LIA sFM assays and the LPIA-Iatro SF assay) were compared with each other and with the results obtained using the routine semiquantitative hemagglutination assay. ResultsThe study showed that both automated assays were comparable with each other. No patient sample previously classified as positive would be missed, but with the higher sensitivity in the automated tests, more samples are positive. ConclusionIn conclusion, we suggest that both automated tests are suitable for routine laboratory use. Both assays had the advantage over the hemagglutination assay in that previously frozen samples could be used, and the assays are easier and quicker to perform. The LIA sFM Stago has slightly better sensitivity but has a tendency to lower specificity than the Iatro SF test.
引用
收藏
页码:666 / 671
页数:6
相关论文
共 7 条
[1]   Use of soluble fibrin antigen instead of D-dimer as fibrin-related marker may enhance the prognostic power of the ISTH overt DIC score [J].
Dempfle, CE ;
Wurst, M ;
Smolinski, M ;
Lorenz, S ;
Osika, A ;
Olenik, D ;
Fiedler, F ;
Borggrefe, M .
THROMBOSIS AND HAEMOSTASIS, 2004, 91 (04) :812-818
[2]   Soluble fibrin monomer degradation products as a potentially useful marker for hypercoagulable states with accelerated fibrinolysis [J].
Ieko, Masahiro ;
Nakabayashi, Toru ;
Tarumi, Takashi ;
Naito, Surniyoshi ;
Yoshida, Mika ;
Kanazawa, Kaori ;
Mizukami, Kazuhiro ;
Koike, Takao .
CLINICA CHIMICA ACTA, 2007, 386 (1-2) :38-45
[3]   Reactivity of soluble fibrin assays with plasmic degradation products of fibrin and in patients receiving fibrinolytic therapy [J].
McCarron, BI ;
Marder, VJ ;
Francis, CW .
THROMBOSIS AND HAEMOSTASIS, 1999, 82 (06) :1722-1729
[4]  
Nakahara K, 2003, THROMB HAEMOSTASIS, V89, P832
[5]   Comparison of diagnostic accuracies in outpatients and hospitalized patients of D-Dimer testing for the evaluation of suspected pulmonary embolism [J].
Schrecengost, JE ;
LeGallo, RD ;
Boyd, JC ;
Moons, KGM ;
Gonias, SL ;
Rose, CE ;
Bruns, DE .
CLINICAL CHEMISTRY, 2003, 49 (09) :1483-1490
[6]   Increased soluble fibrin in plasma of patients with disseminated intravascular coagulation [J].
Wada, H ;
Sase, T ;
Matsumoto, T ;
Kushiya, F ;
Sakakura, M ;
Mori, Y ;
Nishikawa, M ;
Ohnishi, K ;
Nakatani, K ;
Gabazza, EC ;
Shiku, H ;
Nobori, T .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2003, 9 (03) :233-240
[7]   Are fibrin-related markers useful for the diagnosis of thrombosis? [J].
Wada, Hideo ;
Sakuragawa, Nobuo .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2008, 34 (01) :33-38