Frequency sweep rate dependence on the dielectrophoretic response of polystyrene beads and red blood cells

被引:23
作者
Adams, T. N. G. [1 ]
Leonard, K. M. [1 ]
Minerick, A. R. [1 ]
机构
[1] Michigan Technol Univ, Dept Chem Engn, Houghton, MI 49931 USA
基金
美国国家科学基金会;
关键词
FIELD-FLOW-FRACTIONATION; NEGATIVE-DIELECTROPHORESIS; SEPARATION; ACCUMULATION; PARTICLES;
D O I
10.1063/1.4833095
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alternating current (AC) dielectrophoresis (DEP) experiments for biological particles in microdevices are typically done at a fixed frequency. Reconstructing the DEP response curve from static frequency experiments is laborious, but essential to ascertain differences in dielectric properties of biological particles. Our lab explored the concept of sweeping the frequency as a function of time to rapidly determine the DEP response curve from fewer experiments. For the purpose of determining an ideal sweep rate, homogeneous 6.08 mu m polystyrene (PS) beads were used as a model system. Translatability of the sweep rate approach to similar to 7 mu m red blood cells (RBC) was then verified. An Au/Ti quadrapole electrode microfluidic device was used to separately subject particles and cells to 10Vpp AC electric fields at frequencies ranging from 0.010 to 2.0MHz over sweep rates from 0.00080 to 0.17MHz/s. PS beads exhibited negative DEP assembly over the frequencies explored due to Maxwell-Wagner interfacial polarizations. Results demonstrate that frequency sweep rates must be slower than particle polarization timescales to achieve reliable incremental polarizations; sweep rates near 0.00080 MHz/s yielded DEP behaviors very consistent with static frequency DEP responses for both PS beads and RBCs. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:10
相关论文
共 40 条
[1]   Rapid, automated measurement of dielectrophoretic forces using DEP-activated microwells [J].
Broche, Lionel M. ;
Hoettges, Kai F. ;
Ogin, Stephen L. ;
Kass, George E. N. ;
Hughes, Michael P. .
ELECTROPHORESIS, 2011, 32 (17) :2393-2399
[2]   The Diagnosis and Management of Congenital Hemophilia [J].
Carcao, Manuel D. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2012, 38 (07) :727-734
[3]   Rapid quantification of bio-particles based on image visualisation in a dielectrophoretic microfluidic chip [J].
Chung, Cheng-Che ;
Cheng, I-Fang ;
Lin, Chi-Chang ;
Chang, Hsien-Chang .
MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (02) :311-319
[4]   Dielectric cell separation of fine needle aspirates from tumor xenografts [J].
Cristofanilli, Massimo ;
Krishnamurthy, Savitri ;
Das, Chandra M. ;
Reuben, James M. ;
Spohn, William ;
Noshari, Jamileh ;
Becker, Frederick ;
Gascoyne, Peter R. .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (21) :3732-3739
[5]   Unique dielectric properties distinguish stem cells and their differentiated progeny [J].
Flanagan, Lisa A. ;
Lu, Jente ;
Wang, Lisen ;
Marchenko, Steve A. ;
Jeon, Noo Li ;
Lee, Abraham P. ;
Monuki, Edwin S. .
STEM CELLS, 2008, 26 (03) :656-665
[6]   Red blood cell morphology [J].
Ford, J. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 (03) :351-357
[7]   Cellular dielectrophoresis: Applications to the characterization, manipulation, separation and patterning of cells [J].
Gagnon, Zachary R. .
ELECTROPHORESIS, 2011, 32 (18) :2466-2487
[8]   Electrothermal ac electro-osmosis [J].
Gagnon, Zachary R. ;
Chang, Hsueh-Chia .
APPLIED PHYSICS LETTERS, 2009, 94 (02)
[9]   Microfluidic approaches to malaria detection [J].
Gascoyne, P ;
Satayavivad, J ;
Ruchirawat, M .
ACTA TROPICA, 2004, 89 (03) :357-369
[10]   Dielectrophoresis assisted concentration of micro-particles and their rapid quantitation based on optical means [J].
Ghubade, Anil ;
Mandal, Swarnasri ;
Chaudhury, Rahul ;
Singh, Rajeev Kumar ;
Bhattacharya, Shantanu .
BIOMEDICAL MICRODEVICES, 2009, 11 (05) :987-995