Combined thermal and daylight analysis of a typical public rental housing development to fulfil green building guidance in Hong Kong

被引:35
作者
Chen, Xi [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, RERG, Hong Kong, Hong Kong, Peoples R China
关键词
Natural ventilation; Thermal comfort; Daylight; Energy saving; Green building; SIDED NATURAL VENTILATION; RESIDENTIAL BUILDINGS; ENERGY-CONSUMPTION; AIR-FLOW; PERFORMANCE; COMFORT; SIMULATION; ROOMS;
D O I
10.1016/j.enbuild.2015.09.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a combined daylight, airflow network and building energy simulation of a Public Rental Housing (PRH) development in Hong Kong to fulfil the requirement of the local green building guidance. The numerical modelling results are partly validated by on-site measurements during the period with the highest monthly average outdoor temperature. Different ventilation control strategies are simulated to optimize natural ventilation performance. The simulation results show that the full-day ventilation strategy contributes to a lower average and peak indoor temperatures compared to the non-ventilation and night-ventilation scenarios. The indoor operative temperature of a worst-case vacant flat lies under the upper 80% acceptability limits in ASHRAE 55 during 67.5% of the modelled period in July. On the other side, at least 95.6% of the habitable area in the case buildings is predicted to experience a higher average daylight factor of 1% compared with the local green building guidance. Furthermore, the energy saving potential of the combined natural ventilation and daylight strategies is anticipated to be 51.9% for air-conditioning and 8.3% for lighting compared to a baseline building, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:420 / 432
页数:13
相关论文
共 30 条
[1]   Optimising louver location to improve indoor thermal comfort based on natural ventilation [J].
Ahmed, N. A. ;
Wongpanyathaworn, K. .
INTERNATIONAL ENERGY CONGRESS 2012, 2012, 49 :169-178
[2]   Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings [J].
Ai, Z. T. ;
Mak, C. M. ;
Niu, J. L. .
INDOOR AIR, 2013, 23 (05) :417-429
[3]  
[Anonymous], 2012, BEAM PLUS ASS FLOW C
[4]  
[Anonymous], 1986, AIR INFILTRATION CAL
[5]  
ASHRAE Standard, 2004, 552013 ASHRAE ANSI, P1
[6]   Sensitivity analysis of the effect of occupant behaviour on the energy consumption of passive house dwellings [J].
Blight, Thomas S. ;
Coley, David A. .
ENERGY AND BUILDINGS, 2013, 66 :183-192
[7]  
Chartered Institution of Building Services Engineers (CIBSE), 2002, COD FOR LIGHT
[8]  
CIBSE, 1997, APPL MAN AM10 NAT VE
[9]   Overview of pressure coefficient data in building energy simulation and airflow network programs [J].
Costola, D. ;
Blocken, B. ;
Hensen, J. L. M. .
BUILDING AND ENVIRONMENT, 2009, 44 (10) :2027-2036
[10]   PREDICTING SINGLE-SIDED NATURAL VENTILATION RATES IN BUILDINGS [J].
DASCALAKI, E ;
SANTAMOURIS, M ;
HELMIS, AAC ;
ASIMAKOPOULOS, DN ;
PAPADOPOULOS, K ;
SOILEMES, A .
SOLAR ENERGY, 1995, 55 (05) :327-341