How Inaccurate is Weight as a Metric for Patient Size? Comparing Patient Weight to Effective Diameter for Size-Specific Dose Estimation

被引:2
|
作者
Cook, Tessa S. [1 ]
Chadalavada, Seetharam C. [1 ]
Boonn, William W. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
MEDICAL IMAGING 2013: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS | 2013年 / 8674卷
关键词
patient-specific dose monitoring; computed tomography; size-specific dose estimates; patient size metrics; CT;
D O I
10.1117/12.2006132
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the biggest challenges in dose monitoring is customization of CT dose estimates to the patient. Patient size remains a highly significant variable. One metric that has previously been used for patient size is patient weight, though this is often criticized as inaccurate. In this work, we compare patients' weight to their effective diameters obtained from a CT scan of the chest or the abdomen. CT exams of the chest (N= 163) and abdomen/pelvis (N= 168) performed on adult patients in July 2012 were randomly selected for analysis. The effective diameter of the patient for each exam was determined using the central slice of the scan region for each exam using eXposure (TM) (Radimetrics, Inc., Toronto, Canada). In some cases, the same patient had both a chest and abdominopelvic CT, so effective diameters from both regions were analyzed. In this small sample size, there appears to be a linear relationship between patient weight and effective diameter when measured in the mid-chest and mid-abdomen of adult patients. However, for each weight, patient effective diameter can vary by 5 cm from the regression line in both the chest and the abdomen. A 5-cm difference corresponds to a difference of approximately 0.2 in the chest and 0.3 in the abdomen/pelvis for the correction factors recommended for size-specific dose estimation by the AAPM. This preliminary data suggests that weight-based CT protocoling may in fact be appropriate for some adults. However, more work is needed to identify those patients in whom weight-based protocoling is not appropriate.
引用
收藏
页数:6
相关论文
共 48 条
  • [41] Estimation of organ and effective doses of CBCT scans of radiotherapy using size-specific field of view (FOV): a Monte Carlo study
    Abuhaimed, Abdullah
    Mujammami, Huda
    Alenazi, Khaled
    Abanomy, Ahmed
    Alashban, Yazeed
    Martin, Colin J.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 895 - 906
  • [42] Correlations Between Body Weight and Size- Specific Dose Estimate on Thoracic Computed Tomography Examination
    Wati, A. L.
    Anam, C.
    Nitasari, A.
    Syarifudin
    Dougherty, G.
    ATOM INDONESIA, 2022, 48 (01) : 61 - 65
  • [43] Development of a novel automated algorithm for patient dosimetry in computed tomography: a step towards the facilitation of size-specific dose estimates and organs dosimetry estimations in a busy clinical workflow
    Sekkat, Hamza
    Khallouqi, Abdellah
    Madkouri, Youssef
    El Atifi, Wiam
    Rhouch, Imane
    El Rhazouani, Omar
    Tahiri, Zakaria
    Talbi, Mohammed
    Halimi, Abdellah
    PHYSICA SCRIPTA, 2024, 99 (12)
  • [44] Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients
    Sookpeng, Supawitoo
    Martin, Colin J.
    Rattanarungruangchai, Natch
    Lopez-Gonzalez, M. Rosario
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (04) : 710 - 718
  • [45] Using the Microsoft Kinect for Patient Size Estimation and Radiation Dose Normalization: Proof of Concept and Initial Validation
    Cook, Tessa S.
    Couch, Gregory
    Couch, Timothy J.
    Kim, Woojin
    Boonn, William W.
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 657 - 662
  • [46] Patient-specific Effective Dose Estimation from Dose-Length Product in Lung Computed Tomography Using Monte Carlo Simulation
    Fallahmohammadi, Gholamreza
    Nodeh, Zeinab Kordzini
    Mahdavi, Mohammad
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (04):
  • [47] Characterizing pediatric head patient size in Moroccan population: Establishing age-dependent relationships for accurate CT dose estimation
    Sekkat, H.
    Elmansouri, K.
    Khallouqi, A.
    Halimi, A.
    El Rhazouani, O.
    Tahiri, Z.
    Talbi, M.
    El Mansouri, M.
    RADIOPROTECTION, 2024, 59 (03) : 203 - 210
  • [48] Size-specific dose estimates of adult, chest computed tomography examinations: Comparison of Chinese and updated 2017 American College of Radiology diagnostic reference levels based on the water-equivalent diameter
    Hu, Xiaoyan
    Gou, Jie
    Lin, Wei
    Zou, Chunhua
    Li, Wenbo
    PLOS ONE, 2021, 16 (09):