How Inaccurate is Weight as a Metric for Patient Size? Comparing Patient Weight to Effective Diameter for Size-Specific Dose Estimation

被引:2
|
作者
Cook, Tessa S. [1 ]
Chadalavada, Seetharam C. [1 ]
Boonn, William W. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
MEDICAL IMAGING 2013: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS | 2013年 / 8674卷
关键词
patient-specific dose monitoring; computed tomography; size-specific dose estimates; patient size metrics; CT;
D O I
10.1117/12.2006132
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the biggest challenges in dose monitoring is customization of CT dose estimates to the patient. Patient size remains a highly significant variable. One metric that has previously been used for patient size is patient weight, though this is often criticized as inaccurate. In this work, we compare patients' weight to their effective diameters obtained from a CT scan of the chest or the abdomen. CT exams of the chest (N= 163) and abdomen/pelvis (N= 168) performed on adult patients in July 2012 were randomly selected for analysis. The effective diameter of the patient for each exam was determined using the central slice of the scan region for each exam using eXposure (TM) (Radimetrics, Inc., Toronto, Canada). In some cases, the same patient had both a chest and abdominopelvic CT, so effective diameters from both regions were analyzed. In this small sample size, there appears to be a linear relationship between patient weight and effective diameter when measured in the mid-chest and mid-abdomen of adult patients. However, for each weight, patient effective diameter can vary by 5 cm from the regression line in both the chest and the abdomen. A 5-cm difference corresponds to a difference of approximately 0.2 in the chest and 0.3 in the abdomen/pelvis for the correction factors recommended for size-specific dose estimation by the AAPM. This preliminary data suggests that weight-based CT protocoling may in fact be appropriate for some adults. However, more work is needed to identify those patients in whom weight-based protocoling is not appropriate.
引用
收藏
页数:6
相关论文
共 48 条
  • [31] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548
  • [32] Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent Diameter
    Leng, Shuai
    Shiung, Maria
    Duan, Xinhui
    Yu, Lifeng
    Zhang, Yi
    McCollough, Cynthia H.
    RADIOLOGY, 2015, 276 (01) : 184 - 190
  • [33] Estimation of radiation dose associated with bone SPECT/CT and establishing local diagnostic reference levels using size-specific dose estimate
    Alrehily, Faisal
    Alshamrani, Abdullah F.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (01)
  • [34] An Analytic Method for Calculating Scanner-, Kilovoltage Peak-, and Patient Size-Specific Hounsfield Unit Scale Thresholds for Agatston Score
    Peng, Boyu
    Jambawalikar, Sachin
    Einstein, Andrew J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (03) : 423 - 433
  • [35] CT-guided liver biopsy: correlation of procedure time and radiation dose with patient size, weight, and lesion volume and depth
    Li, Jianhai
    Udayasankar, Unni K.
    Carew, John
    Small, William C.
    CLINICAL IMAGING, 2010, 34 (04) : 263 - 268
  • [36] Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Yu, Lifeng
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2012, 39 (11) : 6764 - 6771
  • [37] Machine learning-based estimation of patient body weight from radiation dose metrics in computed tomography
    Ichikawa, Hajime
    Ichikawa, Shota
    Sawane, Yasuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [38] A SIMPLE METHOD FOR CALIBRATING PIXEL VALUES OF THE CT LOCALIZER RADIOGRAPH FOR CALCULATING WATER-EQUIVALENT DIAMETER AND SIZE-SPECIFIC DOSE ESTIMATE
    Anam, Choirul
    Fujibuchi, Toshioh
    Toyoda, Takatoshi
    Sato, Naoki
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (02) : 158 - 168
  • [39] Establishing how patient size and degree of miscentring affect CTDIvol, using patient data from a dose tracking system
    Cournane, Sean
    Brunell, Eimear
    Rowan, Michael
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1099)
  • [40] Size specific dose estimates for adult patients in CT of the Kidney, Ureters, and Bladder (KUB) based on effective diameter and water equivalent diameter
    Alenazi, Khaled
    Alahmad, Haitham
    Albeshan, Salman
    Almeshari, Meshari
    Abanomy, Ahmad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229