How Inaccurate is Weight as a Metric for Patient Size? Comparing Patient Weight to Effective Diameter for Size-Specific Dose Estimation

被引:2
|
作者
Cook, Tessa S. [1 ]
Chadalavada, Seetharam C. [1 ]
Boonn, William W. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
MEDICAL IMAGING 2013: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS | 2013年 / 8674卷
关键词
patient-specific dose monitoring; computed tomography; size-specific dose estimates; patient size metrics; CT;
D O I
10.1117/12.2006132
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the biggest challenges in dose monitoring is customization of CT dose estimates to the patient. Patient size remains a highly significant variable. One metric that has previously been used for patient size is patient weight, though this is often criticized as inaccurate. In this work, we compare patients' weight to their effective diameters obtained from a CT scan of the chest or the abdomen. CT exams of the chest (N= 163) and abdomen/pelvis (N= 168) performed on adult patients in July 2012 were randomly selected for analysis. The effective diameter of the patient for each exam was determined using the central slice of the scan region for each exam using eXposure (TM) (Radimetrics, Inc., Toronto, Canada). In some cases, the same patient had both a chest and abdominopelvic CT, so effective diameters from both regions were analyzed. In this small sample size, there appears to be a linear relationship between patient weight and effective diameter when measured in the mid-chest and mid-abdomen of adult patients. However, for each weight, patient effective diameter can vary by 5 cm from the regression line in both the chest and the abdomen. A 5-cm difference corresponds to a difference of approximately 0.2 in the chest and 0.3 in the abdomen/pelvis for the correction factors recommended for size-specific dose estimation by the AAPM. This preliminary data suggests that weight-based CT protocoling may in fact be appropriate for some adults. However, more work is needed to identify those patients in whom weight-based protocoling is not appropriate.
引用
收藏
页数:6
相关论文
共 48 条
  • [21] Estimating Patient Dose from X-ray Tube Output Metrics: Automated Measurement of Patient Size from CT Images Enables Large-scale Size-specific Dose Estimates
    Ikuta, Ichiro
    Warden, Graham I.
    Andriole, Katherine P.
    Khorasani, Ramin
    Sodickson, Aaron
    RADIOLOGY, 2014, 270 (02) : 472 - 480
  • [22] Patient size matters: Effect of tube current modulation on size-specific dose estimates (SSDE) and image quality in low-dose lung cancer screening CT
    Barreto, Izabella
    Verma, Nupur
    Quails, Nathan
    Olguin, Catherine
    Correa, Nathalie
    Mohammed, Tan-Lucien
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (04): : 87 - 94
  • [23] Size-Specific Dose Estimates of Radiation Based on Body Weight and Body Mass Index for Chest and Abdomen-Pelvic CTs
    Xu, Jian
    Wang, Xiangquan
    Yang, Panfeng
    Luo, Kuangnan
    He, Xiaolong
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [24] Automated Estimation of Abdominal Effective Diameter for Body Size Normalization of CT Dose
    Cheng, Phillip M.
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (03) : 406 - 411
  • [25] Automated Estimation of Abdominal Effective Diameter for Body Size Normalization of CT Dose
    Phillip M. Cheng
    Journal of Digital Imaging, 2013, 26 : 406 - 411
  • [26] Size-specific dose estimates calculated using patient size measurements from scanned projection radiograph in high-resolution chest computed tomography
    Brindhaban, Ajit
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 85 - 92
  • [27] Comparison between Deff and Dw approaches for estimation of size-specific dose in paediatric CT imaging
    Abdulkadir, Muhammad Kabir
    Shuaib, Ibrahim Lutfi
    Nasirudin, R. A.
    Samsudin, Ahmad Hadif Zaidin
    Osman, Noor Diyana
    RADIATION PHYSICS AND CHEMISTRY, 2022, 198
  • [28] Considerations on the practical application of the size-specific dose estimation (SSDE) method of AAPM Report 204
    Noferini L.
    Fulcheri C.
    Taddeucci A.
    Bartolini M.
    Gori C.
    Radiological Physics and Technology, 2014, 7 (2) : 296 - 302
  • [29] DOSE ESTIMATING APPLICATION SOFTWARE MODIFICATION: ADDITIONAL FUNCTION OF A SIZE-SPECIFIC EFFECTIVE DOSE CALCULATOR AND AUTO EXPOSURE CONTROL
    Kobayashi, Masanao
    Asada, Yasuki
    Matsubara, Kosuke
    Suzuki, Shouichi
    Matsunaga, Yuta
    Haba, Tomonobu
    Kawaguchi, Ai
    Daioku, Tomihiko
    Toyama, Hiroshi
    Kato, Ryoichi
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (04) : 535 - 540
  • [30] Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs
    Kazuki Kuriyama
    Kosuke Matsubara
    Shu Hisahara
    Yukie Nagata
    Rumiko Nosaka
    Rika Goto
    Nobutaka Yanano
    Kanichiro Shimizu
    Tomokazu Shoji
    Physical and Engineering Sciences in Medicine, 2020, 43 : 665 - 672