Effective Dose Calculations in Conventional Diagnostic X-Ray Examinations for Patients in Major Sudanese Hospitals

被引:0
作者
Suliman, I. I. [1 ]
Habbani, F. I. [2 ]
机构
[1] Sudan Atom Energy Commiss, Radiat Safety Inst, Gamma St,POB 3001, Khartoum, Sudan
[2] Univ Khartoum, Fac Sci, Dept Phys, Khartoum, Sudan
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 | 2007年 / 14卷
关键词
effective dose; diagnostic radiology; energy imparted;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work was to compare two methods used for effective dose (ED) calculation in conventional diagnostic x-ray examinations and to analyze effective dose distributions among radiological departments under study. The study was performed in four major hospitals in Khartoum area, Sudan, covering eight x-ray units and a sample of 325 patients. Two approaches were used for effective dose calculation: In the first approach, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations. The ED values were then calculated from the obtained ESD values using NRPB-SR262 Monte Carlo data and XDOSE software. In the second approach, the energy imparted to patients in the same x-ray examinations was computed using values for entrance skin exposure, half- value layer and exposure area. Effective doses were then calculated from energy imparted using ED conversion factors proposed by other authors. The results of ED values calculated using the two approaches were in good agreement between themselves and with data reported in the literature. The mean ED values calculated using the Monte Carlo data and XDOSE software were found to be 29.9, 44.1, 8.91, 232.5, 224.5 and 93.6 mu Sv for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively. Almost all ED values were below the corresponding DRLs established elsewhere, except for chest PA examination which exhibited comparable mean ED values. The study is expected to increase the awareness among the medical professionals and members of the public on the status of radiological protection in Sudan.
引用
收藏
页码:2087 / +
页数:3
相关论文
共 46 条
  • [21] Use of effective dose to assess x-ray protective clothing
    Eder, Heinrich
    Schlattl, Helmut
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : R140 - R151
  • [22] Constancy check of beam quality in conventional diagnostic X-ray equipment
    Costa, Alessandro M.
    Badin, Romulo S.
    Leite, Marina S.
    Caldas, Linda V. E.
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (10) : 1403 - 1405
  • [23] Definitions and outlook targeting x-ray exposure of patients in diagnostic imaging
    Regulla, Dieter F.
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [24] Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran
    Gholami, M.
    Maziar, A.
    Khosravi, H. R.
    Ebrahimzadeh, F.
    Mayahi, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2015, 13 (01): : 85 - 90
  • [25] Transition from dose times area to effective dose of radiation in x-ray examination
    Voronin K.V.
    [J]. Biomedical Engineering, 1998, 32 (3) : 134 - 136
  • [26] Effective Dose Display System in Gastric Cancer X-ray Screening
    Yamamoto, Kenyu
    Fujiwara, Naoko
    Kiyama, Masahiko
    Takeda, Yoshihiro
    Kuwano, Tadao
    Katsuda, Toshizo
    Azuma, Masami
    Ito, Toshinori
    [J]. JOURNAL OF MEDICAL PHYSICS, 2019, 44 (01) : 35 - 38
  • [27] Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures
    Golikov, Vladislav
    Druzhinina, Polina
    [J]. MEDICAL PHYSICS, 2020, : 5366 - 5372
  • [28] Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures
    Golikov, Vladislav
    Druzhinina, Polina
    [J]. MEDICAL PHYSICS, 2020, 47 (10) : 5366 - 5372
  • [29] Comparison of six phantoms for entrance skin dose evaluation in 11 standard X-ray examinations
    Compagnone, Gaetano
    Pagan, Laura
    Bergamini, Carlo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (01): : 101 - 113
  • [30] Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
    Hambali, Ahmad Shariff
    Ng, Kwan-Hoong
    Abdullah, Basri Johan Jeet
    Wang, Hwee-Beng
    Jamal, Noriah
    Spelic, David C.
    Suleiman, Orhan H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2009, 133 (01) : 25 - 34