Differences between motion capture and video analysis systems in calculating knee angles in elite-standard race walking

被引:21
作者
Hanley, Brian [1 ]
Tucker, Catherine B. [1 ]
Bissas, Athanassios [1 ]
机构
[1] Leeds Beckett Univ, Carnegie Sch Sport, Headingley Campus, Leeds, W Yorkshire, England
关键词
Gait; joint motion; optoelectronics; track and field; videography; KINEMATIC CHARACTERISTICS; VARIABILITY; MARKER; SPORTS; MENS; HIP;
D O I
10.1080/02640414.2017.1372928
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Race walking is an event where the knee must be straightened from first contact with the ground until midstance. The aim of this study was to compare knee angle measurements between 2D videography and 3D optoelectronic systems. Passive retroreflective markers were placed on the right leg of 12 race walkers and 3D marker coordinate data captured (250Hz), with 2D video data (100Hz) recorded simultaneously. Knee angle data were first derived based on the markers' coordinates, and separately by using a 3D model that also incorporated thigh and shank clusters; the video data were analysed using both automatic tracking and manual digitising, creating four conditions overall. Differences were calculated between conditions for stance (using root mean square values), and at discrete events. There were few differences between systems, although the 3D model produced larger angles at midstance than using automatic tracking and marker coordinates (by 3 - 6 degrees, P<0.05). These differences might have occurred because of how the 3D model locates the hip joint, and because of the addition of marker clusters. 2D videography gave similar results to the 3D model when using manual digitising, as it allowed for errors caused by skin movement to be corrected.
引用
收藏
页码:1250 / 1255
页数:6
相关论文
共 31 条
[1]   Comparison of inverse dynamics calculated by two- and three-dimensional models during walking [J].
Alkjaer, T ;
Simonsen, EB ;
Dyhre-Poulsen, F .
GAIT & POSTURE, 2001, 13 (02) :73-77
[2]  
Bahamonde RE., 2006, Proceedings of the XXIV International Symposium on Biomechanics in Sports, V24, P650
[3]   Movement variability cannot be determined reliably from no-marker conditions [J].
Bartlett, Roger ;
Bussey, Melanie ;
Flyger, Nick .
JOURNAL OF BIOMECHANICS, 2006, 39 (16) :3076-3079
[4]   A COMPARISON OF THE ACCURACY OF SEVERAL HIP CENTER LOCATION PREDICTION METHODS [J].
BELL, AL ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (06) :617-621
[5]   Can coordination variability identify performance factors and skill level in competitive sport? The case of race walking [J].
Cazzola, Dario ;
Pavei, Gaspare ;
Preatoni, Ezio .
JOURNAL OF SPORT AND HEALTH SCIENCE, 2016, 5 (01) :35-43
[6]  
Cohen J., 1988, STAT POWER ANAL BEHA, DOI [10.4324/9780203771587, DOI 10.4324/9780203771587]
[7]   In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: Preliminary results [J].
Cutti, AG ;
Cappello, A ;
Davalli, A .
CLINICAL BIOMECHANICS, 2006, 21 :S13-S19
[8]   Application of functional principal component analysis in race walking: An emerging methodology [J].
Dona, Giulia ;
Preatoni, Ezio ;
Cobelli, Claudio ;
Rodano, Renato ;
Harrison, Andrew J. .
SPORTS BIOMECHANICS, 2009, 8 (04) :284-301
[9]  
Field A., 2013, Discovering statistics using IBM SPSS statistics, DOI DOI 10.1016/B978-012691360-6/50012-4
[10]   The use of the greater trochanter marker in the thigh segment model: Implications for hip and knee frontal and transverse plane motion [J].
Graci, Valentina ;
Salsich, Gretchen B. .
JOURNAL OF SPORT AND HEALTH SCIENCE, 2016, 5 (01) :95-100