Miliary tuberculosis presenting as infection of a pacemaker pulse-generator pocket

被引:3
|
作者
Doherty, JG [1 ]
Rankin, R [1 ]
Kerr, F [1 ]
机构
[1] RAIGMORE HOSP NHS TRUST,DEPT HISTOPATHOL,DEPT CARDIOL,INVERNESS IV2 3UJ,SCOTLAND
关键词
tuberculosis; miliary; pacemaker; artificial;
D O I
10.1177/003693309604100108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A seventy year old woman had a permanent VVI pacemaker inserted in 1983 for complete heart block and presented ten years later with purulent discharge from the generator pocket. During a prolonged pyrexial illness, she developed renal and respiratory failure and her illness was complicated by recurrent ventricular fibrillation. The patient died on her 31st hospital day. Subsequent histological and microbiological investigation revealed widespread miliary tuberculosis which included involvement of myocardial tissue, great vessels and the pacemaker pocket. To our knowledge, this is the first reported occurrence of miliary tuberculosis involving a permanent pacemaker system. Furthermore, the granulomatous myocarditis which occurred as part of the miliary picture is a rare occurrence and possibly explains the recurrent ventricular fibrillation.
引用
收藏
页码:20 / 21
页数:2
相关论文
共 50 条
  • [1] CONSERVATIVE MANAGEMENT OF INFECTED PACEMAKER PULSE-GENERATOR
    KUMAZAKI, T
    SAKAKIBARA, O
    SUZUKI, Y
    MATSUMOTO, K
    EMINA, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1973, 37 (01): : 29 - 30
  • [2] PULSE-GENERATOR EXTRUSION USE OF PACEMAKER SUPPORT
    ALI, N
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 219 (02): : 216 - &
  • [3] PACEMAKER PRACTICE - INDICATIONS FOR PULSE-GENERATOR REPLACEMENT
    LANGBERG, J
    MCMANUS, C
    HU, C
    FLETCHER, RD
    GERTZ, EW
    CIRCULATION, 1985, 72 (04) : 175 - 175
  • [4] EXTRUSION OF PACEMAKER PULSE-GENERATOR DUE TO DESIGN DEFECT
    COHN, JD
    THORSON, RF
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1973, 65 (02): : 323 - 326
  • [5] DEVICES EXTERNAL PULSE-GENERATOR - A RELIABLE TEMPORARY PACEMAKER
    INOUE, D
    OCHIAI, M
    KATSUME, H
    IJICHI, H
    CLINICAL CARDIOLOGY, 1987, 10 (12) : 815 - 817
  • [6] PACEMAKER SOUND PERSISTENCE FOLLOWING PULSE-GENERATOR REPLACEMENT
    BALTAZAR, RF
    MOWER, MM
    CLINICAL RESEARCH, 1976, 24 (03): : A207 - A207
  • [7] A SUBPECTORAL POCKET IN THE MANAGEMENT OF A PATIENT WITH IMPENDING EXTRUSION OF A PULSE-GENERATOR
    FAYMAN, MS
    CHAIT, LA
    ORAK, F
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 78 (02) : 182 - 185
  • [8] A CASE OF PACEMAKER LEAD FRACTURE DUE TO DISPLACEMENT OF PULSE-GENERATOR
    YOSHIMURA, F
    HAYASHI, R
    FUJII, N
    YAMADA, M
    ANZAI, N
    JAPANESE JOURNAL OF THORACIC SURGERY, 1980, 33 (05): : 384 - 386
  • [9] TECHNICAL ASPECTS OF A RATE RESPONSIVE PACEMAKER - THE TX PULSE-GENERATOR
    CANDELON, B
    WITTKAMPF, F
    DIAZ, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A109 - A109
  • [10] PULSE-GENERATOR
    RAKHUBOVSKII, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1977, 20 (03) : 730 - 731