Effects of nuclear fusion produced neutrons on silicon semiconductor plasma X-ray detectors

被引:12
|
作者
Kohagura, J
Cho, T
Hirata, M
Numakura, T
Minami, R
Watanabe, H
Sasuga, T
Nishizawa, Y
Yoshida, A
Nagashima, S
Tamano, T
Yatsu, K
Miyoshi, S
Hirano, K
Maezawa, H
机构
[1] Univ Tsukuba, Plasma Res Ctr, Tsukuba, Ibaraki 3058577, Japan
[2] High Energy Accelerator Res Org, Ibaraki, Japan
关键词
semiconductor detector; plasma diagnostics; neutron irradiation;
D O I
10.1016/S0168-9002(01)02020-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The effects of nuclear fusion produced neutrons on the X-ray energy responses of semiconductor detectors are characterized. The degradation of the response of position-sensitive X-ray tomography detectors in the Joint European Torus (JET) tokamak is found after neutron exposure produced by deuterium-deuterium and deuterium-tritium plasma fusion experiments. For the purpose of further detailed characterization of the neutron degradation effects, an azimuthally varying-field (AVF) cyclotron accelerator is employed using well-calibrated neutron fluence. These neutron effects on the detector responses are characterized using synchrotron radiation from a 2.5 GeV positron storage ring at the Photon Factory (KEK). The effects of neutrons on X-ray sensitive semiconductor depletion thicknesses are also investigated using an impedance analyser. Novel findings of (i) the dependence of the response degradation on X-ray energies as well as (ii) the recovery of the degraded detector response due to the detector bias application are found and interpreted by systematically combined methods using a synchrotron facility, a cyclotron facility, a fusion plasma device, material analysis methods along with our recent theory on semiconductor X-ray responses. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 219
页数:5
相关论文
共 50 条
  • [31] UV and soft x-ray emission from gaseous and solid targets employing SiC detectors
    Torrisi, Alfio
    Wachulak, Przemyslaw
    Torrisi, Lorenzo
    PLASMA SCIENCE & TECHNOLOGY, 2021, 23 (05)
  • [32] Soft x-ray laser interferometry study of dense plasma jet collimation
    Grava, J.
    Ryan, D. P.
    Purvis, M. A.
    Filevich, J.
    Shlyaptsev, V. N.
    Rocca, J. J.
    Moon, S. J.
    Dunn, J.
    2010 23RD ANNUAL MEETING OF THE IEEE PHOTONICS SOCIETY, 2010, : 337 - +
  • [33] Spectral analysis of K-shell X-ray emission of magnesium plasma produced by ultrashort high-intensity laser pulse irradiation
    V ARORA
    U CHAKRAVARTY
    MANORANJAN P SINGH
    J A CHAKERA
    P A NAIK
    P D GUPTA
    Pramana, 2014, 82 : 365 - 371
  • [34] Spectral analysis of K-shell X-ray emission of magnesium plasma produced by ultrashort high-intensity laser pulse irradiation
    Arora, V.
    Chakravarty, U.
    Singh, Manoranjan P.
    Chakera, J. A.
    Naik, P. A.
    Gupta, P. D.
    PRAMANA-JOURNAL OF PHYSICS, 2014, 82 (02): : 365 - 371
  • [35] The Si/CdTe semiconductor camera of the ASTRO-H Hard X-ray Imager (HXI)
    Sato, Goro
    Hagino, Kouichi
    Watanabe, Shin
    Genba, Kei
    Harayama, Atsushi
    Kanematsu, Hironori
    Kataoka, Jun
    Katsuragawa, Miho
    Kawaharada, Madoka
    Kobayashi, Shogo
    Kokubun, Motohide
    Kuroda, Yoshikatsu
    Makishima, Kazuo
    Masukawa, Kazunori
    Mimura, Taketo
    Miyake, Katsuma
    Murakami, Hiroaki
    Nakano, Toshio
    Nakazawa, Kazuhiro
    Noda, Hirofumi
    Odaka, Hirokazu
    Onishi, Mitsunobu
    Saito, Shinya
    Sato, Rie
    Sato, Tamotsu
    Tajima, Hiroyasu
    Takahashi, Hiromitsu
    Takahashi, Tadayuki
    Takeda, Shin'ichiro
    Yuasa, Takayuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 235 - 241
  • [36] Opacity of Krypton X-ray lines in high-temperature plasma implosion
    Zhen, Zhiqiang
    He, Jian
    MODERN PHYSICS LETTERS B, 2019, 33 (33):
  • [37] Laser ablation and plasma interferometry with a table top soft x-ray laser
    Rocca, JJ
    Filevich, J
    Marconi, MC
    Ozols, A
    Kanizay, K
    Benware, BR
    Chilla, JLA
    Artioukov, IA
    Kasjanov, YS
    Kondratenko, VV
    Vinogradov, AV
    HIGH-POWER LASER ABLATION III, 2000, 4065 : 173 - 184
  • [38] Diagnostics of plasma based on K, L and M x-ray line positions
    Slabkowska, Katarzyna
    Szymanska, Ewa
    Starosta, Joanna
    Polasik, Marek
    Pereira, Nino R.
    Rzadkiewicz, Jacek
    Kubkowska, Monika
    Czarnecka, Agata
    PHYSICA SCRIPTA, 2014, T161
  • [39] X-ray absorption and VUV spectroscopic studies of silica glasses irradiated in a nuclear reactor
    Yoshida, T
    Tanabe, T
    Yoshida, H
    Ii, T
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2001, 119 (2-3) : 221 - 227
  • [40] Spatially resolved high resolution x-ray spectroscopy for magnetically confined fusion plasmas (invited)
    Ince-Cushman, A.
    Rice, J. E.
    Bitter, M.
    Reinke, M. L.
    Hill, K. W.
    Gu, M. F.
    Eikenberry, E.
    Broennimann, Ch.
    Scott, S.
    Podpaly, Y.
    Lee, S. G.
    Marmar, E. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)