Effects of nuclear fusion produced neutrons on silicon semiconductor plasma X-ray detectors

被引:12
|
作者
Kohagura, J
Cho, T
Hirata, M
Numakura, T
Minami, R
Watanabe, H
Sasuga, T
Nishizawa, Y
Yoshida, A
Nagashima, S
Tamano, T
Yatsu, K
Miyoshi, S
Hirano, K
Maezawa, H
机构
[1] Univ Tsukuba, Plasma Res Ctr, Tsukuba, Ibaraki 3058577, Japan
[2] High Energy Accelerator Res Org, Ibaraki, Japan
关键词
semiconductor detector; plasma diagnostics; neutron irradiation;
D O I
10.1016/S0168-9002(01)02020-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The effects of nuclear fusion produced neutrons on the X-ray energy responses of semiconductor detectors are characterized. The degradation of the response of position-sensitive X-ray tomography detectors in the Joint European Torus (JET) tokamak is found after neutron exposure produced by deuterium-deuterium and deuterium-tritium plasma fusion experiments. For the purpose of further detailed characterization of the neutron degradation effects, an azimuthally varying-field (AVF) cyclotron accelerator is employed using well-calibrated neutron fluence. These neutron effects on the detector responses are characterized using synchrotron radiation from a 2.5 GeV positron storage ring at the Photon Factory (KEK). The effects of neutrons on X-ray sensitive semiconductor depletion thicknesses are also investigated using an impedance analyser. Novel findings of (i) the dependence of the response degradation on X-ray energies as well as (ii) the recovery of the degraded detector response due to the detector bias application are found and interpreted by systematically combined methods using a synchrotron facility, a cyclotron facility, a fusion plasma device, material analysis methods along with our recent theory on semiconductor X-ray responses. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 219
页数:5
相关论文
共 50 条
  • [21] Soft X-ray oscillations from AT Mic: Flare plasma diagnostics
    Stepanov, A. V.
    Tsap, Yu. T.
    Kopylova, Yu. G.
    ASTRONOMY LETTERS-A JOURNAL OF ASTRONOMY AND SPACE ASTROPHYSICS, 2006, 32 (08): : 569 - 573
  • [22] Plasma Diagnostics with a table-top soft x-ray laser
    Rocca, JJ
    Marconi, MC
    Filevich, J
    Kanizay, K
    Moreno, CH
    Chilla, JLA
    Berglund, RJ
    Shlyaptsev, VN
    Unspenskii, YA
    Vinogradov, AV
    Pershin, YP
    HIGH-POWER LASERS IN ENERGY ENGINEERING, 2000, 3886 : 266 - 277
  • [23] K X-ray line energies as diagnostics of warm dense plasma
    Slabkowska, K.
    Szymanska, E.
    Pereira, N. R.
    Syrocki, L.
    Rzadkiewicz, J.
    Polasik, M.
    HIGH ENERGY DENSITY PHYSICS, 2015, 14 : 30 - 32
  • [24] Soft X-ray oscillations from AT Mic: Flare plasma diagnostics
    A. V. Stepanov
    Yu. T. Tsap
    Yu. G. Kopylova
    Astronomy Letters, 2006, 32 : 569 - 573
  • [25] The K X-ray line structures for a warm dense copper plasma
    Slabkowska, K.
    Szymanska, E.
    Syrocki, L.
    Rzadkiewicz, J.
    Polasik, M.
    HIGH ENERGY DENSITY PHYSICS, 2015, 15 : 8 - 11
  • [26] Precision Measurements of X-Ray Spectra for the Diagnosis of Laboratory Astrophysical Plasma
    Ryazantsev, S. N.
    Skobelev, I. Yu.
    Kuznetsov, A. P.
    Kulikov, R. K.
    Pikuz, S. A.
    ASTRONOMY REPORTS, 2023, 67 (01) : 86 - 92
  • [27] X-ray tomography systems for observations of electron cyclotron heated plasmas using novel position-sensitive - X-ray semiconductor-detector arrays
    Numakura, T.
    Cho, T.
    Kohagura, J.
    Hirata, M.
    Tomii, Y.
    Kiminami, S.
    Shimizu, K.
    Morimoto, N.
    Takahashi, Y.
    Imai, T.
    Miyoshi, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2) : 53 - 56
  • [28] Precision Measurements of X-Ray Spectra for the Diagnosis of Laboratory Astrophysical Plasma
    S. N. Ryazantsev
    I. Yu. Skobelev
    A. P. Kuznetsov
    R. K. Kulikov
    S. A. Pikuz
    Astronomy Reports, 2023, 67 : 86 - 92
  • [29] Design of an elliptical crystal spectrometer for diagnosing pulsed plasma x-ray
    Zhong, XX
    Xiong, XC
    Xiao, SL
    Chen, Y
    Qian, JY
    Gao, J
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION VII, 2004, 5524 : 330 - 336
  • [30] Measurement of high x-ray doses from PF1000 plasma focus using Si p-i-n detectors
    Ryc, L
    Bienkowska, B
    Borowrecki, M
    Ivanova-Stanik, I
    Kaczmarczyk, J
    Paduch, M
    Scholz, M
    Tomaszewski, K
    Krása, J
    Kravárik, J
    Kubes, P
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2004, 54 : 326 - 333