Correlation of retention of lanthanide and actinide complexes with stability constants and their speciation

被引:16
作者
Datta, A. [1 ]
Sivaraman, N. [1 ]
Viswanathan, K. S. [1 ]
Ghosh, Suddhasattwa [1 ]
Srinivasan, T. G. [1 ]
Rao, P. R. Vasudeva [1 ]
机构
[1] Indira Gandhi Ctr Atom Res, Chem Grp, Kalpakkam 603102, Tamil Nadu, India
关键词
Stability constant; HPLC; Lanthanides; Actinides; Speciation; alpha-HIBA; ION-EXCHANGE CHROMATOGRAPHY; METAL-IONS; URANIUM; SEPARATION; THORIUM; ACID; EQUILIBRIA; FISSIONS; CATIONS; MODELS;
D O I
10.1524/ract.2013.2005
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The present study describes a correlation that is developed from retention of lanthanide and actinide complexes with the stability constant. In these studies, an ion-pairing reagent, camphor-10-sulphonic acid (CSA) was used as the modifier and organic acids such as alpha-hydroxy isobutyric acid (alpha-HIBA), mandelic acid, lactic acid and tartaric acid were used as complexing reagent for elution. From these studies, a correlation has been established between capacity factor of a metal ion, concentration of ion-pairing reagent and complexing agent with the stability constant of metal complex. Based on these studies, it has been shown that the stability constant of lanthanide and actinide complexes can be estimated using a single lanthanide calibrant. Validation of the method was carried out with the complexing agents such as alpha-HIBA and lactic acid. It was also demonstrated that data from a single chromatogram can be used for estimation of stability constant at various ionic strengths. These studies also demonstrated that the method can be applied for estimation of stability constant of actinides with a ligand whose value is not reported yet, e.g., ligands of importance in the lanthanide actinide separations, chelation therapy etc. The chromatographic separation method is fast and the estimation of stability constant can be done in a very short time, which is a significant advantage especially in dealing with radioactive elements. The stability constant data was used to derive speciation data of plutonium in different oxidation states as well as that of americium with alpha-HIBA. The elution behavior of actinides such as Pu and Am from reversed phase chromatographic technique could be explained based on these studies.
引用
收藏
页码:81 / 92
页数:12
相关论文
共 35 条
[21]   Retention models for the ion chromatographic separations of metals in the presence of complexing agents [J].
Janos, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (02) :129-138
[22]   DYNAMIC ION-EXCHANGE CHROMATOGRAPHY FOR DETERMINATION OF NUMBER OF FISSIONS IN THORIUM URANIUM-DIOXIDE FUELS [J].
KNIGHT, CH ;
CASSIDY, RM ;
RECOSKIE, BM ;
GREEN, LW .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :474-478
[23]   Determination of stability constants of Cu(II), Fe(III) and Pb(II) chelates with N,N,N',N'-ethylenediamine tetrakis (methylenephosphonic acid) by reversed-phase ion-pair chromatography [J].
Li, CY ;
Gao, LZ ;
Zhao, GH ;
Kang, JW ;
He, HH .
CHROMATOGRAPHIA, 1997, 46 (9-10) :489-494
[24]   MEASUREMENT OF STABILITY-CONSTANTS FOR COMPLEXES OF DIVALENT-CATIONS WITH TARTARIC ACID BY ION CHROMATOGRAPHY [J].
LIN, FHJ ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2) :185-195
[25]   DETERMINATION OF TRACE LANTHANIDE IMPURITIES IN NUCLEAR GRADE URANIUM BY COUPLED-COLUMN LIQUID-CHROMATOGRAPHY [J].
LUCY, CA ;
GURELI, L ;
ELCHUK, S .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :3320-3325
[26]  
MONK CB, 1961, ELECTROLYTIC DISSOCI
[27]   Determination of the stability constants of lanthanide complexes with oxyacids using capillary electrophoresis [J].
Nikonorov, V. V. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (04) :359-365
[28]   Critical evaluation of stability constants for α-hydroxycarboxylic acid complexes with protons and metal ions and the accompanying enthalpy changes part II.: Aliphatic 2-hydroxycarboxylic acids [J].
Portanova, R ;
Lajunen, LHJ ;
Tolazzi, M ;
Piispanen, J .
PURE AND APPLIED CHEMISTRY, 2003, 75 (04) :495-540
[29]  
Rao A.L. J., 1986, REV ANAL CHEM, V8, P283
[30]   Separation and determination of lanthanides, thorium and uranium using a dual gradient in reversed-phase liquid chromatography [J].
Raut, NM ;
Jaison, PG ;
Aggarwal, SK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) :131-136