Lab in a syringe: fully automated dispersive liquid-liquid microextraction with integrated spectrophotometric detection

被引:86
作者
Maya, Fernando [1 ]
Horstkotte, Burkhard [2 ]
Manuel Estela, Jose [1 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Fac Sci, Dept Chem, Palma De Mallorca 07122, Illes Balears, Spain
[2] Mediterranean Inst Adv Studies, Dept Global Change Res, Esporles 07190, Spain
关键词
Dispersive liquid-liquid microextraction; Sequential injection analysis; Sample treatment automation; Fatty alcohols; Rhodamine B; ATOMIC-ABSORPTION-SPECTROMETRY; IONIC LIQUID; ORGANIC-COMPOUNDS; SOLVENTS LIGHTER; WATER SAMPLES; SYSTEM; EXTRACTION; CADMIUM; COBALT;
D O I
10.1007/s00216-012-6159-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new approach for the integration of various analytical steps inside a syringe (Lab in a Syringe) is presented. Fully automated dispersive liquid-liquid microextraction with integrated spectrophotometric detection is carried out in-syringe using a very simple instrumental setup. The lighter-than-water organic droplets released in the extraction step accumulate at the head of the syringe, where two optical fibers are placed on both sides of the syringe, facing each other and enabling the in situ quantification of the extracted compounds. By this, monitoring of the progressively accumulating droplet in the head of the syringe was further possible. In this first report, the developed instrumental setup has been applied to the determination of the dye rhodamine B in water samples and soft drinks. The main parameters influencing the extraction such as the selection of the extractant and disperser solvents, extractant/disperser and organic/water phase ratios, pH of the aqueous phase, extraction flow rates, and extraction time were investigated. Under the selected conditions, rhodamine B was quantified in a working range of 0.023-2 mg L-1 with a limit of detection of 0.007 mg L-1. Good repeatability values of up to 3.2 % (RSD) were obtained for ten consecutive extractions. The enrichment factor for a 1 mg L-1 rhodamine B standard was 23, and up to 51 extractions were accomplished in 1 h.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 30 条
[1]   Recent advances in coupling single-drop and dispersive liquid-liquid microextraction with UV-vis spectrophotometry and related detection techniques [J].
Andruch, Vasil ;
Kocurova, Livia ;
Balogh, Ioseph S. ;
Skrlikova, Jana .
MICROCHEMICAL JOURNAL, 2012, 102 :1-10
[2]   Automated on-line dispersive liquid-liquid microextraction based on a sequential injection system [J].
Andruch, Vasil ;
Cecilia Acebal, Carolina ;
Skrlikova, Jana ;
Sklenarova, Hana ;
Solich, Petr ;
Balogh, Ioseph S. ;
Billes, Ferenc ;
Kocurova, Livia .
MICROCHEMICAL JOURNAL, 2012, 100 :77-82
[3]   Sequential injection dispersive liquid-liquid microextraction based on fatty alcohols and poly(etheretherketone)-turnings for metal determination by flame atomic absorption spectrometry [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2011, 84 (05) :1215-1220
[4]   Development of a sequential injection dispersive liquid-liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: Determination of lead and cadmium in natural waters [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
ANALYTICA CHIMICA ACTA, 2010, 668 (01) :35-40
[5]   Recent developments in homogeneous and dispersive liquid-liquid extraction for inorganic elements determination. A review [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 80 (02) :413-421
[6]   On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 79 (01) :86-91
[7]   An online ionic liquid-based microextraction system coupled to electrothermal atomic absorption spectrometry for cobalt determination in environmental samples and pharmaceutical formulations [J].
Berton, Paula ;
Wuilloud, Rodolfo G. .
ANALYTICAL METHODS, 2011, 3 (03) :664-672
[8]   Development of an on-line temperature-assisted ionic liquid dispersive microextraction system for sensitive determination of vanadium in environmental and biological samples [J].
Berton, Paula ;
Martinis, Estefania M. ;
Wuilloud, Rodolfo G. .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) :721-728
[9]   Application of dispersive liquid-liquid microextraction and spectrophotometric detection to the rapid determination of rhodamine 6G in industrial effluents [J].
Biparva, Pourya ;
Ranjbari, Elias ;
Hadjmohammadi, Mohammad Reza .
ANALYTICA CHIMICA ACTA, 2010, 674 (02) :206-210
[10]   Recent development in liquid phase microextraction for determination of trace level concentration of metals-A review [J].
Dadfarnia, Shayessteh ;
Shabani, Ali Mohammad Haji .
ANALYTICA CHIMICA ACTA, 2010, 658 (02) :107-119