Negative electrospray ionization ion mobility spectrometry combined with microextraction in packed syringe for direct analysis of phenoxyacid herbicides in environmental waters

被引:34
|
作者
Jafari, Mohammad T. [1 ]
Saraji, Mohammad [1 ]
Yousefi, Shila [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Phenoxyacid herbicides; 2,4-D; Silvex; Haloxyfop; Microextraction in packed syringe; Negative electrospray ionization; Ion mobility spectrometry; SOLID-PHASE EXTRACTION; CHROMATOGRAPHY-MASS-SPECTROMETRY; ACID HERBICIDES; SAMPLE PREPARATION; DERIVATIZATION; SORBENT; CLEANUP; ONLINE; LC;
D O I
10.1016/j.chroma.2012.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method based on microextraction in packed syringe (MEPS) coupled with negative electrospray ionization-ion mobility spectrometry (ESI-IMS) was developed for simultaneous and direct determination of phenoxyacid herbicides in water samples. The effects of various parameters such as pH of the sample solution, sample loading rate, the nature of elution solvent and its volume, and the number of extraction cycles were investigated. The method was exhaustively validated in terms of sensitivity, recovery, reproducibility, and enrichment factor. The detection limits of the method for 2,4-D, silvex, and haloxyfop were found to be 60, 70, and 90 ng L-1, respectively. The recovery of the analyzed herbicides was in the range 73-102%, and the relative standard deviation (RSD) was lower than 10% for all the experiments. Various real samples were analyzed with the proposed method, and the obtained results revealed the efficient extraction of the analytes using MEPS extraction before the analysis by negative ESI-IMS. (C)2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [31] Multi-stage mass spectrometry of furostanol saponins combined with electrospray ionization in positive and negative ion modes
    Liu, YZ
    Liang, F
    Cui, LJ
    Xia, M
    Zhao, LY
    Yang, YC
    Shi, FG
    Abliz, Z
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (02) : 235 - 238
  • [32] Analysis of triacetone triperoxide complexes with alkali metal ions by electrospray and extractive electrospray ionisation combined with ion mobility spectrometry and mass spectrometry
    Hill, Alex R.
    Edgar, Mark
    Chatzigeorgiou, Maria
    Reynolds, James C.
    Kelly, Paul F.
    Creaser, Colin S.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2015, 21 (03) : 265 - 274
  • [33] Automated on-line in-tube solid-phase microextraction followed by liquid chromatography/electrospray ionization-mass spectrometry for the determination of chlorinated phenoxy acid herbicides in environmental waters
    Takino, M
    Daishima, S
    Nakahara, T
    ANALYST, 2001, 126 (05) : 602 - 608
  • [34] Electrospray ionization-ion mobility spectrometry: a rapid analytical method for aqueous nitrate and nitrite analysis
    Dwivedi, P
    Matz, LM
    Atkinson, DA
    Hill, HH
    ANALYST, 2004, 129 (02) : 139 - 144
  • [35] Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry
    Lee, Jihyeon
    Park, Sehwan
    Cho, Soo Gyeong
    Goh, Eun Mee
    Lee, Sungman
    Koh, Sung-Suk
    Kim, Jeongkwon
    TALANTA, 2014, 120 : 64 - 70
  • [36] Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry
    Gong, Lingzhi
    McCullagh, James S. O.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5480 - 5486
  • [37] Simultaneous determination of busulphan in plasma samples by liquid chromatography-electrospray ionization mass spectrometry utilizing microextraction in packed syringe (MEPS) as on-line sample preparation method
    Abdel-Rehim, Mohamed
    Hassan, Zuzana
    Skansem, Patrik
    Hassan, Moustapha
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (20) : 3029 - 3041
  • [38] Determination of the mitins, sulcofuron and flucofuron, using liquid chromatography combined with negative-ion electrospray ionization mass spectrometry
    Hancock, PM
    White, SJG
    Catlow, DA
    Baugh, PJ
    Bonwick, GA
    Davies, DH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (02) : 195 - 200
  • [39] Enhanced Direct Ambient Analysis by Differential Mobility-Filtered Desorption Electrospray Ionization-Mass Spectrometry
    Galhena, Asiri S.
    Harris, Glenn A.
    Kwasnik, Mark
    Fernandez, Facundo M.
    ANALYTICAL CHEMISTRY, 2010, 82 (22) : 9159 - 9163
  • [40] Aptamer based extraction followed by electrospray ionization-ion mobility spectrometry for analysis of tetracycline in biological fluids
    Aslipashaki, Shabnam Najafi
    Khayamian, Taghi
    Hashemian, Zahra
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 925 : 26 - 32