Negative electrospray ionization ion mobility spectrometry combined with microextraction in packed syringe for direct analysis of phenoxyacid herbicides in environmental waters

被引:34
|
作者
Jafari, Mohammad T. [1 ]
Saraji, Mohammad [1 ]
Yousefi, Shila [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Phenoxyacid herbicides; 2,4-D; Silvex; Haloxyfop; Microextraction in packed syringe; Negative electrospray ionization; Ion mobility spectrometry; SOLID-PHASE EXTRACTION; CHROMATOGRAPHY-MASS-SPECTROMETRY; ACID HERBICIDES; SAMPLE PREPARATION; DERIVATIZATION; SORBENT; CLEANUP; ONLINE; LC;
D O I
10.1016/j.chroma.2012.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method based on microextraction in packed syringe (MEPS) coupled with negative electrospray ionization-ion mobility spectrometry (ESI-IMS) was developed for simultaneous and direct determination of phenoxyacid herbicides in water samples. The effects of various parameters such as pH of the sample solution, sample loading rate, the nature of elution solvent and its volume, and the number of extraction cycles were investigated. The method was exhaustively validated in terms of sensitivity, recovery, reproducibility, and enrichment factor. The detection limits of the method for 2,4-D, silvex, and haloxyfop were found to be 60, 70, and 90 ng L-1, respectively. The recovery of the analyzed herbicides was in the range 73-102%, and the relative standard deviation (RSD) was lower than 10% for all the experiments. Various real samples were analyzed with the proposed method, and the obtained results revealed the efficient extraction of the analytes using MEPS extraction before the analysis by negative ESI-IMS. (C)2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [21] Hollow fiber-based liquid-liquid-liquid microextraction combined with electrospray ionization-ion mobility spectrometry for the determination of pentazocine in biological samples
    Saraji, Mohammad
    Jafari, Mohammad Taghi
    Sherafatmand, Hossein
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (32) : 5173 - 5178
  • [22] Analysis of tryptic peptides using desorption electrospray ionisation combined with ion mobility spectrometry/mass spectrometry
    Kaur-Atwal, Gushinder
    Weston, Daniel J.
    Green, Philip S.
    Crosland, Susan
    Bonner, Philip L. R.
    Creaser, Colin S.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (07) : 1131 - 1138
  • [23] Simultaneous Determination of Nitrite and Nitrate in Potato and Water Samples Using Negative Electrospray Ionization Ion Mobility Spectrometry
    M. T. Jafari
    F. Torki
    M. Saraji
    Analytical Sciences, 2012, 28 : 391 - 395
  • [24] Simultaneous determination of nitrite and nitrate in potato and water samples using negative electrospray ionization ion mobility spectrometry
    Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Iran
    Anal. Sci., 4 (391-396):
  • [25] Simultaneous Determination of Nitrite and Nitrate in Potato and Water Samples Using Negative Electrospray Ionization Ion Mobility Spectrometry
    Jafari, M. T.
    Torki, F.
    Saraji, M.
    ANALYTICAL SCIENCES, 2012, 28 (04) : 391 - 395
  • [26] Analysis of wastewater samples by direct combination of thin-film microextraction and desorption electrospray ionization mass spectrometry
    Strittmatter, Nicole
    Duering, Rolf-Alexander
    Takats, Zoltan
    ANALYST, 2012, 137 (17) : 4037 - 4044
  • [27] Tetramethylammonium Hydroxide as a Reagent for Complex Mixture Analysis by Negative Ion Electrospray Ionization Mass Spectrometry
    Lobodin, Vladislav V.
    Juyal, Priyanka
    McKenna, Amy M.
    Rodgers, Ryan P.
    Marshall, Alan G.
    ANALYTICAL CHEMISTRY, 2013, 85 (16) : 7803 - 7808
  • [28] Analysis of heparin oligosaccharides by capillary electrophoresis-negative-ion electrospray ionization mass spectrometry
    Lin, Lei
    Liu, Xinyue
    Zhang, Fuming
    Chi, Lianli
    Amster, I. Jonathan
    Leach, Franklyn E., III
    Xia, Qiangwei
    Linhardt, Robert J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (02) : 411 - 420
  • [29] Analysis of heparin oligosaccharides by capillary electrophoresis–negative-ion electrospray ionization mass spectrometry
    Lei Lin
    Xinyue Liu
    Fuming Zhang
    Lianli Chi
    I. Jonathan Amster
    Franklyn E. Leach
    Qiangwei Xia
    Robert J. Linhardt
    Analytical and Bioanalytical Chemistry, 2017, 409 : 411 - 420
  • [30] Applications of negative ion chemical ionization mass spectrometry technique in environmental analysis
    Gurprasad, NP
    Haidar, NA
    Manners, TG
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2002, 33 (15-18) : 3449 - 3456