Quantitative MRCP Imaging: Accuracy, Repeatability, Reproducibility, and Cohort-Derived Normative Ranges

被引:42
作者
Goldfinger, Marc H. [1 ]
Ridgway, Gerard R. [1 ]
Ferreira, Carlos [1 ]
Langford, Caitlin R. [1 ]
Cheng, Lin [1 ]
Kazimianec, Arina [1 ]
Borghetto, Andrea [1 ]
Wright, Thomas G. [1 ]
Woodward, Gary [1 ]
Hassanali, Neelam [1 ]
Nicholls, Rowan C. [1 ]
Simpson, Hayley [1 ]
Waddell, Tom [1 ]
Vikal, Siddarth [1 ]
Mavar, Marija [1 ]
Rymell, Soubera [1 ]
Wigley, Ioan [1 ]
Jacobs, Jaco [1 ]
Kelly, Matt [1 ]
Banerjee, Rajarshi [1 ]
Brady, J. Michael [1 ,2 ]
机构
[1] Perspectum Ltd, Oxford, England
[2] Univ Oxford, Dept Oncol, Med Sci Div, Oxford, England
关键词
magnetic resonance cholangiopancreatography (MRCP); biliary disease; repeatability; reproducibility; 3D-printed phantom; quantitative metrics; MAGNETIC-RESONANCE CHOLANGIOGRAPHY; BILE; CHOLANGIOPANCREATOGRAPHY; DIAGNOSIS; STONES;
D O I
10.1002/jmri.27113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Magnetic resonance cholangiopancreatography (MRCP) is an important tool for noninvasive imaging of biliary disease, however, its assessment is currently subjective, resulting in the need for objective biomarkers. Purpose To investigate the accuracy, scan/rescan repeatability, and cross-scanner reproducibility of a novel quantitative MRCP tool on phantoms and in vivo. Additionally, to report normative ranges derived from the healthy cohort for duct measurements and tree-level summary metrics. Study Type Prospective. Phantoms/Subjects Phantoms: two bespoke designs, one with varying tube-width, curvature, and orientation, and one exhibiting a complex structure based on a real biliary tree. Subjects Twenty healthy volunteers, 10 patients with biliary disease, and 10 with nonbiliary liver disease. Sequence/Field Strength MRCP data were acquired using heavily T-2-weighted 3D multishot fast/turbo spin echo acquisitions at 1.5T and 3T. Assessment Digital instances of the phantoms were synthesized with varying resolution and signal-to-noise ratio. Physical 3D-printed phantoms were scanned across six scanners (two field strengths for each of three manufacturers). Human subjects were imaged on four scanners (two fieldstrengths for each of two manufacturers). Statistical Tests Bland-Altman analysis and repeatability coefficient (RC). Results Accuracy of the diameter measurement approximated the scanning resolution, with 95% limits of agreement (LoA) from -1.1 to 1.0 mm. Excellent phantom repeatability was observed, with LoA from -0.4 to 0.4 mm. Good reproducibility was observed across the six scanners for both phantoms, with a range of LoA from -1.1 to 0.5 mm. Inter- and intraobserver agreement was high. Quantitative MRCP detected strictures and dilatations in the phantom with 76.6% and 85.9% sensitivity and 100% specificity in both. Patients and healthy volunteers exhibited significant differences in metrics including common bile duct (CBD) maximum diameter (7.6 mm vs. 5.2 mmP= 0.002), and overall biliary tree volume 12.36 mL vs. 4.61 mL,P= 0.0026). Data Conclusion The results indicate that quantitative MRCP provides accurate, repeatable, and reproducible measurements capable of objectively assessing cholangiopathic change. Evidence Level: 1 Technical Efficacy: Stage 2
引用
收藏
页码:807 / 820
页数:14
相关论文
共 37 条
[1]  
Alberto E, 2015, REV COLOMB GASTROENT, V27, P580
[2]   Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease [J].
Banerjee, Rajarshi ;
Pavlides, Michael ;
Tunnicliffe, Elizabeth M. ;
Piechnik, Stefan K. ;
Sarania, Nikita ;
Philips, Rachel ;
Collier, Jane D. ;
Booth, Jonathan C. ;
Schneider, Jurgen E. ;
Wang, Lai Mun ;
Delaney, David W. ;
Fleming, Ken A. ;
Robson, Matthew D. ;
Barnes, Eleanor ;
Neubauer, Stefan .
JOURNAL OF HEPATOLOGY, 2014, 60 (01) :69-77
[3]   The effective use of acai juice, blueberry juice and pineapple juice as negative contrast agents for magnetic resonance cholangiopancreatography in children [J].
Bittman, Mark E. ;
Callahan, Michael J. .
PEDIATRIC RADIOLOGY, 2014, 44 (07) :883-887
[4]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[5]   Diagnosis and Management of Primary Sclerosing Cholangitis [J].
Chapman, Roger ;
Fevery, Johan ;
Kalloo, Anthony ;
Nagorney, David M. ;
Boberg, Kirsten Muri ;
Shneider, Benjamin ;
Gores, Gregory J. .
HEPATOLOGY, 2010, 51 (02) :660-678
[6]   Anatomic variation in intrahepatic bile ducts: An analysis of intraoperative cholangiograms in 300 consecutive donors for living donor liver transplantation [J].
Choi, JW ;
Kim, TK ;
Kim, KW ;
Kim, AY ;
Kim, PN ;
Ha, HK ;
Lee, MG .
KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (02) :85-90
[7]  
EA Sasse, 2000, DEFINE DETERMINE REF, V20
[8]  
Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
[9]   Inflammation and the Gut-Liver Axis in the Pathophysiology of Cholangiopathies [J].
Giordano, Debora Maria ;
Pinto, Claudio ;
Maroni, Luca ;
Benedetti, Antonio ;
Marzioni, Marco .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (10)
[10]   On the appearance of bile in clinical MR cholangiopancreatography [J].
Håkansson, K ;
Christoffersson, JO ;
Leander, P ;
Ekberg, O ;
Håkansson, HO .
ACTA RADIOLOGICA, 2002, 43 (04) :401-410