Quantitative monitoring of corticosteroids in cosmetic products manufactured in Korea using LC-MS/MS

被引:31
作者
Nam, Yun Sik [1 ,2 ,3 ]
Kwon, Il Keun [2 ,3 ]
Lee, Yeonhee [1 ]
Lee, Kang-Bong [1 ]
机构
[1] Korea Inst Sci & Technol, Adv Anal Ctr, Seoul 136791, South Korea
[2] Kyung Hee Univ, Dept Oral Biol, Sch Dent, Seoul 130701, South Korea
[3] Kyung Hee Univ, Inst Oral Biol, Sch Dent, Seoul 130701, South Korea
关键词
Prednisolone; Hydrocortisone; Betamethasone; Dexamethasone and triamcinolone acetonide; LC-MS/MS; Cosmetic products; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; CLOBETASOL PROPIONATE; DEXAMETHASONE; GLUCOCORTICOIDS; BETAMETHASONE; PLASMA; CORTISOL; DIFFERENTIATION; QUANTIFICATION;
D O I
10.1016/j.forsciint.2011.12.011
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Some cosmetic products manufactured in Korea for the treatment of eczema, seborrhea and psoriasis have been suspected to contain anti-inflammatory corticosteroids such as prednisolone, hydrocortisone, betamethasone, dexamethasone and triamcinolone acetonide without these ingredients being indicated on the label. Due to their severe side effects such as permenent skin atopy, these corticosteroids have to be monitored in cosmetic products from a forensic point of view. Many cosmetic product samples (N = 65) have been collected from both local and online markets in Korea. The corticosteroid content of these samples was analyzed by LC-MS/MS with diagnostic ions (m/z). Linearity was studied with 0.1-10 mg/mL range in all corticosteroids. Good correlation coefficients (r(2) >= 0.997) were found and the limits of quantification were 4.68-7.97 ng/mL for each of the corticosteroids. At three different concentrations spanning the linear dynamic ranges, mean recoveries were 97.2-113.5% and precisions (RSD) for intra-day and inter-day analysis were less than 8.9%. Also, accuracy (Bias %) was less than 11.8%. The results showed that between 0.76-0.94 mg/g levels of prednisolone were detected in four cosmetic products and triamcinolone acetonide was detected with a concentration in the range of 11.5-272 mg/g in nine samples. This fact reveals that some manufacturers have arbitrarily added these corticosteroids in their cosmetic products without indicating them on the label. Thus, these cosmetic products have to be monitored and if proven illegal preparations removed from the market. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E23 / E28
页数:6
相关论文
共 24 条
[1]   Simple liquid chromatography method for the rapid simultaneous determination of prednisolone and cortisol in plasma and urine using hydrophilic lipophilic balanced solid phase extraction cartridges [J].
AbuRuz, S ;
Millership, J ;
Heaney, L ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (02) :193-201
[2]   Differentiation of betamethasone and dexamethasone using liquid chromatography/positive electrospray tandem mass spectrometry and multivariate statistical analysis [J].
Antignac, JP ;
Le Bizec, B ;
Monteau, F ;
Andre, F .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (01) :69-75
[3]  
Antignac JP, 2000, RAPID COMMUN MASS SP, V14, P33, DOI 10.1002/(SICI)1097-0231(20000115)14:1<33::AID-RCM829>3.0.CO
[4]  
2-R
[5]   Differentiation between dexamethasone and betamethasone in a mixture using multiple mass spectrometry [J].
De Wasch, K ;
De Brabander, HF ;
Van de Wiele, M ;
Vercammen, J ;
Courtheyn, D ;
Impens, S .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :79-86
[6]   Topical Clobetasol Propionate in the Treatment of Psoriasis A Review of Newer Formulations [J].
Feldman, Steven R. ;
Yentzer, Brad A. .
AMERICAN JOURNAL OF CLINICAL DERMATOLOGY, 2009, 10 (06) :397-406
[7]   Determination of the glucocorticoids prednisone, prednisolone, dexamethasone, and cortisol in human serum using liquid chromatography coupled to tandem mass spectrometry [J].
Frerichs, VA ;
Tornatore, KM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02) :329-338
[8]   Quantitative measurements of corticosteroids in ex vivo samples using on-line SPE-LC/MS/MS [J].
Gao, Lan ;
Chiou, William J. ;
Camp, Heidi S. ;
Burns, David J. ;
Cheng, Xueheng .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03) :303-310
[9]   "For export only" medicines come back to Europe: A RP-LC method for the screening of six glucocorticoids in illegal and counterfeit anti-inflammatory and lightening creams [J].
Gaudiano, M. C. ;
Lucente, D. ;
Antoniella, E. ;
Bertocchi, P. ;
Muleri, N. ;
Manna, L. ;
Bartolomei, M. ;
Alimonti, S. ;
Valvo, L. ;
Rodomonte, A. L. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (02) :158-164
[10]   Simultaneous analysis of twenty-one glucocorticoids in equine plasma by liquid chromatography/tandem mass spectrometry [J].
Luo, Y ;
Uboh, CE ;
Soma, LR ;
Guan, FY ;
Rudy, JA ;
Tsang, DS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (10) :1245-1256