Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging

被引:27
作者
Lazennec, Jean Yves [1 ,2 ,3 ]
Brusson, Adrien [3 ]
Dominique, Folinais [5 ]
Rousseau, Marc-Antoine [2 ,3 ,4 ]
Pour, Aidin Eslam [6 ]
机构
[1] UPMC, Hop La Pitie Salpetriere, AP HP, Dept Orthopaed & Trauma Surg, F-75013 Paris, France
[2] Arts & Metiers Paris Tech, Biomechan Lab LBM, Paris, France
[3] UPMC, Dept Anat, F-75013 Paris, France
[4] Avicenne Hosp, AP HP, Dept Orthopaed & Trauma Surg, F-93009 Bobigny, France
[5] RIM Maussins Nollet, F-75017 Paris, France
[6] Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI 48109 USA
关键词
Total hip arthroplasty; Offset and anteversion; Two-dimensional imaging; Three-dimensional imaging; EOS imaging system; ABDUCTOR MUSCLE STRENGTH; FEMORAL ANTEVERSION; 3D RECONSTRUCTION; COMPUTED-TOMOGRAPHY; MODULAR NECK; RADIOGRAPHY; CT; OSTEOARTHRITIS; VALIDATION; PRECISION;
D O I
10.1007/s00264-014-2616-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Accurate evaluation of femoral offset is difficult with conventional anteroposterior (AP) X-rays. The EOS imaging system is a system that makes the acquisition of simultaneous and orthogonal AP and lateral images of the patient in the standing position possible. These two-dimensional (2D) images are equivalent to standard plane X-rays. Three-dimensional (3D) reconstructions are obtained from these paired images according to a validated protocol. This prospective study explores the value of the EOS imaging system for comparing measurements of femoral offset from these 2D images and the 3D reconstructions. Methods We included 110 patients with unilateral total hip arthroplasty (THA). The 2D offset was measured on the AP view with the same protocol as for standard X-rays. The 3D offset was calculated from the reconstructions based on the orthogonal AP and lateral views. Reproducibility and repeatability studies were conducted for each measurement. We compared the 2D and 3D offset for both hips (with and without THA). Results For the global series (110 hips with and 110 without THA), 2D offset was 40 mm (SD 7.3; 7-57 mm). The standard deviation was 6.5 mm for repeatability and 7.5 mm for reproducibility. Three-dimensional offset was 43 mm (SD 6.6; 22-62 mm), with a standard deviation of 4.6 for repeatability and 5.5 for reproducibility. Two-dimensional offset for the hips without THA was 40 mm (SD 7.0; 26-56 mm), and 3D offset 43 mm (SD 6.6; 28-62 mm). For THA side, 2D offset was 41 mm (SD 8.2; 7-57 mm) and 3D offset 45 mm (SD 4.8; 22-61 mm). Comparison of the two protocols shows a significant difference between the 2D and 3D measurements, with the 3D offset having higher values. Comparison of the side with and without surgery for each case showed a 5-mm deficit for the offset in 35 % of the patients according to the 2D measurement but in only 26 % according to the 3D calculation. Conclusions This study points out the limitations of 2D measurements of femoral offset on standard plane X-rays. The reliability of the EOS 3D models has been previously demonstrated with CT scan reconstructions as a reference. The EOS imaging system could be an option for obtaining accurate and reliable offset measurements while significantly limiting the patient's exposure to radiation.
引用
收藏
页码:1259 / 1267
页数:9
相关论文
共 51 条
[1]   Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty [J].
Asayama, I ;
Chamnongkich, S ;
Simpson, KJ ;
Kinsey, TL ;
Mahoney, OM .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :414-420
[2]   Soft tissue balancing - The hip [J].
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :17-22
[3]   Femoral and Tibial Torsion Measurements With 3D Models Based on Low-Dose Biplanar Radiographs in Comparison With Standard CT Measurements [J].
Buck, Florian M. ;
Guggenberger, Roman ;
Koch, Peter P. ;
Pfirrmann, Christian W. A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :W607-W612
[4]   DETERMINATION OF ACCURACY OF PREOPERATIVE TEMPLATING OF NONCEMENTED FEMORAL PROSTHESES [J].
CARTER, LW ;
STOVALL, DO ;
YOUNG, TR .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :507-513
[5]   Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays [J].
Chaibi, Y. ;
Cresson, T. ;
Aubert, B. ;
Hausselle, J. ;
Neyret, P. ;
Hauger, O. ;
de Guise, J. A. ;
Skalli, W. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) :457-466
[6]  
Charles Mark N, 2005, Instr Course Lect, V54, P131
[7]   Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck [J].
Cooper, H. John ;
Urban, Robert M. ;
Wixson, Richard L. ;
Meneghini, R. Michael ;
Jacobs, Joshua J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (10) :865-872
[8]  
de Thomasson E, 2002, REV CHIR ORTHOP, V88, P229
[9]   The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty [J].
Della Valle, AG ;
Slullitel, G ;
Piccaluga, F ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :51-58
[10]  
Delp SL, 1996, CLIN ORTHOP RELAT R, P137