Repeatability of Meibomian Gland Contrast, a Potential Indicator of Meibomian Gland Function

被引:22
|
作者
Yeh, Thao N. [1 ,2 ]
Lin, Meng C. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Clin Res Ctr, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Sch Optometry, Vis Sci Grp, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
tear lipid layer; meibomian gland; tear film stability; meibomian gland expressibility; meibography; evaporative dry eye; meibomian gland dysfunction; meibomian gland contrast; isotretinoin; 13-cis-retinoic acid; accutane; contrast; meibomian gland intensity; intensity; dry eye; dry eye disease; repeatability; limits of agreement; 13-CIS RETINOIC ACID; TEAR-FILM; INTERNATIONAL WORKSHOP; ANDROGEN DEFICIENCY; RISK-FACTORS; DYSFUNCTION; PREVALENCE; DISCOMFORT;
D O I
10.1097/ICO.0000000000001818
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Meibomian gland contrast may be a potential indicator of gland health, especially among isotretinoin users. We aimed to develop a repeatable and reliable method for measuring Meibomian gland contrast from meibography images. Methods: Lower lid (LL) and upper lid (UL) meibography were captured with the OCULUS Keratograph 5M (OCULUS, Inc) at 2 visits under the following 4 conditions: face centered with room lights on (C), left-turned face (L), right-turned face (R), and face centered with room lights off (CLO). Contrast was measured with Fiji (v2.0.0-rc-59). Coefficient of repeatability and limits of agreement (LOA) were determined using Bland-Altman plots. Results: A total of 512 meibography images from 16 subjects (age +/- SD = 24.8 +/- 5.2 years; 13 female patients) were collected. Coefficient of repeatability between visits was 10.5 for UL and 14.9 for LL. Lower and upper LOA, respectively, for UL, compared with condition C, were -10.9 [95% confidence interval (CI), -13.5 to -8.3] and 6.2 (95% CI, 3.6-8.8) for L; -11.0 (95% CI, -13.8 to -8.1) and 7.0 (95% CI, 4.2-9.8) for R; and -9.0 (95% CI, -11.6 to -6.5) and 7.2 (95% CI, 4.7-9.8) for CLO. Lower and upper LOA, respectively, for LL, compared with condition C, were -18.1 (95% CI, -22.6 to -13.5) and 11.0 (95% CI, 6.5-15.5) for L; -15.3 (95% CI, -19.2 to -11.3) and 9.9 (95% CI, 6.0-13.9) for R; and -12.0 (95% CI, -15.1 to -8.8) and 8.2 (95% CI, 5.0-11.3) for CLO. Conclusions: Meibomian gland contrast is a repeatable and reliable measure for changes in Meibomian gland contrast greater than 11 in the UL and 18 in the LL.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [1] Meibomian Gland Morphology Is a Sensitive Early Indicator of Meibomian Gland Dysfunction
    Adil, Mohammed Yasin
    Xiao, Jiaxin
    Olafsson, Jonatan
    Chen, Xiangjun
    Lagali, Neil S.
    Raeder, Sten
    Utheim, Oygunn A.
    Dartt, Darlene A.
    Utheim, Tor P.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 200 : 16 - 25
  • [2] Evaluation of Meibomian gland structure and appearance after therapeutic Meibomian gland expression
    Swiderska, Kasandra
    Blackie, Caroline A.
    Maldonado-Codina, Carole
    Fergie, Martin
    Read, Michael L.
    Morgan, Philip B.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (05) : 504 - 514
  • [3] Effect of the Meibomian Gland Squeezer for Treatment of Meibomian Gland Dysfunction
    Wang, Da-Hu
    Liu, Xin-Quan
    Hao, Xiao-Jun
    Zhang, Yin-Jian
    Zhu, Hua-Ying
    Dong, Zhi-Guo
    CORNEA, 2018, 37 (10) : 1270 - 1278
  • [4] The Role of Soft Contact Lens Wear on Meibomian Gland Morphology and Function
    Ucakhan, Omur
    Arslanturk-Eren, Mehtap
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (05): : 292 - 300
  • [5] Repeatability of Grading Meibomian Gland Dropout Using Two Infrared Systems
    Ngo, William
    Srinivasan, Sruthi
    Schulze, Marc
    Jones, Lyndon
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (06) : 658 - 667
  • [6] Intense pulsed light treatment and meibomian gland expression for moderate to advanced meibomian gland dysfunction
    Albietz, Julie M.
    Schmid, Katrina L.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2018, 101 (01) : 23 - 33
  • [7] Meibomian Gland Dysfunction
    Finis, D.
    Schrader, S.
    Geerling, G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (05) : 506 - 513
  • [8] Uneven Meibomian Gland Dropout Over the Tarsal Plate and Its Correlation With Meibomian Gland Dysfunction
    Yin, Yue
    Gong, Lan
    CORNEA, 2015, 34 (10) : 1200 - 1205
  • [9] Transitory alkali exposure on meibomian gland orifices induces meibomian gland dysfunction
    Bu, Jinghua
    Wu, Yang
    Li, Kechun
    Zhang, Minjie
    Zhang, Rongrong
    Sun, Le
    Guo, Yuli
    He, Hui
    Li, Shiying
    Liu, Zuguo
    Li, Wei
    OCULAR SURFACE, 2023, 29 : 406 - 415
  • [10] Tear and Meibomian Gland Function in Blepharitis and Normals
    McCann, Louise C.
    Tomlinson, Alan
    Pearce, Edward I.
    Diaper, Charles
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (04): : 203 - 208