Quantifying the centre of rotation pattern in a multi-body model of the lumbar spine

被引:9
作者
Abouhossein, Alireza [1 ,2 ]
Weisse, Bernhard [1 ]
Ferguson, Stephen J. [2 ,3 ]
机构
[1] EMPA, Swiss Fed Labs Mat Testing & Res, Lab Mech Syst Engn, CH-8600 Dubendorf, Switzerland
[2] Univ Bern, Inst Surg Technol & Biomech, Bern, Switzerland
[3] ETH, Inst Biomech, Zurich, Switzerland
关键词
rigid body simulation; lumbar spine; instantaneous centre of rotation; unit quaternions; INTRADISCAL PRESSURE; INSTANTANEOUS CENTER; MECHANICAL-BEHAVIOR; STEPWISE REDUCTION; MOTION; JOINT; FLEXION/EXTENSION; FORCES; KINEMATICS; STIFFNESS;
D O I
10.1080/10255842.2012.671306
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Understanding the kinematics of the spine provides paramount knowledge for many aspects of the clinical analysis of back pain. More specifically, visualisation of the instantaneous centre of rotation (ICR) enables clinicians to quantify joint laxity in the segments, avoiding a dependence on more inconclusive measurements based on the range of motion and excessive translations, which vary in every individual. Alternatively, it provides motion preserving designers with an insight into where a physiological ICR of a motion preserving prosthesis can be situated in order to restore proper load distribution across the passive and active elements of the lumbar region. Prior to the use of an unconstrained dynamic musculoskeletal model system, based on multi-body models capable of transient analysis, to estimate segmental loads, the model must be kinematically evaluated for all possible sensitivity due to ligament properties and the initial locus of intervertebral disc (IVD). A previously calibrated osseoligamentous model of lumbar spine was used to evaluate the changes in ICR under variation of the ligament stiffness and initial locus of IVD, when subjected to pure moments from 0 to 15Nm. The ICR was quantified based on the closed solution of unit quaternion that improves accuracy and prevents coordinate singularities, which is often observed in Euler-based methods and least squares principles. The calculation of the ICR during flexion/extension revealed complexity and intrinsic nonlinearity between flexion and extension. This study revealed that, to accommodate a good agreement between in vitro data and the multi-body model predictions, in flexion more laxity is required than in extension. The results showed that the ICR location is concentrated in the posterior region of the disc, in agreement with previous experimental studies. However, the current multi-body model demonstrates a sensitivity to the initial definition of the ICR, which should be recognised as a limitation of the method. Nevertheless, the current simulations suggest that, due to the constantly evolving path of the ICR across the IVD during flexion-extension, a movable ICR is a necessary condition in multi-body modelling of the spine, in the context of whole body simulation, to accurately capture segmental kinematics and kinetics.
引用
收藏
页码:1362 / 1373
页数:12
相关论文
共 39 条
  • [11] Stepwise reduction of functional spinal structures increase vertebral translation and intradiscal pressure
    Heuer, Frank
    Schmidt, Hendrik
    Claes, Lutz
    Wilke, Hans-Joachim
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (04) : 795 - 803
  • [12] Stepwise reduction of functional spinal structures increase range of motion and change lordosis angle
    Heuer, Frank
    Schmidt, Hendrik
    Klezl, Zdenek
    Claes, Lutz
    Wilke, Hans-Joachim
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (02) : 271 - 280
  • [13] CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS
    HORN, BKP
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04): : 629 - 642
  • [14] Finite helical axes of motion are a useful tool to describe the three-dimensional in vitro kinematics of the intact, injured and stabilised spine
    Kettler, A
    Marin, F
    Sattelmayer, G
    Mohr, M
    Mannel, H
    Dürselen, L
    Claes, L
    Wilke, HJ
    [J]. EUROPEAN SPINE JOURNAL, 2004, 13 (06) : 553 - 559
  • [15] Long A J, 1993, Proc Inst Mech Eng H, V207, P73, DOI 10.1243/PIME_PROC_1993_207_273_02
  • [16] Instant center of rotation estimation using the Reuleaux technique and a Lateral Extrapolation technique
    Moorehead, JD
    Montgomery, SC
    Harvey, DM
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (09) : 1301 - 1307
  • [17] The effect of dynamic posterior stabilization on facet joint contact forces
    Niosi, Christina A.
    Wilson, Derek C.
    Zhu, Qingan
    Keynan, Ory
    Wilson, David R.
    Oxland, Thomas R.
    [J]. SPINE, 2008, 33 (01) : 19 - 26
  • [18] CENTRODE PATTERNS IN THE LUMBAR SPINE - BASE-LINE STUDIES IN NORMAL SUBJECTS
    OGSTON, NG
    KING, GJ
    GERTZBEIN, SD
    TILE, M
    KAPASOURI, A
    RUBENSTEIN, JD
    [J]. SPINE, 1986, 11 (06) : 591 - 595
  • [19] CENTERS AND ANGLES OF ROTATION OF BODY JOINTS - STUDY OF ERRORS AND OPTIMIZATION
    PANJABI, MM
    [J]. JOURNAL OF BIOMECHANICS, 1979, 12 (12) : 911 - 920
  • [20] A TECHNIQUE FOR MEASUREMENT AND DESCRIPTION OF 3-DIMENSIONAL 6-DEGREE-OF-FREEDOM MOTION OF A BODY JOINT WITH AN APPLICATION TO THE HUMAN SPINE
    PANJABI, MM
    KRAG, MH
    GOEL, VK
    [J]. JOURNAL OF BIOMECHANICS, 1981, 14 (07) : 447 - +