Maintenance and Energy Optimization of Lighting Systems for the Improvement of Historic Buildings: A Case Study

被引:35
|
作者
Salata, Ferdinando [1 ]
Golasi, Iacopo [1 ]
Falanga, Giacomo [1 ]
Allegri, Marco [1 ]
Vollaro, Emanuele de Lieto [2 ]
Nardecchia, Fabio [1 ]
Pagliaro, Francesca [1 ]
Gugliermetti, Franco [1 ]
Vollaro, Andrea de Lieto [1 ]
机构
[1] Univ Roma La Sapienza, DIAEE Area Fis Tecn, I-00184 Rome, Italy
[2] Univ Roma TRE, DIMI, I-00146 Rome, Italy
来源
SUSTAINABILITY | 2015年 / 7卷 / 08期
关键词
lighting simulations; LED; historic buildings; maintenance; economic analysis; RELIABILITY; PERFORMANCE; TECHNOLOGIES; EFFICIENCY; SAVINGS;
D O I
10.3390/su70810770
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Proper lighting is vital to improve, from an artistic point of view, the surface expanse and decorative detailing of architectural heritage buildings considered valuable. When properly lit, monumental buildings can become to onlookers an essential part of the city. Nowadays, for design planners dealing with the improvement of buildings, whose architectural design should be valorized, the real challenge is to combine the lighting artistic requirements with scrupulous economic management in order to limit the energy demand and to respect the environment. For these reasons, this case study examines the lighting of the monumental facade and the cloister of St. Peter in Chains situated in the Faculty of Engineering of Sapienza University of Rome. The present lighting installation, characterized by metal halides, compact fluorescent and halogen lamps, is compared with an alternative scenario presenting LED lamps and scenographic lighting of the monumental facade. Such comparison is based on the evaluation of the lighting levels for different visual tasks and on energy and maintenance issues; the first analysis was performed through the software DIALux Evo 4.0, whereas the second was performed using ecoCALC. This study leads to the conclusion that the lighting levels of the solution presenting LED lamps are better than those of the present solution, and they comply with current standards. Finally, the higher costs of LED lamp installations and the scenographic lighting of the monumental facade are balanced by lower maintenance costs, with a payback period of seven years.
引用
收藏
页码:10770 / 10788
页数:19
相关论文
共 50 条
  • [41] Impact Of Energy Efficient LED Lighting On Overall Energy Use Intensity In Commercial Buildings: A Case Study Of Co-op House
    Murithi, Nancy Mwari
    Moses, Peter Musau
    Nyete, Abraham
    2021 IEEE PES/IAS POWERAFRICA CONFERENCE, 2021, : 313 - 317
  • [42] A METHOD TO ESTIMATE SAVINGS OF LED LIGHTING INSTALATION IN PUBLIC BUILDINGS The Case Study of Secondary Schools in Serbia
    Josijevic, Mladen M.
    Gordic, Dusan R.
    Milovanovic, Dobrica M.
    Jurisevic, Nebolsa M.
    Rakic, Nikola Z.
    THERMAL SCIENCE, 2017, 21 (06): : 2931 - 2943
  • [43] Impact of building automation control systems and technical building management systems on the energy performance class of residential buildings: An Italian case study
    Ippolito, M. G.
    Sanseverino, E. Riva
    Zizzo, G.
    ENERGY AND BUILDINGS, 2014, 69 : 33 - 40
  • [44] An optimization method applied to active solar energy systems for buildings in cold plateau areas - The case of Lhasa
    Si, Pengfei
    Feng, Ya
    Lv, Yuexia
    Rong, Xiangyang
    Pan, Yungang
    Liu, Xichen
    Yan, Jinyue
    APPLIED ENERGY, 2017, 194 : 487 - 498
  • [45] Plus Energy Buildings: A Numerical Case Study
    Hawila, Abed
    Alsalloum, Hala
    Merabtine, Abdelatif
    Fardoun, Farouk
    Bennacer, Rachid
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2023, 19 (01): : 117 - 134
  • [46] Multi-objective optimization of safety instrumented systems maintenance strategy: a case study
    Touahar, Hafed
    Ouazraoui, Nouara
    Khanfri, Nor El Houda
    Korichi, Mourad
    Bachi, Bilal
    Boukrouma, Houcem Eddine
    INTERNATIONAL JOURNAL OF QUALITY & RELIABILITY MANAGEMENT, 2021, 38 (08) : 1792 - 1815
  • [47] Energy refurbishment of historical buildings with public function: pilot case study
    Pisello, Anna Laura
    Petrozzi, Alessandro
    Castaldo, Veronica Lucia
    Cotana, Franco
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 660 - 663
  • [48] Toward the energy optimization of smart lighting systems through the luminous potential of photoluminescence
    Chiatti, Chiara
    Fabiani, Claudia
    Pisello, Anna Laura
    ENERGY, 2023, 266
  • [49] Evaluation of indoor environment and energy performance of dwellings in heritage buildings. The case of hot summers in historic cities in Mediterranean Europe
    Caro, Rosana
    Jose Sendra, Juan
    SUSTAINABLE CITIES AND SOCIETY, 2020, 52
  • [50] Retrofit Proposals for Energy Efficiency and Thermal Comfort in Historic Public Buildings: The Case of the Engineering Faculty's Seat of Sapienza University
    Vallati, Andrea
    Di Matteo, Miriam
    Fiorini, Costanza Vittoria
    ENERGIES, 2023, 16 (01)