System Identification of Biomedical Systems from Short Transients Using Space Methods

被引:2
作者
Zhao, Y. [1 ]
Kearney, R. E. [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
来源
2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-8 | 2008年
关键词
biomedical system with short transients; ensemble system identification; subspace method;
D O I
10.1109/IEMBS.2008.4649148
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
System identification technology has been a popular tool to analysis the dynamic behavior of biomedical systems. A segment of data with enough information must be collected in order to obtain unbiased estimate of the systems. However, some biomedical systems have short transients, such as Vestibulo-Ocular Reflex (VOR). Systems often cannot be Identified from the short transients collected in one experiment. Thus, the experiments must be repeated, and an ensemble of input and output recorded. This paper presents a subspace method to identify Multiple Input and Multiple Output (MIMO) state space models for biomedical systems from short transients using ensemble data. A simulating ankle joint stiffness experiment demonstrates that the algorithm provides accurate results.