No consistent risk factor pattern for symptoms related to the sick building syndrome:: a prospective population based study

被引:25
作者
Brauer, Charlotte
Kolstad, Henrik
Orbaek, Palle
Mikkelsen, Sigurd
机构
[1] Amtssygehuset i Glostrup, Arbejdsmed Klin, DK-2600 Glostrup, Denmark
[2] Copenhagen Univ Hosp, Dept Occupat Med, Glostrup, Denmark
[3] Aarhus Univ, Dept Occupat Med, Aarhus, Denmark
[4] Natl Inst Occupat Hlth, Copenhagen, Denmark
关键词
sick building syndrome; epidemiological study; cohort study; risk factors; indoor air quality;
D O I
10.1007/s00420-005-0074-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: To examine associations between perceived indoor environment at work and the non-specific symptoms that are often referred to as the sick building syndrome (SBS), using cross-sectional and prospective analyses for a large cohort from the general population. Methods: The sample comprised 2,164 adults in employment, who completed a postal questionnaire in April 2001. Of these 1,402, who were still working and living in the same place, completed a second questionnaire a year later. The outcome measures were the prevalence of mucous membrane symptoms and general symptoms at baseline and the incidence and persistence of these symptoms at follow-up. Self-reports of the indoor environment from the baseline questionnaire were used as predictors in the analyses. Results: Inconsistent results were found between the cross-sectional and the longitudinal analyses for the associations between perceived indoor environment factors at work and symptoms. Whereas mucous membrane symptoms in the cross-sectional analysis were significantly associated with self-reported high temperature and dry air, the prospective analyses showed that onset of mucous membrane symptoms was associated with the sensation of draught, dry air, and noise. Persistent mucous membrane symptoms were associated only with stuffy air. General symptoms were associated with self-reported stuffy air and dry air in the cross-sectional analysis, while draught was the only predictor of onset of general symptoms. We found no predictors in the indoor environment for the persistence of general symptoms. Conclusions: The symptoms that are often connected with SBS are very common symptoms in the general population among manual workers as well as non-manual workers. Our study gives only limited support to the hypothesis of causal relationships between the indoor environment and these symptoms. We found no evidence of persistent mucous membrane symptoms and general symptoms related to specific factors in the indoor environment.
引用
收藏
页码:453 / 464
页数:12
相关论文
共 45 条
[31]   Effects of temperature and humidification in the office environment [J].
Reinikainen, LM ;
Jaakkola, JJK .
ARCHIVES OF ENVIRONMENTAL HEALTH, 2001, 56 (04) :365-368
[32]   BUILDING SICKNESS, ARE SYMPTOMS RELATED TO THE OFFICE LIGHTING [J].
ROBERTSON, AS ;
MCINNES, M ;
GLASS, D ;
DALTON, G ;
BURGE, PS .
ANNALS OF OCCUPATIONAL HYGIENE, 1989, 33 (01) :47-59
[33]   THE STRESS PROFILE - A PSYCHOSOCIAL APPROACH TO MEASURING STRESS [J].
SETTERLIND, S ;
LARSON, G .
STRESS MEDICINE, 1995, 11 (02) :85-92
[34]  
Siegrist J, 1996, J Occup Health Psychol, V1, P27, DOI 10.1037/1076-8998.1.1.27
[35]   THE SICK BUILDING SYNDROME IN THE OFFICE ENVIRONMENT - THE DANISH TOWN HALL STUDY [J].
SKOV, P ;
VALBJORN, O .
ENVIRONMENT INTERNATIONAL, 1987, 13 (4-5) :339-349
[36]   INFLUENCE OF INDOOR CLIMATE ON THE SICK BUILDING SYNDROME IN AN OFFICE ENVIRONMENT [J].
SKOV, P ;
VALBJORN, O ;
PEDERSEN, BV .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1990, 16 (05) :363-371
[37]   FIGURING OUT FACTORS - THE USE AND MISUSE OF FACTOR-ANALYSIS [J].
STREINER, DL .
CANADIAN JOURNAL OF PSYCHIATRY-REVUE CANADIENNE DE PSYCHIATRIE, 1994, 39 (03) :135-140
[38]   SICK BUILDING SYNDROME (SBS) IN OFFICE WORKERS AND FACIAL SKIN SYMPTOMS AMONG VDT-WORKERS IN RELATION TO BUILDING AND ROOM CHARACTERISTICS - 2 CASE-REFERENT STUDIES [J].
SUNDELL, J ;
LINDVALL, T ;
STENBERG, B ;
WALL, S .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :83-94
[39]   Performance of noise indices in air-conditioned landscaped office buildings [J].
Tang, SK .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (03) :1657-1663
[40]   Air movement - good or bad? [J].
Toftum, J .