Anatomical consideration for optimal position of orthodontic miniscrews in the maxilla: a CBCT appraisal

被引:13
作者
Al Amri, Maha S. [1 ]
Sabban, Hanadi M. [2 ]
Alsaggaf, Doaa H. [1 ]
Alsulaimani, Fahad F. [1 ]
Al-Turki, Ghassan A. [1 ]
Al-Zahrani, Mohammad S. [3 ]
Zawawi, Khalid H. [1 ]
机构
[1] King Abdulaziz Univ, Fac Dent, Dept Orthodont, POB 80209, Jeddah 21589, Saudi Arabia
[2] King Abdulaziz Univ, Fac Dent, Dept Oral Diagnost Sci, Jeddah, Saudi Arabia
[3] King Abdulaziz Univ, Fac Dent, Dept Periodont, Jeddah, Saudi Arabia
关键词
CORTICAL-BONE THICKNESS; BEAM COMPUTED-TOMOGRAPHY; MINI-IMPLANT PLACEMENT; INFRAZYGOMATIC CREST; INSERTION; ANCHORAGE; SITES; SUCCESS; QUANTITY; QUALITY;
D O I
10.5144/0256-4947.2020.330
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Orthodontic miniscrews are commonly used as temporary anchorage devices. Bone thickness and bone depth are important factors when placing miniscrews. There are no studies to assess the maxillary bone thickness for optimum miniscrew placement in a Saudi population. OBJECTIVE: Assess the proximity of the maxillary sinus and nasal cavity in areas where miniscrews are usually inserted using cone beam computed tomography (CBCT). DESIGN: Retrospective, cross-sectional. SETTING: Department of maxillofacial radiology in a Saudi dental school. PATIENTS AND METHODS: Using CBCT images, we measured the distance between the maxillary sinus and nasal cavity to the palatal bone, buccal intra-radicular and infrazygomatic crest areas. Mean values (SD) were compared at various locations, including by gender, and correlation with age was calculated. MAIN OUTCOME MEASURE: Mean bone thickness at commonly used sites for orthodontic miniscrew placements in the maxilla. Secondary outcome was the insertion angle in the infrazygomatic crest area. SAMPLE SIZE: CBCT images of 100 patients (50 males and 50 females). RESULTS: The mean (standard deviation) age for the sample was 25.4 (6.5) years with no significant difference between males and females. In the palate, the distance to the nasal cavity and maxillary sinus was greater anteriorly and decreased significantly posteriorly (P<.001). Buccally, the interdental bone depth was significantly greater between the second premolar and first molar (11.96 mm) compared to between the central and lateral incisors (7.53 mm, P<.001). The mean bone thickness of the infrazygomatic crest area at a 45 degrees insertion angle was 4.94 mm compared to 3.90 at a 70 degrees insertion angle (P<.001). No correlation was found between age and bone thickness. CONCLUSION: The distance to the nasal cavity and maxillary sinus was greater in the anterior than posterior areas. There is minimal risk of injuring the maxillary sinus or nasal cavity using the buccal approach. Caution is needed when placing miniscrews in the infrazygomatic crest area. LIMITATIONS: Cross-sectional study from one center; hence, findings cannot be generalized to other populations.
引用
收藏
页码:330 / 337
页数:8
相关论文
共 45 条
  • [1] Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography
    Abbassy, Mona A.
    Sabban, Hanady M.
    Hassan, Ali H.
    Zawawi, Khalid H.
    [J]. SAUDI MEDICAL JOURNAL, 2015, 36 (11) : 1336 - 1341
  • [2] Long-term durability of orthodontic mini-implants
    Abbassy, Mona Aly
    Bakry, Ahmed Samir
    Zawawi, Khalid Hashim
    Hassan, Ali Habib
    [J]. ODONTOLOGY, 2018, 106 (02) : 208 - 214
  • [3] Al-Fraidi Ahmad Ali, 2010, J Can Dent Assoc, V76, pa9
  • [4] The use of mini-implants in en masse retraction for the treatment of bimaxillary dentoalveolar protrusion
    Aljhani, Ali
    Zawawi, Khalid H.
    [J]. SAUDI DENTAL JOURNAL, 2010, 22 (01) : 35 - 39
  • [5] American Academy of O Maxillofacial R, 2013, ORAL SURG ORAL MED O, V116, P238
  • [6] In-vitro impact of insertion angle on primary stability of miniscrews
    Araghbidikashani, Mehdi
    Golshah, Amin
    Nikkerdar, Nafiseh
    Rezaei, Majid
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (03) : 436 - 443
  • [7] Miniscrew biomechanics: Guidelines for the use of rigid indirect anchorage mechanics
    Baumgaertel, Sebastian
    Jones, Clark L.
    Unal, Mustafa
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (03) : 413 - 419
  • [8] Cortical bone thickness and bone depth of the posterior palatal alveolar process for mini-implant insertion in adults
    Baumgaertel, Sebastian
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) : 806 - 811
  • [9] Buccal cortical bone thickness for mini-implant placement
    Baumgaertel, Sebastian
    Hans, Mark G.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) : 230 - 235
  • [10] Quantitative investigation of palatal bone depth and cortical bone thickness for mini-implant placement in adults
    Baumgaertel, Sebastian
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 104 - 108