A New Single-Ended Fault-Location Scheme for Utilization in an Integrated Power System

被引:43
作者
Jia, Ke [1 ]
Thomas, David [1 ]
Sumner, Mark [1 ]
机构
[1] Univ Nottingham, Dept Elect Engn, Nottingham NG7 2RD, England
关键词
Fault location; single ended; transients; IMPEDANCE MEASUREMENT; NETWORKS; QUALITY;
D O I
10.1109/TPWRD.2012.2215346
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new single-ended fault-location method based on impedance measurement for distribution power systems. The algorithm, which involves an iteration estimate of the prefault voltage and least square curve fitting, provides fast and accurate fault location by comparing the calculated line reactance between the fault point and the measurement point with the known line reactance. The fault voltage and current transients measured at the measurement point are transformed into the frequency domain by the fast Fourier transform (FFT), and in order to increase the speed and accuracy of fault location, only high-frequency transient information was used. The advantages of this new method, compared with traditional single-end impedance measurement fault-location algorithms (distance protection scheme), are demonstrated both through simulation and laboratory measurements.
引用
收藏
页码:38 / 46
页数:9
相关论文
共 18 条
[1]  
[Anonymous], ELECT POWER SYST PRO
[2]   Integrated Use of Time-Frequency Wavelet Decompositions for Fault Location in Distribution Networks: Theory and Experimental Validation [J].
Borghetti, A. ;
Bosetti, M. ;
Nucci, C. A. ;
Paolone, M. ;
Abur, A. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :3139-3146
[3]   Continuous-wavelet transform for fault location in distribution power networks: Definition of mother wavelets inferred from fault originated transients [J].
Borghetti, Alberto ;
Bosetti, Mauro ;
Di Silvestro, Mauro ;
Nucci, Carlo Alberto ;
Paolone, Mario .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) :380-388
[4]   WHAT IS FAST FOURIER TRANSFORM [J].
COCHRAN, WT ;
COOLEY, JW ;
FAVIN, DL ;
HELMS, HD ;
KAENEL, RA ;
LANG, WW ;
MALING, GC ;
NELSON, DE ;
RADER, CM ;
WELCH, PD .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1967, 55 (10) :1664-+
[5]  
Coggins D. P., 2008, P I EL ENG DEV POW S, p579
[6]   An iterative two-terminal fault-location method based on unsynchronized phasors [J].
Dalcastagne, Andre Luis ;
Noceti Filho, Sidnei ;
Zuern, Hans Helmut ;
Seara, Rui .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) :2318-2329
[7]  
Das J.C., 2002, POWER SYSTEM ANAL SH, DOI DOI 10.1201/9780203908952
[8]  
Di Piazza MC, 2000, INT C HARMON QUAL PO, P520, DOI 10.1109/ICHQP.2000.897733
[9]  
Emadi A., 2004, VEHICULAR ELECT POWE, P15
[10]  
Huang J, 2006, IEEE IND APPLIC SOC, P300