Improved kinetic model for the transcutaneous measurement of glomerular filtration rate in experimental animals

被引:37
|
作者
Friedemann, Jochen [1 ,2 ,3 ,4 ]
Heinrich, Ralf [5 ]
Shulhevich, Yury [1 ,2 ,3 ,4 ]
Raedle, Matthias [1 ,2 ,3 ]
William-Olsson, Lena [6 ]
Pill, Johannes [4 ]
Schock-Kusch, Daniel [1 ,2 ,3 ,4 ]
机构
[1] Mannheim Univ Appl Sci, Inst Proc Control & Innovat Energy Convers PI, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[2] Heidelberg Univ, Inst Med Technol, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[3] Univ Appl Sci Mannheim, Paul Wittsack Str 10, D-68163 Mannheim, Baden Wuerttemb, Germany
[4] Mannheim Pharma & Diagnost GmbH, Mannheim, Germany
[5] Freudenberg New Technol SE, Weinheim, Germany
[6] AstraZeneca R&D, Biosci CKD Gothenburg, Molndal, Sweden
关键词
FITC-sinistrin; glomerular filtration rate; transcutaneous; FITC-SINISTRIN; RENAL-FUNCTION;
D O I
10.1016/j.kint.2016.07.024
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Transcutaneous measurement of the glomerular filtration rate ((t)GFR) is now frequently used in animal studies. (t)GFR allows consecutive measurements on the same animal, including multiple measurements on a daily basis, because no blood sampling is required. Here we derive and validate a novel kinetic model for the description of transcutaneously measured FITC-Sinistrin excretion kinetics. In contrast to standard 1- to 3-compartment models, our model covers the complete kinetic, including injection and distribution of the tracer in the plasma compartment. Because the model describes the complete progression of the measurement, it allows further refinement by correcting for baseline shifts observed occasionally during measurement. Possible reasons for shifts in the background signal include photo bleaching of the skin, autofluorescence, changes of physiological state of the animals during the measurements, or effects arising from the attachment of the measurement device. Using the new 3-compartment kinetic model with modulated baseline ((t)GFR(3cp.b.m)), (t)GFR measurements in rats can reach comparable precision as those from GFR measurements assessed using a gold standard technique based on constant infusion of a tracer. Moreover, the variability of simultaneous (parallel) measurements, as well as repeated (t)GFR measurements in the same animals, showed higher precision when (t)GFR(3cp.b.m) was compared with the 1 compartment (t)GFR(1cp) model.
引用
收藏
页码:1377 / 1385
页数:9
相关论文
共 50 条
  • [41] Post-kidney donation glomerular filtration rate measurement and estimation
    Lujan, Pablo
    Chiurchiu, Carlos
    Capra, Raul
    de Arteaga, Javier
    de la Fuente, Jorge
    Walter Douthat, Y.
    NEFROLOGIA, 2021, 41 (02): : 191 - 199
  • [42] GLOMERULAR-FILTRATION RATE MEASUREMENT - A NEGLECTED TEST IN UROLOGICAL PRACTICE
    BROWN, SCW
    OREILLY, PH
    BRITISH JOURNAL OF UROLOGY, 1995, 75 (03): : 296 - 300
  • [43] The kinetic estimated glomerular filtration rate ratio predicts acute kidney injury
    Christiadi, Daniel
    Erlich, Jonathan
    Levy, Melissa
    Herath, Sanjeeva
    Qian, Jennifer
    Boardman, Sally
    Campbell, Craig
    Kotwal, Sradha
    Horvath, Andrea R.
    Endre, Zoltan
    NEPHROLOGY, 2021, 26 (10) : 782 - 789
  • [44] New Model for Estimating Glomerular Filtration Rate in Patients With Cancer
    Janowitz, Tobias
    Williams, Edward H.
    Marshall, Andrea
    Ainsworth, Nicola
    Thomas, Peter B.
    Sammut, Stephen J.
    Shepherd, Scott
    White, Jeff
    Mark, Patrick B.
    Lynch, Andy G.
    Jodrell, Duncan I.
    Tavare, Simon
    Earl, Helena
    JOURNAL OF CLINICAL ONCOLOGY, 2017, 35 (24) : 2798 - +
  • [45] Improved measurement of the glomerular filtration rate from Tc-99m DTPA scintigraphy in patients following nephrectomy
    Yong-il Kim
    Seunggyun Ha
    Young So
    Won Woo Lee
    Seok-Soo Byun
    Sang Eun Kim
    European Radiology, 2014, 24 : 413 - 422
  • [46] Measurement of glomerular filtration rate by low-dose iopromide plasma clearance
    Hackstein, N
    Wiegand, C
    Langheinrich, AC
    Rau, WS
    ACTA RADIOLOGICA, 2003, 44 (02) : 162 - 165
  • [47] Suitability of a simplified technique based on iohexol for decentralized measurement of glomerular filtration rate
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2008, 42 (05): : 472 - 480
  • [48] Kidney Function: Glomerular Filtration Rate Measurement with MR Renography in Patients with Cirrhosis
    Vivier, Pierre-Hugues
    Storey, Pippa
    Rusinek, Henry
    Zhang, Jeff L.
    Yamamoto, Akira
    Tantillo, Kristopher
    Khan, Umer
    Lim, Ruth P.
    Babb, James S.
    John, Devon
    Teperman, Lewis W.
    Chandarana, Hersh
    Friedman, Kent
    Benstein, Judith A.
    Skolnik, Edward Y.
    Lee, Vivian S.
    RADIOLOGY, 2011, 259 (02) : 462 - 470
  • [49] Kinetic estimated glomerular filtration rate and acute kidney injury in cardiac surgery patients
    Seelhammer, Troy G.
    Maile, Michael D.
    Heung, Michael
    Haft, Jonathan W.
    Jewell, Elizabeth S.
    Engoren, Milo
    JOURNAL OF CRITICAL CARE, 2016, 31 (01) : 249 - 254
  • [50] Development of formulae for accurate measurement of the glomerular filtration rate by renal dynamic imaging
    Li, Qian
    Zhang, Chun-li
    Fu, Zhan-li
    Wang, Rong-fu
    Ma, Ying-chun
    Zuo, Li
    NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (05) : 407 - 413