New calibration and evaluation method for PET scanners using point-like radioactive sources

被引:0
|
作者
Hasegawa, Tomoyuki [1 ]
Oda, Keiichi [2 ]
Sato, Yasushi [3 ]
Wada, Yasuhiro [4 ]
Yamada, Takahiro [5 ]
Yoshida, Eiji [6 ]
Murayama, Hideo [6 ]
Saito, Kyoko [7 ]
Takeda, Toru [7 ]
Kikuchi, Kei [8 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Minami Ku, Kitasato 1-15-1, Sagamihara, Kanagawa 2520373, Japan
[2] Tokyo Metropolitan Inst Gerontol, Ctr Med, Tokyo, Japan
[3] Adv Ind Sci & Technol, Ibaraki, Japan
[4] RIKEN Ctr Mol Imaging Sci, Hyogo, Japan
[5] Japan Radiolog Assoc, Tokyo, Japan
[6] Natl Inst Radiolog Sci, Chiba, Japan
[7] Kitasato Univ, Sch Allied Hlth Sci, Kanagawa, Japan
[8] Kitasato Univ Hosp, Div Radiol, Kanagawa, Japan
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Objective: In order to improve the convenience and reliability of the calibration procedure with respect to the quantitative aspects of PET scanners, we have been developing new methods that rely on the use of point-like radioactive sources. The aim of this study is to report the results of the application of the proposed method for obtaining the cross-calibration factors (CCFs) of a clinical PET scanner for the first time. Methods: A Na-22 point-like source was moved in the axial direction to cover the axial field-of-view (FOV) of a commercial PET scanner, SET-2400W (Shimadzu). From reconstructed images, saturated regions-of-interest (ROI) values were used to calculate the CCFs that were defined slice by slice. Results: It was possible to obtain CCFs that were practically equivalent to those obtained by the standard method with cylindrical water phantoms. The variations in the CCFs obtained over about a half-year were well reproduced by the proposed method. Conclusion: The proposed calibration method, which is based on the use of a point-like radioactive source, is useful for determining CCFs and their variations for a clinical PET scanner.
引用
收藏
页码:2929 / +
页数:2
相关论文
共 50 条
  • [31] Traceable point-like 68Ge/68Ga source with a spherically symmetric positron absorber for PET scanners
    Tomoyuki Hasegawa
    Mio Okamoto
    Takahiro Yamada
    Hidetake Ishizu
    Takahiro Mikamoto
    Yasushi Sato
    Hiroki Miyatake
    Kei Kikuchi
    Yusuke Inoue
    Radiological Physics and Technology, 2020, 13 : 170 - 176
  • [32] Algorithms to search for point-like neutrinos sources with the ANTARES telescope
    Aguilar, J. A.
    Proceedings of the 29th International Cosmic Ray Conference, Vol 5: OG 2.5, 2.6 & 2.7, 2005, : 83 - 86
  • [33] Search for Point-Like TeV Sources in the Large Magellanic Cloud
    Komin, Nukri
    Haupt, Maria
    36TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2019, 2021,
  • [34] A METHOD FOR TIME CALIBRATION OF PET SYSTEMS USING FIXED β+ RADIOACTIVE SOURCE
    Dulski, K.
    Silarski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 195 - 200
  • [35] Designing two freeform surfaces with Monge-Ampere equation method for point-like sources
    Wu, Rengmao
    Chang, Shengqian
    Ding, Zhanghao
    Zheng, Zhenrong
    ILLUMINATION OPTICS V, 2018, 10693
  • [36] Evaluation of spatial dependence of point spread function-based PET reconstruction using a traceable point-like 22Na source
    Murata, Taisuke
    Miwa, Kenta
    Miyaji, Noriaki
    Wagatsuma, Kei
    Hasegawa, Tomoyuki
    Oda, Keiichi
    Umeda, Takuro
    Iimori, Takashi
    Masuda, Yoshitada
    Terauchi, Takashi
    Koizumi, Mitsuru
    EJNMMI PHYSICS, 2016, 3 (01):
  • [37] Semi-automated plug-in QC/QA tool for analyzing PET images obtained using traceable point-like sources
    Takahashi, Kentaro
    Okamoto, Mio
    Hasegawa, Tomoyuki
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [38] Evaluation of spatial dependence of point spread function-based PET reconstruction using a traceable point-like 22Na source
    Taisuke Murata
    Kenta Miwa
    Noriaki Miyaji
    Kei Wagatsuma
    Tomoyuki Hasegawa
    Keiichi Oda
    Takuro Umeda
    Takashi Iimori
    Yoshitada Masuda
    Takashi Terauchi
    Mitsuru Koizumi
    EJNMMI Physics, 3
  • [39] Clusters of black holes as point-like gamma-ray sources
    Belotsky, K. M.
    Berkov, A. V.
    Kirillov, A. A.
    Rubin, S. G.
    ASTROPARTICLE PHYSICS, 2011, 35 (01) : 28 - 32
  • [40] Marine bacterial organisation around point-like sources of amino acids
    Barbara, GM
    Mitchell, JG
    FEMS MICROBIOLOGY ECOLOGY, 2003, 43 (01) : 99 - 109