New calibration and evaluation method for PET scanners using point-like radioactive sources

被引:0
|
作者
Hasegawa, Tomoyuki [1 ]
Oda, Keiichi [2 ]
Sato, Yasushi [3 ]
Wada, Yasuhiro [4 ]
Yamada, Takahiro [5 ]
Yoshida, Eiji [6 ]
Murayama, Hideo [6 ]
Saito, Kyoko [7 ]
Takeda, Toru [7 ]
Kikuchi, Kei [8 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Minami Ku, Kitasato 1-15-1, Sagamihara, Kanagawa 2520373, Japan
[2] Tokyo Metropolitan Inst Gerontol, Ctr Med, Tokyo, Japan
[3] Adv Ind Sci & Technol, Ibaraki, Japan
[4] RIKEN Ctr Mol Imaging Sci, Hyogo, Japan
[5] Japan Radiolog Assoc, Tokyo, Japan
[6] Natl Inst Radiolog Sci, Chiba, Japan
[7] Kitasato Univ, Sch Allied Hlth Sci, Kanagawa, Japan
[8] Kitasato Univ Hosp, Div Radiol, Kanagawa, Japan
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Objective: In order to improve the convenience and reliability of the calibration procedure with respect to the quantitative aspects of PET scanners, we have been developing new methods that rely on the use of point-like radioactive sources. The aim of this study is to report the results of the application of the proposed method for obtaining the cross-calibration factors (CCFs) of a clinical PET scanner for the first time. Methods: A Na-22 point-like source was moved in the axial direction to cover the axial field-of-view (FOV) of a commercial PET scanner, SET-2400W (Shimadzu). From reconstructed images, saturated regions-of-interest (ROI) values were used to calculate the CCFs that were defined slice by slice. Results: It was possible to obtain CCFs that were practically equivalent to those obtained by the standard method with cylindrical water phantoms. The variations in the CCFs obtained over about a half-year were well reproduced by the proposed method. Conclusion: The proposed calibration method, which is based on the use of a point-like radioactive source, is useful for determining CCFs and their variations for a clinical PET scanner.
引用
收藏
页码:2929 / +
页数:2
相关论文
共 50 条
  • [1] Evaluation and Calibration of PET Scanners with a Specially Designed Point-like Radioactive Source
    Hasegawa, Tomoyuki
    Sato, Yasushi
    Yoshida, Eiji
    Yamada, Takahiro
    Oda, Keiichi
    Wada, Yasuhiro
    Yamaya, Taiga
    Murayama, Hideo
    Takeda, Toni
    Saito, Kyoko
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3630 - +
  • [2] Point-like radioactive source with multiple absorber capsules for evaluating PET scanners
    Hasegawa, Tomoyuki
    Yoshida, Eiji
    Sato, Yasushi
    Oda, Keiichi
    Wada, Yasuhiro
    Yamada, Takahiro
    Yamaya, Taiga
    Murayama, Hideo
    Saito, Kyoko
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (05) : 427 - 432
  • [3] Point-like radioactive source with multiple absorber capsules for evaluating PET scanners
    Tomoyuki Hasegawa
    Eiji Yoshida
    Yasushi Sato
    Keiichi Oda
    Yasuhiro Wada
    Takahiro Yamada
    Taiga Yamaya
    Hideo Murayama
    Kyoko Saito
    Annals of Nuclear Medicine, 2010, 24 : 427 - 432
  • [4] A practical method of determining cross-calibration factors of PET scanners by moving a point-like 22Na radioactive source
    Hasegawa, Tomoyuki
    Oda, Keiichi
    Wada, Yasuhiro
    Sato, Yasushi
    Yamada, Takahiro
    Yoshida, Eiji
    Murayama, Hideo
    Saito, Kyoko
    Takeda, Tohoru
    Kikuchi, Kei
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (09) : 655 - 661
  • [5] A practical method of determining cross-calibration factors of PET scanners by moving a point-like 22Na radioactive source
    Tomoyuki Hasegawa
    Keiichi Oda
    Yasuhiro Wada
    Yasushi Sato
    Takahiro Yamada
    Eiji Yoshida
    Hideo Murayama
    Kyoko Saito
    Tohoru Takeda
    Kei Kikuchi
    Annals of Nuclear Medicine, 2010, 24 : 655 - 661
  • [6] Validation of novel calibration scheme with traceable point-like 22Na sources on six types of PET scanners
    Tomoyuki Hasegawa
    Keiichi Oda
    Yasuhiro Wada
    Toshiaki Sasaki
    Yasushi Sato
    Takahiro Yamada
    Mikio Matsumoto
    Hideo Murayama
    Kei Kikuchi
    Hiroki Miyatake
    Yutaka Abe
    Kenta Miwa
    Kenta Akimoto
    Kei Wagatsuma
    Annals of Nuclear Medicine, 2013, 27 : 346 - 354
  • [7] Validation of novel calibration scheme with traceable point-like 22Na sources on six types of PET scanners
    Hasegawa, Tomoyuki
    Oda, Keiichi
    Wada, Yasuhiro
    Sasaki, Toshiaki
    Sato, Yasushi
    Yamada, Takahiro
    Matsumoto, Mikio
    Murayama, Hideo
    Kikuchi, Kei
    Miyatake, Hiroki
    Abe, Yutaka
    Miwa, Kenta
    Akimoto, Kenta
    Wagatsuma, Kei
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (04) : 346 - 354
  • [8] Calibration of PET scanners with a new traceable point-like Ge68/Ga68 source
    Hasegawa, Tomoyuki
    Oda, Keiichi
    Wada, Yasuhiro
    Sato, Yasushi
    Murayama, Hideo
    Yamada, Takahiro
    Matsumoto, Mikio
    Igarashi, Masafumi
    Iryo, Jun
    Kamitaka, Hiroaki
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2880 - 2882
  • [9] Application of novel calibration scheme based on traceable point-like 22Na sources to various types of PET scanners
    Hasegawa, Tomoyuki
    Oda, Keiichi
    Wada, Yasuhiro
    Sato, Yasushi
    Yamada, Takahiro
    Matsumoto, Mikio
    Murayama, Hideo
    Takeda, Toru
    Sasaki, Toshiaki
    Kikuchi, Kei
    Abe, Yutaka
    Miyatake, Hiroki
    Miwa, Kenta
    Akimoto, Kenta
    Wagatsuma, Kei
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2873 - 2875
  • [10] Semi-quantitative and simulation analyses of effects of γ rays on determination of calibration factors of PET scanners with point-like 22Na sources
    Hasegawa, Tomoyuki
    Sato, Yasushi
    Oda, Keiichi
    Wada, Yasuhiro
    Murayama, Hideo
    Yamada, Takahiro
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18): : 6031 - 6045