Bioimpedance Measurement of Knee Injuries Using Bipolar Electrode Configuration

被引:6
|
作者
Ye, Xuanjie [1 ]
Wu, Lexi [2 ]
Mao, Kaining [1 ]
Feng, Yiwei [1 ]
Li, Jiajun [1 ]
Ning, Lei [3 ]
Chen, Jie [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[2] Zhejiang Univ, Sch Med, Hangzhou 310030, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Orthopaed Surg, Med Coll, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Bioimpedance; Electrodes; Injuries; Knee; Current measurement; Biomedical measurement; Impedance; bipolar electrode configuration; knee injuries; machine learning; portable device; BIOELECTRICAL-IMPEDANCE; ELECTRICAL BIOIMPEDANCE; DRY ELECTRODES; EDEMA; BODY; INFLAMMATION; LYMPHEDEMA; MANAGEMENT; DIAGNOSIS; SEVERITY;
D O I
10.1109/TBCAS.2022.3200355
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, there is no suitable solution for the point-of-care diagnosis of knee injuries. A potential portable and low-cost technique for accessing and monitoring knee injuries is bioimpedance measurement. This study validated the feasibility of the bipolar electrode configuration for knee bioimpedance measurement with two electrodes placed on a fixed pair of knee acupuncture locations called Xiyan. Then, the study collected 76 valid samples to investigate the relationship between bioimpedance and knee injuries, among whom 39 patients have unilateral knee injuries, and 37 individuals have healthy knees. The self-contrast results indicated that knee injuries caused a reduction of bioimpedance of the knee by about 5% on average, which was detectable at around 100 kHz (p approximate to 0.001). Furthermore, the results analyzed by principal component analysis and support vector machines show that the detection sensitivity can reach 87.18% using the leave-one-out cross-validation. We also proposed a low-cost and portable bioimpedance measurement device that meets the needs for measuring knee joint bioimpedance.
引用
收藏
页码:962 / 971
页数:10
相关论文
共 50 条
  • [31] Measurement of Rotor Clearance Using a Dual-Electrode Electrostatic Sensor
    Liu, Xuanda
    Yan, Yong
    Hu, Yonghui
    Wang, Lijuan
    IEEE SENSORS JOURNAL, 2025, 25 (05) : 8043 - 8052
  • [32] Current measurement methods in irradiated metal-dielectric systems with homogeneous and heterogeneous dielectrics having complex electrode configuration
    Makeev, S.N.
    Posysaev, E.I.
    Filatov, N.I.
    Shurygin, A.V.
    Elektrotekhnika, 1991, (08): : 63 - 68
  • [33] Lung ventilation monitoring by electrical bioimpedance technique using three different 4-electrode thoracic configurations: Variability of calibration equations
    Balleza-Ordaz, M.
    Estrella-Ceron, R.
    Romero-Muniz, T.
    Vargas-Luna, M.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 47 : 401 - 412
  • [34] Knee Angle Estimation with Dynamic Calibration Using Inertial Measurement Units for Running
    Rhudy, Matthew B.
    Mahoney, Joseph M.
    Altman-Singles, Allison R.
    SENSORS, 2024, 24 (02)
  • [35] In vivo measurement of human knee and hip dynamics using MIMO system identification
    Koopman, B.
    van Asseldonk, E. H. F.
    van der Kooij, H.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3426 - 3429
  • [36] Acute Single-Stage Reconstruction of Multiligament Knee Injuries Using the Ligament Advanced Reinforcement System
    Tao, Jie
    Li, Xia
    Zhou, Zihui
    Zhu, Zhenan
    MEDICAL PRINCIPLES AND PRACTICE, 2013, 22 (04) : 373 - 378
  • [37] Electrical impedance spectroscopy measurements using a four-electrode configuration improve on-line monitoring of cell concentration in adherent animal cell cultures
    Sarro, E.
    Lecina, M.
    Fontova, A.
    Sola, C.
    Godia, F.
    Cairo, J. J.
    Bragos, R.
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01) : 257 - 263
  • [38] Knee joint cartilage injuries using magnetic resonance: advantages of using 3.0 Tesla proton density-weighted sequences
    Crespo Villalba, Francisco Jose
    IMAGEN DIAGNOSTICA, 2011, 2 (02): : 53 - 58
  • [39] Multi-frequency and Multi-segment Bio-impedance Measurement Using Tetra-polar Electrode Setup
    Kamat, D. K.
    Patil, P. M.
    PROCEEDINGS OF 2016 2ND INTERNATIONAL CONFERENCE ON CONTROL SCIENCE AND SYSTEMS ENGINEERING (ICCSSE), 2016, : 190 - 194
  • [40] Novel Measurement Technique for Knee Joint Laxities Using Polymeric Capacitive Strain Gauges
    Zens, M.
    Ruhhammer, J.
    Goldschmidtboeing, F.
    Woias, P.
    Mayr, H. O.
    Niemeyer, P.
    Bernstein, A.
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 237 - 242