Bioimpedance Measurement of Knee Injuries Using Bipolar Electrode Configuration

被引:6
|
作者
Ye, Xuanjie [1 ]
Wu, Lexi [2 ]
Mao, Kaining [1 ]
Feng, Yiwei [1 ]
Li, Jiajun [1 ]
Ning, Lei [3 ]
Chen, Jie [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[2] Zhejiang Univ, Sch Med, Hangzhou 310030, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Orthopaed Surg, Med Coll, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Bioimpedance; Electrodes; Injuries; Knee; Current measurement; Biomedical measurement; Impedance; bipolar electrode configuration; knee injuries; machine learning; portable device; BIOELECTRICAL-IMPEDANCE; ELECTRICAL BIOIMPEDANCE; DRY ELECTRODES; EDEMA; BODY; INFLAMMATION; LYMPHEDEMA; MANAGEMENT; DIAGNOSIS; SEVERITY;
D O I
10.1109/TBCAS.2022.3200355
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, there is no suitable solution for the point-of-care diagnosis of knee injuries. A potential portable and low-cost technique for accessing and monitoring knee injuries is bioimpedance measurement. This study validated the feasibility of the bipolar electrode configuration for knee bioimpedance measurement with two electrodes placed on a fixed pair of knee acupuncture locations called Xiyan. Then, the study collected 76 valid samples to investigate the relationship between bioimpedance and knee injuries, among whom 39 patients have unilateral knee injuries, and 37 individuals have healthy knees. The self-contrast results indicated that knee injuries caused a reduction of bioimpedance of the knee by about 5% on average, which was detectable at around 100 kHz (p approximate to 0.001). Furthermore, the results analyzed by principal component analysis and support vector machines show that the detection sensitivity can reach 87.18% using the leave-one-out cross-validation. We also proposed a low-cost and portable bioimpedance measurement device that meets the needs for measuring knee joint bioimpedance.
引用
收藏
页码:962 / 971
页数:10
相关论文
共 50 条
  • [1] Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy
    Edwick, Dale O.
    Hince, Dana A.
    Rawlins, Jeremy M.
    Wood, Fiona M.
    Edgar, Dale W.
    LYMPHATIC RESEARCH AND BIOLOGY, 2020, 18 (06) : 560 - 571
  • [2] Four electrode embedded bioimpedance measurement system
    Margo, Cedric
    Katrib, Juliano
    Nadi, Mustapha
    Rouane, Amar
    2013 IEEE FAIBLE TENSION FAIBLE CONSOMMATION (FTFC), 2013,
  • [3] BIOIMPEDANCE ACTIVE ELECTRODE FOR IN-VIVO MEASUREMENT
    RECORD, PM
    ROSELL, X
    RIGAUD, B
    RIU, PJCI
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (06) : 683 - 685
  • [4] Modelling Approach for Assessment of Electrode Configuration and Placement in Bioimpedance Measurements of Skin Irritation
    Koppa, S.
    Savolainen, V.
    Hyttinen, J.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 1238 - 1241
  • [5] Bioimpedance Measurement Using Mixed-Signal Embedded System
    Jairo Cabrera-Lopez, John
    Velasco-Medina, Jaime
    Rodriguez Denis, Ernesto
    Briceno Calderon, Juan Felipe
    Gomez Guevara, Oscar Julian
    2016 IEEE 7TH LATIN AMERICAN SYMPOSIUM ON CIRCUITS & SYSTEMS (LASCAS), 2016, : 335 - 338
  • [6] Pulse Transit Time Measurement Using Bioimpedance
    Pires, Andrei L. A.
    Souza, Marcio N.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL 1, 2019, 70 (01): : 531 - 535
  • [7] Evaluation of Two-Electrode System Configurations for Forearm Arteries Bioimpedance Measurement
    Metshein, Margus
    Pesti, Ksenija
    Lapsa, Didzis
    Annus, Paul
    Janeliukstis, Rims
    Elsts, Atis
    Martens, Olev
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [8] Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis
    Yang, Eun Mi
    Park, Eujin
    Ahn, Yo Han
    Choi, Hyun Jin
    Kang, Hee Gyung
    Cheong, Hae Il
    Ha, Il Soo
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2017, 32 (11) : 1828 - 1834
  • [9] Measurement of body fat using leg to leg bioimpedance
    Sung, RYT
    Lau, P
    Yu, CW
    Lam, PKW
    Nelson, EAS
    ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 85 (03) : 263 - 267
  • [10] Variability of Cole-model bioimpedance parameters using magnitude-only measurements of apples from a two-electrode configuration