The accuracy of computed tomography-based linear measurements of human femora and titanium stem

被引:15
|
作者
Feng, ZD
Ziv, I
Rho, J
机构
[1] SUNY BUFFALO,DEPT ORTHOPAED SURG,BUFFALO,NY 14214
[2] DEPT VET AFFAIRS MED CTR,BUFFALO,NY
关键词
computed tomography; hip arthroplasty; femur; titanium stem; image analysis; profile window; Half-maximum height;
D O I
10.1097/00004424-199606000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS. Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned, Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique, A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images, The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS. Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%), The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS. The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem, The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [21] Advances in computed tomography-based prognostic methods for intracerebral hemorrhage
    Huang, Xiaoyu
    Wang, Dan
    Li, Shenglin
    Zhou, Qing
    Zhou, Junlin
    NEUROSURGICAL REVIEW, 2022, 45 (03) : 2041 - 2050
  • [22] Computed Tomography-Based Humeral Templating for Uncemented Elbow Arthroplasty
    Kohls, Morgan R.
    Robertson, Emerald D.
    Beckwitt, Colin H.
    Ghodadra, Anish A.
    Kaufmann, Robert A.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023,
  • [23] Advances in computed tomography-based prognostic methods for intracerebral hemorrhage
    Xiaoyu Huang
    Dan Wang
    Shenglin Li
    Qing Zhou
    Junlin Zhou
    Neurosurgical Review, 2022, 45 : 2041 - 2050
  • [24] PREDICTIVE VALUE OF COMPUTED TOMOGRAPHY-BASED DIAGNOSIS OF INTRACRANIAL TUBERCULOMAS
    SELVAPANDIAN, S
    RAJSHEKHAR, V
    CHANDY, MJ
    IDIKULA, J
    NEUROSURGERY, 1994, 35 (05) : 845 - 850
  • [25] Accuracy of Subaxial Cervical Pedicle Screw Placement Using Direct Visualization Versus Computed Tomography-Based Navigation
    Farber, S. Harrison
    Godzik, Jakub
    Hlubek, Randall J.
    Zhou, James J.
    Walker, Corey T.
    Kakarla, U. Kumar
    Uribe, Juan S.
    Turner, Jay D.
    CLINICAL SPINE SURGERY, 2022, 35 (01): : E104 - E110
  • [26] A novel computed tomography-based three-column MLP classification of intertrochanteric fracture
    Jiang, Qi-Long
    Li, Yan
    Bai, Xin-Wen
    Deng, Yu
    Hong, Hao
    Li, Jun
    Cao, Yong
    Peng, Xiao-Yu
    JOURNAL OF MEDICAL INVESTIGATION, 2023, 70 (3-4) : 524 - 529
  • [27] Evaluation of sarcopenia-associated survival in breast cancer with computed tomography-based pectoral muscle area measurements
    Kuzan, Beyza Nur
    Majidova, Nargiz
    Ilgin, Can
    Arslan Kar, Hulya
    Kursun, Meltem
    Ozguven, Salih
    Bayoglu, Ibrahim Vedat
    Bugdayci, Onur
    Yumuk, Perran Fulden
    Kaya, Handan
    MARMARA MEDICAL JOURNAL, 2024, 37 (02): : 178 - 184
  • [28] Prediction of Malignant Middle Cerebral Artery Infarction Using Computed Tomography-Based Intracranial Volume Reserve Measurements
    Minnerup, Jens
    Wersching, Heike
    Ringelstein, E. Bernd
    Heindel, Walter
    Niederstadt, Thomas
    Schilling, Matthias
    Schaebitz, Wolf-Ruediger
    Kemmling, Andre
    STROKE, 2011, 42 (12) : 3403 - U138
  • [29] The Accuracy of Computed Tomography-Based, Three-Dimensional Implant Planning in Robotic-Assisted Total Knee Arthroplasty
    Marchand, Kevin B.
    Salem, Hytham S.
    Mathew, Kevin K.
    Harwin, Steven F.
    Mont, Michael A.
    Marchand, Robert C.
    JOURNAL OF KNEE SURGERY, 2022, 35 (14) : 1587 - 1594
  • [30] Retropharyngeal lymphadenopathy in patients with nasopharyngeal carcinoma - A computed tomography-based study
    Chua, DTT
    Sham, JST
    Kwong, DLW
    Au, GKH
    Choy, DTK
    CANCER, 1997, 79 (05) : 869 - 877