The accuracy of computed tomography-based linear measurements of human femora and titanium stem

被引:15
|
作者
Feng, ZD
Ziv, I
Rho, J
机构
[1] SUNY BUFFALO,DEPT ORTHOPAED SURG,BUFFALO,NY 14214
[2] DEPT VET AFFAIRS MED CTR,BUFFALO,NY
关键词
computed tomography; hip arthroplasty; femur; titanium stem; image analysis; profile window; Half-maximum height;
D O I
10.1097/00004424-199606000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS. Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned, Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique, A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images, The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS. Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%), The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS. The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem, The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [1] Clinical accuracy and precision of hip resurfacing arthroplasty using computed tomography-based navigation
    Sato, Ryuichi
    Takao, Masaki
    Hamada, Hidetoshi
    Sakai, Takashi
    Marumo, Keishi
    Sugano, Nobuhiko
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (08) : 1807 - 1814
  • [2] Computed tomography-based measurements of normative liver and spleen volumes in children
    Alves, Vinicius de Padua V.
    Dillman, Jonathan R.
    Somasundaram, Elanchezhian
    Taylor, Zachary P.
    Brady, Samuel L.
    Zhang, Bin
    Trout, Andrew T.
    PEDIATRIC RADIOLOGY, 2023, 53 (03) : 378 - 386
  • [3] Computed tomography-based measurements of normative liver and spleen volumes in children
    Vinicius de Padua V. Alves
    Jonathan R. Dillman
    Elanchezhian Somasundaram
    Zachary P. Taylor
    Samuel L. Brady
    Bin Zhang
    Andrew T. Trout
    Pediatric Radiology, 2023, 53 : 378 - 386
  • [4] Clinical accuracy and precision of hip resurfacing arthroplasty using computed tomography-based navigation
    Ryuichi Sato
    Masaki Takao
    Hidetoshi Hamada
    Takashi Sakai
    Keishi Marumo
    Nobuhiko Sugano
    International Orthopaedics, 2019, 43 : 1807 - 1814
  • [5] Accuracy of computer navigation in total knee arthroplasty: A prospective computed tomography-based study
    Hannan, Richard
    Free, Matthew
    Arora, Varun
    Harle, Robin
    Harvie, Paul
    MEDICAL ENGINEERING & PHYSICS, 2020, 79 : 52 - 59
  • [6] Influence of Scan Resolution, Thresholding, and Reconstruction Algorithm on Computed Tomography-Based Kinematic Measurements
    Tan, Christopher John
    Parr, William C. H.
    Walsh, William R.
    Makara, Mariano
    Johnson, Kenneth A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (10):
  • [7] Cone beam computed tomography-based models versus multislice spiral computed tomography-based models for assessing condylar morphology
    Gomes, Liliane Rosas
    Gomes, Marcelo Regis
    Goncalves, Joao Roberto
    Ruellas, Antonio Carlos O.
    Wolford, Larry M.
    Paniagua, Beatriz
    Benavides, Erika
    Cevidanes, Lucia Helena Soares
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (01): : 96 - 105
  • [8] Multichannel Computed Tomography Versus Cone-Beam Computed Tomography: Linear Accuracy of In Vitro Measurements of the Maxilla for Implant Placement
    Fatemitabar, Seyed Ahmad
    Nikgoo, Arash
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 499 - 505
  • [9] Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
    Suomalainen, A.
    Vehmas, T.
    Kortesniemi, M.
    Robinson, S.
    Peltola, J.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) : 10 - 17
  • [10] Optimal computed tomography-based biomarkers for prediction of incisional hernia formation
    Talwar, A. A.
    Desai, A. A.
    McAuliffe, P. B.
    Broach, R. B.
    Hsu, J. Y.
    Liu, T.
    Udupa, J. K.
    Tong, Y.
    Torigian, D. A.
    Fischer, J. P.
    HERNIA, 2024, 28 (01) : 17 - 24