The accuracy of computed tomography-based linear measurements of human femora and titanium stem

被引:15
作者
Feng, ZD
Ziv, I
Rho, J
机构
[1] SUNY BUFFALO,DEPT ORTHOPAED SURG,BUFFALO,NY 14214
[2] DEPT VET AFFAIRS MED CTR,BUFFALO,NY
关键词
computed tomography; hip arthroplasty; femur; titanium stem; image analysis; profile window; Half-maximum height;
D O I
10.1097/00004424-199606000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS. Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned, Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique, A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images, The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS. Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%), The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS. The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem, The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 18 条
[1]  
BLUMENFELD SM, 1981, RADIOLOGY SKULL BRAI, V5
[2]  
CAPELLO WN, 1989, CLIN ORTHOP RELAT R, V249, P56
[3]  
CHECKLEY DR, 1984, J COMPUT ASSIST TOMO, V8, P237
[4]   THE EFFECTS OF SCATTER IN X-RAY COMPUTED-TOMOGRAPHY [J].
JOSEPH, PM ;
SPITAL, RD .
MEDICAL PHYSICS, 1982, 9 (04) :464-472
[5]  
KOEHLER PR, 1979, RADIOLOGY, V130, P189
[6]  
MICHAEL S, 1994, INT J ORAL MAXILLOF, V9, P455
[7]  
Morgan C. L, 1983, BASIC PRINCIPLES GRA
[8]  
RHO JY, 1995, P AM SOC MECH ENG, V29, P557
[9]   DESIGN OF CUSTOM HIP STEM PROSTHESES USING 3-DIMENSIONAL CT MODELING [J].
ROBERTSON, DD ;
WALKER, PS ;
GRANHOLM, JW ;
NELSON, PC ;
WEISS, PJ ;
FISHMAN, EK ;
MAGID, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :804-809
[10]   EVALUATION OF CT TECHNIQUES FOR REDUCING ARTIFACTS IN THE PRESENCE OF METALLIC ORTHOPEDIC IMPLANTS [J].
ROBERTSON, DD ;
WEISS, PJ ;
FISHMAN, EK ;
MAGID, D ;
WALKER, PS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) :236-241