Adhesion after erbium, chromium:yttrium-scandium-gallium-garnet laser application at three different irradiation conditions

被引:35
作者
Botta, Sergio Brossi [1 ]
da Ana, Patricia Aparecida [2 ]
Zezell, Denise Maria [2 ]
Powers, John M. [3 ]
Matos, Adriana Bona [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Operat Dent, BR-05508000 Sao Paulo, Brazil
[2] IPEN CNEN SP, Ctr Lasers & Applicat, Sao Paulo, Brazil
[3] Univ Texas Houston, Houston Biomat Res Ctr, Dent Branch, Houston, TX USA
基金
巴西圣保罗研究基金会;
关键词
Er; Cr:YSGG laser; Dental hard tissue; Water cooling; Bond strength; MICROTENSILE BOND STRENGTH; ER-YAG-LASER; DENTAL ENAMEL; ER; CR-YSGG; RESIN; WATER; ABLATION; MICROLEAKAGE; SYSTEMS; TEETH;
D O I
10.1007/s10103-007-0521-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate whether distinct cooling of low fluence erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation would influence adhesion. Main factors tested were: substrates (two), irradiation conditions (three), and adhesives (three). A 750 mu m diameter tip was used, for 50 s, 1 mm from the surface, with a 0.25 W power output, 20 Hz, energy density of 2.8 J/cm(2) with energy per pulse of 12.5 mJ. When applied, water delivery rate was 11 ml/min. The analysis of variance (ANOVA) showed that laser conditioning significantly decreased the bond strength of all adhesive systems applied on enamel. On dentin, laser conditioning significantly reduced bond strength of etch-and-rinse and one-step self-etch systems; however, laser irradiation under water cooling did not alter bonding of two-step self-etching. It may be concluded that the irradiation with Er,Cr:YSGG laser at 2.8 J/cm(2) with water coolant was responsible for a better adhesion to dentin, while enamel irradiation reduced bond strength, irrespective of cooling conditions.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 47 条
[1]   Thermal analysis of teeth irradiated with Er,Cr:YSGG at low fluences [J].
Ana, P. A. ;
Way, A. ;
Miyakawa, W. ;
Zezell, D. M. .
LASER PHYSICS LETTERS, 2007, 4 (11) :827-834
[2]   Demineralization of Er:YAG and Er,Cr:YSGG laser-prepared enamel cavities in vitro [J].
Apel, C ;
Schäfer, C ;
Gutknecht, N .
CARIES RESEARCH, 2003, 37 (01) :34-37
[3]  
Apel C, 2000, PROG BIOM O, V1, P318
[4]  
Armstrong SR, 2003, J ADHES DENT, V5, P47
[5]   INVITRO BOND STRENGTH OF CEMENTS TO TREATED TEETH [J].
BARAKAT, MM ;
POWERS, JM .
AUSTRALIAN DENTAL JOURNAL, 1986, 31 (06) :415-419
[6]   Etching enamel for orthodontics with an erbium, chromium:yttrium-scandium-gallium-garnet laser system [J].
Basaran, Guvenc ;
Ozer, Torun ;
Berk, Nukhet ;
Hamamci, Orhan .
ANGLE ORTHODONTIST, 2007, 77 (01) :117-123
[7]  
Besnault C, 2004, J ADHES DENT, V6, P55
[8]  
Borges Gilberto Antonio, 2006, Braz. Dent. J., V17, P186, DOI 10.1590/S0103-64402006000300002
[9]   Bonding to Er-YAG-laser-treated dentin [J].
Ceballos, L ;
Toledano, M ;
Osorio, R ;
Tay, FR ;
Marshall, GW .
JOURNAL OF DENTAL RESEARCH, 2002, 81 (02) :119-122
[10]   Effect of Er:YAG laser on enamel acid resistance:: Morphological and atomic spectrometry analysis [J].
Cecchini, RCM ;
Zezell, DM ;
de Oliveira, E ;
de Freitas, PM ;
Eduardo, CD .
LASERS IN SURGERY AND MEDICINE, 2005, 37 (05) :366-372